ARCHETYPE Audiogram test result (openEHR-EHR-OBSERVATION.audiogram_result.v0)

ARCHETYPE IDopenEHR-EHR-OBSERVATION.audiogram_result.v0
ConceptAudiogram test result
DescriptionMeasurement of hearing acuity using a calibrated hearing test device, and associated clinical interpretation.
UseUse to record measurements and related findings for a single identified test of hearing acuity, for each ear tested separately or both ears simultaneously, via air conduction and/or bone conduction, with masking when required. Use to record the interpretation of all measurements of hearing acuity for each ear or both ears if tested simultaneously, and an overall interpretation (or audiological diagnosis). This archetype has been designed to capture hearing threshold determination for air conduction and/or bone conduction (with or without masking) for the following tests: - Pure Tone Audiometry; - Play Audiometry; - Auditory Brainstem Response; and - Visual Reinforcement Orientation Audiometry. All of the data elements are recorded using a single method or protocol. If, during the test, any of the protocol parameters need to be modified, then the subsequent part of the test will need to be recorded within a separate instance of the test data, using the updated protocol parameters.
MisuseNot to be used for hearing screening assessment - use the OBSERVATION.hearing_screening archetype. Not to be used to record other auditory assessments such as: - Behavioural Observation Audiometry (BOA); - Most Comfortable Listening Level (MCL) and Uncomfortable Listening Level (UCL); and - Auditory Brainstem Response (ABR) for any purpose other than hearing threshold determination. These assessments need to be recorded in specific archetypes for the purpose.
PurposeTo record measurements of hearing acuity using a calibrated hearing test device, and their interpretation by a clinician.
ReferencesDerived from: Audiogram result, Draft archetype [Internet]. Australian Digital Health Agency (NEHTA), ADHA Clinical Knowledge Manager. Authored: 2012 Oct 10. Available at: http://dcm.nehta.org.au/ckm#showArchetype_1013.1.1097_17 (discontinued).

Sabini P, Sclafani AP. Efficacy of serologic testing in asymmetric sensorineural hearing loss. Otolaryngol Head Neck Surg. 2000 Apr;122(4):469-76. PubMed PMID: 10740163.
Copyright© Northern Territory Department of Health (Australia), openEHR Foundation
AuthorsAuthor name: Kerrie Lee
Organisation: Hearing Health Program, Northern Territory
Email: kerrie.lee2@bigpond.com
Date originally authored: 2012-10-10
Other Details LanguageAuthor name: Kerrie Lee
Organisation: Hearing Health Program, Northern Territory
Email: kerrie.lee2@bigpond.com
Date originally authored: 2012-10-10
OtherDetails Language Independent{licence=This work is licensed under the Creative Commons Attribution-ShareAlike 3.0 License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/3.0/., custodian_organisation=openEHR Foundation, references=Derived from: Audiogram result, Draft archetype [Internet]. Australian Digital Health Agency (NEHTA), ADHA Clinical Knowledge Manager. Authored: 2012 Oct 10. Available at: http://dcm.nehta.org.au/ckm#showArchetype_1013.1.1097_17 (discontinued). Sabini P, Sclafani AP. Efficacy of serologic testing in asymmetric sensorineural hearing loss. Otolaryngol Head Neck Surg. 2000 Apr;122(4):469-76. PubMed PMID: 10740163., current_contact=Heather Leslie, Atomica Informatics, Australia, original_namespace=org.openehr, original_publisher=openEHR Foundation, custodian_namespace=org.openehr, MD5-CAM-1.0.1=11B16DFF344B9BDCD3C6DE5524A5617B, build_uid=658c82a0-ff94-4a14-ab9f-86ccdbb2a6b5, revision=0.0.1-alpha}
Keywordshearing, test, audiogram, audiometry, acuity, threshold, decibels, ABR, VROA, VRA, play
Lifecyclein_development
UID90a3a0e4-23f0-49ff-8eae-fa748c7f9a72
Language useden
Citeable Identifier1246.145.2014
Revision Number0.0.1-alpha
AllArchetype [runtimeNameConstraintForConceptName=null, archetypeConceptBinding=null, archetypeConceptDescription=Measurement of hearing acuity using a calibrated hearing test device, and associated clinical interpretation., archetypeConceptComment=null, otherContributors=Amarjit Anand, NT Department of Health/NT Hearing
Judith Boswell, Adelaide Hearing Consultants, Australia
Stephen Chu, NEHTA, Australia
Kimberley Crebbin, NT Hearing Services, Australia
Kathy Currie, Northern Territory Health, Australia
Lisa Dawson, NT Hearing, Northern Territory
Jade Frederiksen, Hearing Health Program, DoH, Australia
Sam Harkus, Australian Hearing, Australia
Sam Heard, Ocean Informatics, Australia (Editor)
Paul Hickey, Hearing Health Program, Australia
Oliver Hosking, Remote Health NT, Australia
Anthony Leech, Hearing Health, Australia
