archetype (adl_version=1.4; uid=3cf56d7a-2953-4a9f-9e7c-34cd0653c1d3) openEHR-EHR-OBSERVATION.categorical_loudness_scaling.v0 concept [at0000] -- Categorical loudness scaling language original_language = <[ISO_639-1::en]> description original_author = < ["name"] = <"Lena Schell-Majoor"> ["organisation"] = <"University of Oldenburg, Cluster of Excellence Hearing4all"> ["email"] = <"lena.schell-majoor@uni-oldenburg.de"> ["date"] = <"2023-03-23"> > details = < ["en"] = < language = <[ISO_639-1::en]> purpose = <"To record responses to loudness scaling tests and calculate respective individual loudness growth functions."> use = <"Use to record responses to loudness scaling procedures with or without using hearing aids."> keywords = <"hearing, test, loudness, scaling,", ...> misuse = <" Not to be used for hearing threshold, audiogram or speech understanding assessment Not to be used to record other auditory assessments such as: - Behavioural Observation Audiometry (BOA); - Auditory Brainstem Response (ABR) for diagnostic purposes - Transient Evoked Otoacoustic Emission (TEOAE); and - Distortion Product Otoacoustic Emission (DPOAE). These assessments need to be recorded in specific archetypes for the purpose."> copyright = <"© openEHR Foundation, HiGHmed, Hearing4all"> > > lifecycle_state = <"in_development"> other_contributors = <"Birger Kollmeier, Antje Wulff", ...> other_details = < ["licence"] = <"This work is licensed under the Creative Commons Attribution-ShareAlike 3.0 License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/3.0/."> ["custodian_organisation"] = <"HiGHmed"> ["references"] = <"Brand, T., & Hohmann, V. (2002). An adaptive procedure for categorical loudness scaling. The Journal of the Acoustical Society of America, 112(4), 1597-1604. Hellbrück, J., & Moser, L. M. (1986). Psychophysical measurements of inner ear processes with category scaling of loudness. ORL, 48(2), 135-136. "> ["original_namespace"] = <"org.highmed"> ["original_publisher"] = <"HiGHmed"> ["custodian_namespace"] = <"org.highmed"> ["MD5-CAM-1.0.1"] = <"D7E24BE74F0C7888FFBAA1D4CBF321E0"> ["build_uid"] = <"ca7a9332-1059-4bed-b361-08f7c413031b"> ["revision"] = <"0.0.1-alpha"> > definition OBSERVATION[at0000] matches { -- Categorical loudness scaling data matches { HISTORY[at0001] matches { -- History events cardinality matches {1..*; unordered} matches { EVENT[at0002] occurrences matches {0..*} matches { -- Any event data matches { ITEM_TREE[at0003] matches { -- Tree items cardinality matches {0..*; unordered} matches { ELEMENT[at0025] occurrences matches {0..1} matches { -- Test result name value matches { DV_TEXT matches {*} } } CLUSTER[at0026] occurrences matches {0..1} matches { -- Result details items cardinality matches {2..*; unordered} matches { ELEMENT[at0027] matches { -- Test ear value matches { DV_CODED_TEXT matches { defining_code matches { [local:: at0028, -- Right ear at0029, -- Left ear at0030] -- Bilateral } } } } CLUSTER[at0031] occurrences matches {0..2} matches { -- Measurement items cardinality matches {1..*; unordered} matches { ELEMENT[at0110] occurrences matches {0..1} matches { -- Level value matches { C_DV_QUANTITY < list = < ["1"] = < units = <"dB"> magnitude = <|-10.0..120.0|> precision = <|0|> > > > } } ELEMENT[at0036] occurrences matches {0..1} matches { -- Frequency value matches { C_DV_QUANTITY < property = <[openehr::382]> list = < ["1"] = < units = <"Hz"> magnitude = <|125.0..16000.0|> precision = <|0|> > ["2"] = < units = <"kHz"> magnitude = <|0.125..16.0|> precision = <|3|> > > > } } ELEMENT[at0040] occurrences matches {0..1} matches { -- Modality value matches { DV_CODED_TEXT matches { defining_code matches { [local:: at0041, -- Narrowband noise at0042, -- Broadband at0043] -- Other (specify) } } } } ELEMENT[at0032] matches { -- Type of measurement mode value matches { DV_CODED_TEXT matches { defining_code matches { [local:: at0033, -- scaling data at0034, -- fitted parameters at0100] -- scaling data + fitted parameters } } } } CLUSTER[at0035] occurrences matches {0..*} matches { -- Response items cardinality matches {2..2; unordered} matches { ELEMENT[at0111] matches { -- Category value matches { C_DV_QUANTITY < list = < ["1"] = < units = <"CU"> magnitude = <|0.0..50.0|> precision = <|0|> > > > } } } } CLUSTER[at0101] occurrences matches {0..1} matches { -- Fitted parameters items cardinality matches {2..2; unordered} matches { ELEMENT[at0103] occurrences matches {0..3} matches { -- slope values value matches { C_DV_QUANTITY < list = < ["1"] = < units = <"CU/dB"> magnitude = <|0.0..10.0|> precision = <|0|> > > > } } ELEMENT[at0112] occurrences matches {0..3} matches { -- Level parameters value matches { C_DV_QUANTITY < list = < ["1"] = < units = <"dB"> magnitude = <|-10.0..120.0|> precision = <|0|> > > > } } ELEMENT[at0104] occurrences matches {0..1} matches { -- Reason for no fitted parameters value matches { DV_CODED_TEXT matches { defining_code matches { [local:: at0105, -- no fit possible at0113] -- other } } } } } } } } } } } } } state matches { ITEM_TREE[at0119] matches { -- Item tree items cardinality matches {0..