ARCHETYPE Waveform (openEHR-EHR-CLUSTER.waveform.v0)

ARCHETYPE IDopenEHR-EHR-CLUSTER.waveform.v0
ConceptWaveform
DescriptionA waveform of an equidistant series of time spaced measurements e.g. from a pulse oximeter.
UseUsed within an OBSERVATION archetype e.g. OBSERVATION.heart_rate-pulse or OBSERVATION.indirect_oximetry. Details of the waveform start time and duration/interval should be stored in the parent OBSERVATION. May be used to assess the quality of a measurement, as using a pulse plesmythography waveform to assess the accuracy of a pulse oximetry SpO2 measurement. May also be used as part of a direct patient assessment, e.g. using a pulse plesmythography waveform for cardiac output estimation.
MisuseShould not normally be used other than within an OBSERVATION archetype.
PurposeTo record a series of equidistant time-spaced observations that can be represented as a waveform e.g. a pulse plesmythography waveform from a pulse oximeter.
ReferencesMichard F. Using Pulse Oximetry Waveform Analysis to Guide Fluid Therapy: Are We There Yet? [Internet]. Anesth Analg 2007 Jun;104(6):1606-1607.[cited 2010 Feb 3 ]
Available from: http://www.anesthesia-analgesia.org

Jubran A. Pulse oximetry [Internet]. Critical Care 1999;3(2):R11-R17.[cited 2009 Oct 29 ]
Available from: http://ccforum.com

HL7 International, Implementation Guide for CDA Release 2.0 Personal Healthcare Monitoring Report (PHMR) (International Realm) Draft Standard for Trial Use Release 1. 2008;[cited 2010 Feb 2 ]
Copyright© openEHR Foundation
AuthorsAuthor name: Dr Ian McNicoll
Organisation: Ocean Informatics, United Kingdom
Email: ian.mcnicoll@oceaninformatics.com
Date originally authored: 2010-01-28
Other Details LanguageAuthor name: Dr Ian McNicoll
Organisation: Ocean Informatics, United Kingdom
Email: ian.mcnicoll@oceaninformatics.com
Date originally authored: 2010-01-28
Other Details (Language Independent)
  • Licence: This work is licensed under the Creative Commons Attribution-ShareAlike 3.0 License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/3.0/.
  • Custodian Organisation: openEHR Foundation
  • References: Michard F. Using Pulse Oximetry Waveform Analysis to Guide Fluid Therapy: Are We There Yet? [Internet]. Anesth Analg 2007 Jun;104(6):1606-1607.[cited 2010 Feb 3 ] Available from: http://www.anesthesia-analgesia.org Jubran A. Pulse oximetry [Internet]. Critical Care 1999;3(2):R11-R17.[cited 2009 Oct 29 ] Available from: http://ccforum.com HL7 International, Implementation Guide for CDA Release 2.0 Personal Healthcare Monitoring Report (PHMR) (International Realm) Draft Standard for Trial Use Release 1. 2008;[cited 2010 Feb 2 ]
  • Original Namespace: org.openehr
  • Original Publisher: openEHR Foundation
  • Custodian Namespace: org.openehr
  • MD5-CAM-1.0.1: FE339E15DAFA5073B42CEF6C836D04E4
  • Build Uid: 9f1d918e-f020-4bee-9cdf-4b83a9b47dd0
  • Revision: 0.0.1-alpha
Keywordsoximeter, plesmythography, plesmythogram, pulse, oximetry
Lifecyclein_development
UID03dd65b9-1b74-426d-9df8-841b9f91001d
Language useden
Citeable Identifier1246.145.2851
Revision Number0.0.1-alpha
items
Waveform nameWaveform name: The name of the waveform e.g. pulse plesmythograph.
Waveform imageWaveform image: The waveform as an image or other multimedia/binary type.
Sample periodSample period: The time between individual data points in the waveform.
>=0 seconds
Waveform observationWaveform observation: Multiple waveform observations.
OriginOrigin: The origin of the waveform (typically 0).
Property: null
Scaling factorScaling factor: The scaling factor of the waveform observation.
Property: null
Digits seriesDigits series: Inividual data points of a waveform as defined by the CDA-Continua Alliance PHMR documentation.
Other contributors
Translators
  • Norwegian Bokmål: Lars Bitsch-Larsen, Haukeland University Hospital of Bergen, Norway, MD, DEAA, MBA, spec in anesthesia, spec in tropical medicine.
  • Arabic (Syria): Mona Saleh