Kerrie Lee, Ngaanyatjarra Health Service, Australia
Heather Leslie, Atomica Informatics, Australia (Editor)
Rebecca Matthews, NT Hearing Services - NTG, Australia
Ian McNicoll, Ocean Informatics UK, United Kingdom
Mark Ramjan, NT Department of Health, Australia
Bojana Sarkic, Northern Territory Government, Australia
Kelly Simmons, Department of Health, Australia
Prasha Sooful, Royal Darwin Hospital, Australia
Fiona Wake, RAHC, Australia, originalLanguage=en, translators=, subjectOfData=unconstrained, archetypeTranslationTree=null, topLevelToAshis={relationships=[], source=[], capabilities=[], activities=[], details=[], context=[], ism_transition=[], other_participations=[], data=[ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0037], code=at0037, itemType=ELEMENT, level=4, text=Test result name, description=Identification of the Audiometry test performed., comment=Coding with an external terminology is preferred, where possible. Applicable tests include: Pure Tone Audiometry; Play Audiometry; Auditory Brainstem Response (for threshold determination); and Visual Reinforcement Orientation Audiometry., uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006], code=at0006, itemType=CLUSTER, level=4, text=Result details, description=The test result measurements and interpretations which can be recorded per ear, or for both ears simultaneously., comment=null, uncommonOntologyItems=null, occurencesFormal=0..3, occurencesText=Optional, cardinalityFormal=2..*, cardinalityText=Minimum of 2 items, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0007], code=at0007, itemType=ELEMENT, level=5, text=Test ear, description=Identification of the ear(s) to which the test stimulus is being presented., comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Right ear [The test stimuli were presented to the right ear only.]
  • Left ear [The test stimuli were presented to the left ear only.]
  • Binaural [The test stimuli were presented to both ears simultaneously in a soundfield.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0139], code=at0139, itemType=CLUSTER, level=5, text=Air conduction result, description=The thresholds obtained using air conduction testing., comment=null, uncommonOntologyItems=null, occurencesFormal=0..2, occurencesText=Optional, cardinalityFormal=1..*, cardinalityText=, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0139]/items[at0141], code=at0141, itemType=ELEMENT, level=6, text=Air conduction masking, description=A masking stimulus was applied to the non-test ear to obtain specified air conduction thresholds., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_BOOLEAN, bindings=null, values=Allowed values: {true}, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0139]/items[at0048], code=at0048, itemType=CLUSTER, level=6, text=Measurement, description=The measured frequency/threshold dB level pair for air conduction results., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=2..2, cardinalityText=Minimum of 2 items, maximum of 2 items, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0139]/items[at0048]/items[at0011], code=at0011, itemType=ELEMENT, level=7, text=Frequency, description=The stimulus frequency tested., comment=Frequency is not applicable if a click stimulus is presented., uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=null, values=Property: Frequency
Units:
  • 125.0..16000.0 Hz
    Limit decimal places: 0
  • 0.125..16.0 kHz
    Limit decimal places: 3
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0139]/items[at0048]/items[at0012], code=at0012, itemType=ELEMENT, level=7, text=Threshold level, description=The stimulus intensity at threshold for the test frequency., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=null, values=Property: Loudness
Units: -10.0..120.0 dB
Limit decimal places: 0

Possible reasons why null:
  • unknown
  • masked
  • not applicable
  • no information
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0139]/items[at0048]/items[at0153], code=at0153, itemType=ELEMENT, level=7, text=No response, description=No response from subject at identified frequency., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_BOOLEAN, bindings=null, values=Allowed values: {true}, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0139]/items[at0122], code=at0122, itemType=ELEMENT, level=6, text=No test result, description=No air conduction test result is available for the test ear., comment=Record as True if the clinician was unable to record a result for the test ear or binaural testing in a soundfield, as defined by the 'Test Ear' data element., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_BOOLEAN, bindings=null, values=Allowed values: {true}, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0139]/items[at0123], code=at0123, itemType=ELEMENT, level=6, text=Reason for no result, description=Reason why no air conduction result is available for the test ear., comment=For example, patient was not cooperative; patient was not capable; ran out of time., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0140], code=at0140, itemType=CLUSTER, level=5, text=Bone conduction result, description=The thresholds obtained using bone conduction testing., comment=null, uncommonOntologyItems=null, occurencesFormal=0..2, occurencesText=Optional, cardinalityFormal=1..