| ARCHETYPE ID | openEHR-EHR-OBSERVATION.pure_tone_audiogram.v0 |
|---|---|
| Concept | pure tone audiogram |
| Description | pure tone audiogram |
| Purpose | |
| References | |
| Authors | Date originally authored: 2024-02-19 |
| Other Details Language | Date originally authored: 2024-02-19 |
| Other Details (Language Independent) |
|
| Keywords | |
| Lifecycle | in_development |
| UID | 9778a118-6faa-4c7f-9632-b763a371ed97 |
| Language used | en |
| Citeable Identifier | 1246.145.2177 |
| Revision Number | 0.0.1-alpha |
| protocol | |
| Modality | Modality:
|
| Tested Side | Tested Side:
|
| Signal Sources | Signal Sources: Stimulus properties (e.g., test or masking stimulus). If masked threshold is measured, this cluster occures twice in template for stimulus and masker. |
| Device | Device: Description of the signal source used for stimulation
|
| Stimulus | Stimulus: Identification of the stimulus used in the hearing test to measure the hearing threshold.
|
| Position | Position:
|
| Comment | Comment: Additional narrative about the test results and intepretation not captured in other fields. |
| Hearing Devices | Hearing Devices: Hearing devices active during measurement. In template: repeat for all hearing devices of the patient (activated during measurement). |
| Device Type | Device Type:
|
| Position | Position:
|
| Comment | Comment: Additional narrative about the test results and intepretation not captured in other fields. E.g., programs/fittings of HA or CI used during measurement. |
| Test environment | Test environment: The environment in which the audiometric test is administered. This data element is commonly used in industry hearing programs.
|
| Calibration reference dB | Calibration reference dB: Scale used for acoustic calibration of the test signal.
|
| Comment | Comment: Additional narrative about the protocol for the audiogram not captured in other fields. For example, the co-operation of the test subject or description of the method used for testing. |
| data | |
| Spectrum | |
| Frequency | Frequency: The stimulus frequency tested. Frequency is not applicable if a click stimulus is presented. Property: Frequency Units:
|
| Signal Level | Signal Level: The stimulus intensity at threshold for the test frequency. Property: Loudness Units: -10.0..120.0 dB Limit decimal places: 0 |
| Response | Response:
|
| Masking Level | Masking Level: The stimulus intensity at threshold for the test frequency. Property: Loudness Units: -10.0..120.0 dB Limit decimal places: 0 Possible reasons why null:
|
| events | |
| Any event | Any event: @ internal @ |