Type: openEHR ARCHETYPE
Purpose: To record the objective and quantitative measurement results or observations of any environmental parameter obtained by some sensor, device or monitoring station.
Use:
Use to record quantitative results of environmental components measured by some sensor, device or monitoring station.
Examples include but are not limited to:
Not to be used for:
| ARCHETYPE ID | openEHR-EHR-OBSERVATION.environmental_measurement.v0 |
|---|---|
| Concept | Environmental Measurement |
| Description | Quantitative measurement of an environmental parameter. |
| Use | Use to record quantitative results of environmental components measured by some sensor, device or monitoring station.
|
| Misuse | Not to be used for:
|
| Purpose | To record the objective and quantitative measurement results or observations of any environmental parameter obtained by some sensor, device or monitoring station. |
| References | Derived from: PR-418 on international CKM https://ckm.openehr.org/ckm/archetypeproposals/1013.38.418 |
| Copyright | © HiGHmed |
| Authors | Author name: Adrian Neubauer Organisation: BIH @ Charité - Berlin Institute of Health Email: adrian.neubauer@bih-charite.de Date originally authored: 2026-03-05 |
| Other Details Language | Author name: Adrian Neubauer Organisation: BIH @ Charité - Berlin Institute of Health Email: adrian.neubauer@bih-charite.de Date originally authored: 2026-03-05 |
| Other Details (Language Independent) |
|
| Keywords | environment, air quality, pollution, pollutant, exposure, weather, measurement |
| Lifecycle | in_development |
| UID | 2ca0c76a-329f-4c0b-8979-f4c6a37ab74f |
| Language used | en |
| Citeable Identifier | 1246.145.3097 |
| Revision Number | 0.0.1-alpha |
| protocol | |
| Device / station details | Device / station details: Details of the measuring device used or the measuring station that recorded the measurement result. Using the openEHR-EHR-CLUSTER.device.v1 archetype, for example, the name, properties, and other information regarding the measuring device or measuring station can be recorded. Slot archetypes This slot is open to all Cluster archetypes. |
| Extension | Extension: Additional information required to capture local content or to align with other reference models/formalisms. For example: local information requirements or additional metadata to align with FHIR or CIMI equivalents. Slot archetypes This slot is open to all Cluster archetypes. |
| data | |
| Component | Component: Identifies the environmental parameter being measured or observed. For example PM10, PM2.5, ozone, temperature, relative humidity, or CO₂ concentration. Coding with an external terminology is recommended. Choice of:
|
| Measurement result | Measurement result: Quantitative value of the environmental measurement. For example "11.0 µg/m³". The reference model of this data type includes attributes for accuracy, reference ranges and normal status. |
| Description | Description: Narrative description of the environmental measurement or observation. May be used to provide additional information that is not represented by the other data elements. |
| Environmental domain | Environmental domain: Defines the broad environmental domain to which the measurement belongs. Examples include air quality, weather, noise, and water quality. Coding with an external terminology is recommended. Choice of:
|
| Environment | Environment: Defines the environmental setting or context in which the measurement was obtained. For example, it can be used to record whether the measurement has taken place in an indoor or outdoor environment, or the setting in which the measurement was performed, such as at home or in the workplace. Coding with an external terminology is recommended. Choice of:
|
| Interpretation | Interpretation: Single word, phrase or brief description that represents the qualitative or interpretive assessment of the environmental measurement, where applicable. For example, "unremarkable", "critical", or "no relevant burden." etc. Coding with an external terminology is recommended. Choice of:
|
| Environmental details | Environmental details: Can be used to record additional information describing the environmental context of the measurement. For example, ambient temperature or atmospheric pressure at the time of measurement can be recorded using the "Environmental conditions" CLUSTER archetype. Slot archetypes This slot is open to all Cluster archetypes. |
| events | |
| Any event | Any event: Default, unspecified point in time or interval event which may be explicitly defined in a template or at run-time. |
| Other contributors | Maximilian Meixner, BIH @ Charité - Berlin Institute of Health Severin Kohler, BIH @ Charité - Berlin Institute of Health |
| Translators |