*, cardinalityText=, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0140]/items[at0142], code=at0142, itemType=ELEMENT, level=6, text=Bone conduction masking, description=A masking stimulus was applied to the non-test ear to obtain specified bone conduction thresholds., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_BOOLEAN, bindings=null, values=Allowed values: {true}, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0140]/items[at0143], code=at0143, itemType=CLUSTER, level=6, text=Measurement, description=The measured frequency/threshold dB level pair for bone conduction results., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=1..*, cardinalityText=, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0140]/items[at0143]/items[at0144], code=at0144, itemType=ELEMENT, level=7, text=Frequency, description=The stimulus frequency of the test signal., comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=null, values=Property: Frequency
Units:
  • 125.0..16000.0 Hz
    Limit decimal places: 0
  • 0.125..16.0 kHz
    Limit decimal places: 3
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0140]/items[at0143]/items[at0145], code=at0145, itemType=ELEMENT, level=7, text=Threshold level, description=The intensity of the test stimulus at the subject's threshold for the test frequency., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=null, values=Property: Loudness
Units: -10.0..120.0 dB
Limit decimal places: 0, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0140]/items[at0143]/items[at0154], code=at0154, itemType=ELEMENT, level=7, text=No response, description=No response from subject at identified frequency., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_BOOLEAN, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0140]/items[at0146], code=at0146, itemType=ELEMENT, level=6, text=No test result, description=No bone conduction test result is available for the test ear., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_BOOLEAN, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0140]/items[at0147], code=at0147, itemType=ELEMENT, level=6, text=Reason for no result, description=Reason why no bone conduction result is available for the test ear., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0055], code=at0055, itemType=CLUSTER, level=5, text=Hearing threshold interpretation, description=Interpretation of a series of audiometric measurements for purposes of hearing threshold assessment., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=1..*, cardinalityText=, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0055]/items[at0056], code=at0056, itemType=ELEMENT, level=6, text=Pure tone average, description=The average pure tone threshold according to the specified averaging criteria., comment=This calculation is typically determined using air conduction thresholds., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=null, values=Property: Loudness
Units: -10.0..120.0 dB
Limit decimal places: 1, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0055]/items[at0135], code=at0135, itemType=ELEMENT, level=6, text=Degree of loss, description=Category of the degree of hearing loss derived from the dB threshold values using specified criteria., comment=Coding with a terminology is desirable, where possible. For example: none, mild, moderate, severe and profound. Each of these categories should be clearly defined on the basis of a dB range appropriate for age., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0055]/items[at0065], code=at0065, itemType=ELEMENT, level=6, text=Type of loss, description=Identified type of hearing loss for the test ear, based on all measurements., comment=If there is no degree of loss, then this data element is not applicable., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Conductive [A conductive hearing loss pattern has been identified for the Test Ear, based on the presence of an air/bone gap and bone conduction thresholds within normal range.]
  • Sensorineural [A sensorineural hearing loss pattern has been identified for the Test Ear, based on no air/bone gap and thresholds outside normal range.]
  • Retrocochlear [A form of sensorineural hearing loss in which the lesion is proximal to the cochlear.]
  • Mixed [A mixed hearing loss pattern has been identified for the Test Ear, based on the presence of an air/bone gap and bone conduction thresholds outside normal range.]
  • Indeterminate [It is not possible to determine the pattern of hearing loss.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0055]/items[at0070], code=at0070, itemType=ELEMENT, level=6, text=Clinical interpretation, description=Clinical interpretation of all measurements for the test ear., comment=Coding with a terminology is preferred, where possible. Not to be used for recording the interpretation for both ears when the ears are tested simultaneously - use the data element 'Overall Interpretation' instead., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0055]/items[at0126], code=at0126, itemType=ELEMENT, level=6, text=Articulation index, description=An algorithm to predict the amount of speech that is audible to a patient with a specific hearing loss., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_PROPORTION, bindings=null, values=
  • Unitary
Numerator: 0.0..1.0
Assumed value: false
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0006]/items[at0055]/items[at0166], code=at0166, itemType=ELEMENT, level=6, text=Comment, description=Additional narrative about the hearing threshold interpretation not captured in other fields., comment=For example: to explain the reason why a degree of loss has been recorded that appears to deviate from the protocol for the corresponding pure tone average., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0071], code=at0071, itemType=ELEMENT, level=4, text=Sensorineural symmetry, description=An interpretation about the symmetry of sensorineural component of hearing loss, based on bone conduction measurements for both ears., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Symmetrical [The hearing loss is symmetrical.]
  • Asymmetrical [The hearing loss is asymmetrical.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0131], code=at0131, itemType=ELEMENT, level=4, text=Laterality of loss, description=An interpretation about the laterality of hearing loss, based on all hearing acuity measurements for both ears., comment=If there is no degree of loss in both ears, then this data element is not applicable., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Unilateral [Loss of hearing in one ear.]
  • Bilateral [Loss of hearing in both ears.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0165], code=at0165, itemType=ELEMENT, level=4, text=Degree of impairment, description=Category of the degree of overall hearing impairment derived from the dB threshold values using specified criteria based on the better hearing ear., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0167], code=at0167, itemType=SLOT, level=4, text=Multimedia, description=Digital representation of the test results., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include:
openEHR-EHR-CLUSTER.multimedia.v1 and specialisations, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0121], code=at0121, itemType=ELEMENT, level=4, text=Overall interpretation, description=Overall clinical interpretation of the measurements and related findings using an audiometer., comment=Coding with a terminology is preferred, where possible. This data element is effectively an audiological diagnosis. Binaural test results reflect either the performance for both ears (if equal hearing) or only the better ear (where the hearing is not symmetrical)., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0172], code=at0172, itemType=SLOT, level=4, text=Test not done, description=Details to explicitly record that this test was not performed., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include:
openEHR-EHR-CLUSTER.exclusion_exam.v1 and specialisations, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/data[at0003]/items[at0027], code=at0027, itemType=ELEMENT, level=4, text=Comment, description=Additional narrative about the test results and intepretation not captured in other fields., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null]], credentials=[], target=[], items=[], content=[], description=[], contacts=[], state=[ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/state[at0013]/items[at0028], code=at0028, itemType=ELEMENT, level=4, text=Aided status, description=Indication regarding use of an assistive listening device by the test subject during the test., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Unaided [Testing has not been aided by a hearing device, such as a hearing aid or cochlear implant.]
  • Right aided [Right ear testing has been aided by a hearing device, such as a hearing aid or cochlear implant.]
  • Left aided [Left ear testing has been aided by a hearing device, such as a hearing aid or cochlear implant.]
  • Bilateral aided [Testing has been aided by use of bilateral hearing devices, such as a hearing aids or cochlear implants.]
  • Bone conduction aided [Testing has been aided by a bone conduction device.]

Assumed value: Unaided, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002]/state[at0013]/items[at0164], code=at0164, itemType=ELEMENT, level=4, text=Confounding factors, description=Narrative description of factors, not recorded elsewhere, that may influence the threshold measurements., comment=For example: noise exposure prior to test., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null]], events=[ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0002], code=at0002, itemType=POINT_EVENT, level=2, text=Any point in time event, description=Default, unspecified point in time which may be explicitly defined in a template or at run-time. For example, in a template, this event can be cloned and specifically identified to be the first and/or second test conducted as a part of a comprehensive assessment, such as a Hearing Conservation or Industrial Audiometric Assessment., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=POINT_EVENT, bindings=null, values=null, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0163], code=at0163, itemType=INTERVAL_EVENT, level=2, text=Average, description=Record of the average measured results from more than one test. For example, the average of the 3000Hz to 6000Hz measurements in a Hearing Conservation or Industrial Audiometry Assessment. The data elements required in this use case may be quite limited and relevant ones revealed via templating., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=INTERVAL_EVENT, bindings=null, values=Math. function: Median
, extendedValues=null]], provider=[], identities=[], protocol=[ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0171], code=at0171, itemType=SLOT, level=2, text=Extension, description=Additional information required to capture local content or to align with other reference models/formalisms., comment=For example: local information requirements or additional metadata to align with FHIR or CIMI equivalents., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include:
All not explicitly excluded archetypes, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0109], code=at0109, itemType=ELEMENT, level=2, text=Air presentation, description=Presentation of the air conduction test stimulus indirectly to the inner ear through the atmosphere, via the auditory canal and middle ear structures., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Soundfield [The stimulus is presented via a loudspeaker located at least one metre away from the subject.]
  • Insert earphone [The stimulus is presented via insert earphones.]
  • Headphones [The stimulus is presented via external headphones - either circumaural or supraaural.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0113], code=at0113, itemType=ELEMENT, level=2, text=Bone presentation, description=Presentation of the bone conduction test stimulus directly to the inner ear via the cranial bones., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Mastoid [The posterior part of the temporal bone, including the mastoid process.]
  • Forehead [Area of the head bounded by the normal hairline, eyebrows and the temples on either side.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0075], code=at0075, itemType=ELEMENT, level=2, text=Test environment, description=The environment in which the audiometric test is administered., comment=This data element is commonly used in industry hearing programs., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Audiometric booth [Sound-treated test environment that meets audiometric standards for ambient noise.]
  • Non-sound treated room [Test environment that does not meet audiometric standards for ambient noise.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0157], code=at0157, itemType=ELEMENT, level=2, text=Background noise, description=The amount and nature of noise in the environment that may influence the test results., comment=If testing is conducted in an audiometric booth, this data element is redundant., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Clinically significant [The background noise may compromise test results.]
  • Not clinically significant [The background noise is not likely to compromise test results.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0034], code=at0034, itemType=ELEMENT, level=2, text=Test stimulus, description=Identification of the stimulus used in the hearing test to measure the hearing threshold., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Tone burst [The test stimulus is a tone burst.]
  • Click [The test stimulus is a click.]
  • Warble Tone [The test stimulus is a frequency modulated tone.]
  • Pure Tone [The test stimulus is a pure tone.]
  • Narrow Band Noise [The test stimulus is a narrow band noise centred on the specified frequency.]
  • Pulse tone [The test stimulus is a pulse tone.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0085], code=at0085, itemType=CLUSTER, level=2, text=Click stimulus specification, description=Identification of parameters specifying a click stimulus., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=1..*, cardinalityText=, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0085]/items[at0086], code=at0086, itemType=ELEMENT, level=3, text=Onset ramp, description=Time over which the stimulus grows to full amplitude., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=null, values=Property: Time
Units: ms, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0085]/items[at0087], code=at0087, itemType=ELEMENT, level=3, text=Offset ramp, description=Time over which the stimulus depletes to zero amplitude., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=null, values=Property: Time
Units: ms, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0085]/items[at0088], code=at0088, itemType=ELEMENT, level=3, text=Total duration, description=Total duration of the click stimulus., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=null, values=Property: Time
Units: ms, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0093], code=at0093, itemType=CLUSTER, level=2, text=Threshold determination protocol, description=Protocol used to measure the hearing threshold for pure tone, play and visual reinforcement orientation audiometry only., comment=Not applicable for ABR testing., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=1..*, cardinalityText=, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0093]/items[at0127], code=at0127, itemType=ELEMENT, level=3, text=Threshold definition, description=Definition of the protocol used to define the threshold level used in the test., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Minimum response level [The softest level at which a subject responds to a stimulus.]
  • 2/3 responses [The softest level at which the subject responds to two out of three consecutive threshold runs.]
  • 3/6 responses [The softest level at which the subject responds to three out of six consecutive threshold runs.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0093]/items[at0094], code=at0094, itemType=ELEMENT, level=3, text=Step size, description=The step size (in decibels) of the change in the stimulus intensity for threshold determination., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • 1 dB [Step size of one decibel.]
  • 5 dB [Step size of five decibels.]
  • 10 dB [Step size of ten decibels.]
  • 20 dB [Step size of twenty decibels.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0093]/items[at0099], code=at0099, itemType=ELEMENT, level=3, text=Direction, description=The direction of change in the stimulus intensity., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Ascending [Threshold is calculated based on the ascending runs where the stimulus moves from below threshold to above threshold.]
  • Descending [Threshold is calculated based on the descending runs where the stimulus moves from above threshold to below threshold.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0047], code=at0047, itemType=SLOT, level=2, text=Test instrument, description=Details of device used to conduct the test., comment=Details of the headphones and bone conductors that are calibrated to be used in conjunction with a specific hearing test instrument will be nested as specific CLUSTER archetypes within the CLUSTER.hearing_test_instrument archetype., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include:
openEHR-EHR-CLUSTER.device.v1 and specialisations, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0149], code=at0149, itemType=SLOT, level=2, text=Hearing device, description=Details of the hearing device used., comment=For example: hearing aid or bone conductor aid., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include:
openEHR-EHR-CLUSTER.device.v1 and specialisations, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0134], code=at0134, itemType=ELEMENT, level=2, text=Reliability, description=Narrative description of the reliability of the test results., comment=If an appropriate value set can be determined, this could be coded. The maximum occurrences of this data element have been set to two to allow for both narrative and a coded value to be selected in a template., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0119], code=at0119, itemType=ELEMENT, level=2, text=Test modifications required, description=Narrative description of any modfications to the standard methodology required to enable successful completion of the test., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0089], code=at0089, itemType=ELEMENT, level=2, text=Calibration reference dB, description=Scale used for acoustic calibration of the test signal., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • dB SPL [The test stimuli are calibrated using the sound pressure level scale.]
  • dB HL [The test stimuli are calibrated using the hearing level scale.]
  • dB nHL [The test stimuli are calibrated using the normal hearing level scale.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0061], code=at0061, itemType=ELEMENT, level=2, text=Criteria for pure tone average, description=The criteria on which the Pure Tone Average is calculated. The average is based on air conduction thresholds and masked thresholds replace unmasked thresholds when applying the formula., comment=If recording the Criteria as a narrative, it is possible to identify the frequencies used for non-standard Pure Tone Average as free text., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CHOICE, bindings=null, values=Choice of:
  •  Coded Text
    • 3 frequency average [The pure tone hearing threshold is calculated using 0.5, 1 and 2 kHz.]
    • 4 frequency average [The pure tone hearing threshold is calculated using 0.5, 1, 2 and 4 kHz.]
  •  Text
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0138], code=at0138, itemType=ELEMENT, level=2, text=Criteria for asymmetry, description=The criteria on which asymmetry is defined in the test result interpretation., comment=For example: binaural difference in bone conduction thresholds of >10 dB at two consecutive frequencies or >15 dB at one frequency (0.25–8.0 kHz)., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0120], code=at0120, itemType=ELEMENT, level=2, text=Comment, description=Additional narrative about the protocol for the audiogram not captured in other fields., comment=For example, the co-operation of the test subject or description of the method used for testing., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null]]}, topLevelItems={data=ResourceSimplifiedHierarchyItem [path=ROOT_/data[at0001]/events[at0002]/data[at0003], code=at0003, itemType=ITEM_TREE, level=2, text=null, description=null, comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=0..1, cardinalityText=optional, subCardinalityFormal=1..*, subCardinalityText=, dataType=ITEM_TREE, bindings=null, values=null, extendedValues=null], state=ResourceSimplifiedHierarchyItem [path=ROOT_/data[at0001]/events[at0002]/state[at0013], code=at0013, itemType=ITEM_TREE, level=2, text=null, description=null, comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=0..1, cardinalityText=optional, subCardinalityFormal=0..*, subCardinalityText=Minimum of 0 items, dataType=ITEM_TREE, bindings=null, values=null, extendedValues=null], protocol=ResourceSimplifiedHierarchyItem [path=ROOT_/protocol[at0032], code=at0032, itemType=ITEM_TREE, level=0, text=null, description=null, comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=0..1, cardinalityText=optional, subCardinalityFormal=0..*, subCardinalityText=Minimum of 0 items, dataType=ITEM_TREE, bindings=null, values=null, extendedValues=null]}, addHierarchyItemsTo=protocol, currentHierarchyItemsForAdding=[ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0171], code=at0171, itemType=SLOT, level=2, text=Extension, description=Additional information required to capture local content or to align with other reference models/formalisms., comment=For example: local information requirements or additional metadata to align with FHIR or CIMI equivalents., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include:
All not explicitly excluded archetypes, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0109], code=at0109, itemType=ELEMENT, level=2, text=Air presentation, description=Presentation of the air conduction test stimulus indirectly to the inner ear through the atmosphere, via the auditory canal and middle ear structures., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Soundfield [The stimulus is presented via a loudspeaker located at least one metre away from the subject.]
  • Insert earphone [The stimulus is presented via insert earphones.]
  • Headphones [The stimulus is presented via external headphones - either circumaural or supraaural.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0113], code=at0113, itemType=ELEMENT, level=2, text=Bone presentation, description=Presentation of the bone conduction test stimulus directly to the inner ear via the cranial bones., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Mastoid [The posterior part of the temporal bone, including the mastoid process.]
  • Forehead [Area of the head bounded by the normal hairline, eyebrows and the temples on either side.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0075], code=at0075, itemType=ELEMENT, level=2, text=Test environment, description=The environment in which the audiometric test is administered., comment=This data element is commonly used in industry hearing programs., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Audiometric booth [Sound-treated test environment that meets audiometric standards for ambient noise.]
  • Non-sound treated room [Test environment that does not meet audiometric standards for ambient noise.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0157], code=at0157, itemType=ELEMENT, level=2, text=Background noise, description=The amount and nature of noise in the environment that may influence the test results., comment=If testing is conducted in an audiometric booth, this data element is redundant., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Clinically significant [The background noise may compromise test results.]
  • Not clinically significant [The background noise is not likely to compromise test results.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0034], code=at0034, itemType=ELEMENT, level=2, text=Test stimulus, description=Identification of the stimulus used in the hearing test to measure the hearing threshold., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Tone burst [The test stimulus is a tone burst.]
  • Click [The test stimulus is a click.]
  • Warble Tone [The test stimulus is a frequency modulated tone.]
  • Pure Tone [The test stimulus is a pure tone.]
  • Narrow Band Noise [The test stimulus is a narrow band noise centred on the specified frequency.]
  • Pulse tone [The test stimulus is a pulse tone.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0085], code=at0085, itemType=CLUSTER, level=2, text=Click stimulus specification, description=Identification of parameters specifying a click stimulus., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=1..*, cardinalityText=, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0085]/items[at0086], code=at0086, itemType=ELEMENT, level=3, text=Onset ramp, description=Time over which the stimulus grows to full amplitude., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=null, values=Property: Time
Units: ms, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0085]/items[at0087], code=at0087, itemType=ELEMENT, level=3, text=Offset ramp, description=Time over which the stimulus depletes to zero amplitude., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=null, values=Property: Time
Units: ms, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0085]/items[at0088], code=at0088, itemType=ELEMENT, level=3, text=Total duration, description=Total duration of the click stimulus., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=null, values=Property: Time
Units: ms, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0093], code=at0093, itemType=CLUSTER, level=2, text=Threshold determination protocol, description=Protocol used to measure the hearing threshold for pure tone, play and visual reinforcement orientation audiometry only., comment=Not applicable for ABR testing., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=1..*, cardinalityText=, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0093]/items[at0127], code=at0127, itemType=ELEMENT, level=3, text=Threshold definition, description=Definition of the protocol used to define the threshold level used in the test., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Minimum response level [The softest level at which a subject responds to a stimulus.]
  • 2/3 responses [The softest level at which the subject responds to two out of three consecutive threshold runs.]
  • 3/6 responses [The softest level at which the subject responds to three out of six consecutive threshold runs.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0093]/items[at0094], code=at0094, itemType=ELEMENT, level=3, text=Step size, description=The step size (in decibels) of the change in the stimulus intensity for threshold determination., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • 1 dB [Step size of one decibel.]
  • 5 dB [Step size of five decibels.]
  • 10 dB [Step size of ten decibels.]
  • 20 dB [Step size of twenty decibels.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0093]/items[at0099], code=at0099, itemType=ELEMENT, level=3, text=Direction, description=The direction of change in the stimulus intensity., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Ascending [Threshold is calculated based on the ascending runs where the stimulus moves from below threshold to above threshold.]
  • Descending [Threshold is calculated based on the descending runs where the stimulus moves from above threshold to below threshold.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0047], code=at0047, itemType=SLOT, level=2, text=Test instrument, description=Details of device used to conduct the test., comment=Details of the headphones and bone conductors that are calibrated to be used in conjunction with a specific hearing test instrument will be nested as specific CLUSTER archetypes within the CLUSTER.hearing_test_instrument archetype., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include:
openEHR-EHR-CLUSTER.device.v1 and specialisations, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0149], code=at0149, itemType=SLOT, level=2, text=Hearing device, description=Details of the hearing device used., comment=For example: hearing aid or bone conductor aid., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Include:
openEHR-EHR-CLUSTER.device.v1 and specialisations, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0134], code=at0134, itemType=ELEMENT, level=2, text=Reliability, description=Narrative description of the reliability of the test results., comment=If an appropriate value set can be determined, this could be coded. The maximum occurrences of this data element have been set to two to allow for both narrative and a coded value to be selected in a template., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0119], code=at0119, itemType=ELEMENT, level=2, text=Test modifications required, description=Narrative description of any modfications to the standard methodology required to enable successful completion of the test., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0089], code=at0089, itemType=ELEMENT, level=2, text=Calibration reference dB, description=Scale used for acoustic calibration of the test signal., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • dB SPL [The test stimuli are calibrated using the sound pressure level scale.]
  • dB HL [The test stimuli are calibrated using the hearing level scale.]
  • dB nHL [The test stimuli are calibrated using the normal hearing level scale.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0061], code=at0061, itemType=ELEMENT, level=2, text=Criteria for pure tone average, description=The criteria on which the Pure Tone Average is calculated. The average is based on air conduction thresholds and masked thresholds replace unmasked thresholds when applying the formula., comment=If recording the Criteria as a narrative, it is possible to identify the frequencies used for non-standard Pure Tone Average as free text., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CHOICE, bindings=null, values=Choice of:
  •  Coded Text
    • 3 frequency average [The pure tone hearing threshold is calculated using 0.5, 1 and 2 kHz.]
    • 4 frequency average [The pure tone hearing threshold is calculated using 0.5, 1, 2 and 4 kHz.]
  •  Text
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0138], code=at0138, itemType=ELEMENT, level=2, text=Criteria for asymmetry, description=The criteria on which asymmetry is defined in the test result interpretation., comment=For example: binaural difference in bone conduction thresholds of >10 dB at two consecutive frequencies or >15 dB at one frequency (0.25–8.0 kHz)., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0032]/items[at0120], code=at0120, itemType=ELEMENT, level=2, text=Comment, description=Additional narrative about the protocol for the audiogram not captured in other fields., comment=For example, the co-operation of the test subject or description of the method used for testing., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Optional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null]], minIndents={}, termBindingRetrievalErrorMessage=null]