*; unordered} matches { ELEMENT[at0116] occurrences matches {0..1} matches { -- Aided status value matches { DV_CODED_TEXT matches { defining_code matches { [local:: at0117, -- Aided at0118] -- Unaided } } } } ELEMENT[at0120] occurrences matches {0..1} matches { -- Type of listening device value matches { DV_CODED_TEXT matches { defining_code matches { [local:: at0121, -- Hearing aid at0122, -- Cochlear implant at0123] -- Bone conductor aid } } } } ELEMENT[at0124] occurrences matches {0..1} matches { -- Listening device settings value matches { DV_TEXT matches {*} } } ELEMENT[at0125] occurrences matches {0..1} matches { -- Listening device settings value matches { DV_TEXT matches {*} } } } } } } } } } protocol matches { ITEM_TREE[at0060] matches { -- Item tree items cardinality matches {0..*; unordered} matches { ELEMENT[at0095] occurrences matches {0..1} matches { -- Scaling method value matches { DV_CODED_TEXT matches { defining_code matches { [local:: at0096, -- Adaptive Categorical Loudness Scaling (ACALOS) at0097] -- Würzburger Hörfeldskalierung } } } } allow_archetype CLUSTER[at0061] occurrences matches {0..1} matches { -- Extension include archetype_id/value matches {/.*/} } ELEMENT[at0062] occurrences matches {0..1} matches { -- Presentation value matches { DV_CODED_TEXT matches { defining_code matches { [local:: at0098, -- headphone presentation at0099] -- freefield presentation } } } } ELEMENT[at0069] occurrences matches {0..1} matches { -- Test environment value matches { DV_CODED_TEXT matches { defining_code matches { [local:: at0070, -- Audiometric booth at0071, -- Non-sound treated room at0126] -- free-field } } } } ELEMENT[at0075] occurrences matches {0..1} matches { -- Test stimulus value matches { DV_CODED_TEXT matches { defining_code matches { [local:: at0076, -- Tone burst at0077, -- Click at0078, -- Warble Tone at0079, -- Pure Tone at0080, -- Narrow Band Noise at0081, -- Pulse tone at0127] -- Broadband noise } } } } allow_archetype CLUSTER[at0082] occurrences matches {0..1} matches { -- Test instrument include archetype_id/value matches {/openEHR-EHR-CLUSTER\.device(-[a-zA-Z0-9_]+)*\.v1/} } allow_archetype CLUSTER[at0083] occurrences matches {0..1} matches { -- Hearing device include archetype_id/value matches {/openEHR-EHR-CLUSTER\.device(-[a-zA-Z0-9_]+)*\.v1/} } ELEMENT[at0084] occurrences matches {0..1} matches { -- Reliability value matches { DV_TEXT matches {*} } } ELEMENT[at0085] occurrences matches {0..1} matches { -- Test modifications required value matches { DV_TEXT matches {*} } } ELEMENT[at0086] occurrences matches {0..1} matches { -- Calibration reference dB value matches { DV_CODED_TEXT matches { defining_code matches { [local:: at0087, -- dB SPL at0088, -- dB HL at0089] -- dB nHL } } } } ELEMENT[at0093] occurrences matches {0..1} matches { -- Criteria for abnormality value matches { DV_TEXT matches {*} } null_flavour matches { DV_CODED_TEXT matches { defining_code matches { [openehr:: 253, 271, 273] } } } } ELEMENT[at0094] occurrences matches {0..1} matches { -- Comment value matches { DV_TEXT matches {*} } } } } } } ontology term_definitions = < ["en"] = < items = < ["at0000"] = < text = <"Categorical loudness scaling"> description = <"Categorical loudness scaling"> > ["at0001"] = < text = <"History"> description = <"@ internal @"> > ["at0002"] = < text = <"Any event"> description = <""> > ["at0003"] = < text = <"Tree"> description = <"@ internal @"> > ["at0025"] = < text = <"Test result name"> description = <"Identification of the categorical loudness scaling procedure performed."> comment = <"Coding with an external terminology is preferred, where possible. Applicable tests include: ACALOS, Würzburger Hörfeldskalierung."> > ["at0026"] = < text = <"Result details"> description = <"The test result and interpretations which can be recorded per ear, or for both ears simultaneously."> > ["at0027"] = < text = <"Test ear"> description = <"Identification of the ear(s) to which the test stimulus is being presented."> > ["at0028"] = < text = <"Right ear"> description = <"The test stimuli were presented to the right ear only."> > ["at0029"] = < text = <"Left ear"> description = <"The test stimuli were presented to the left ear only."> > ["at0030"] = < text = <"Bilateral"> description = <"The test stimuli were presented to both ears simultaneously in a soundfield."> > ["at0031"] = < text = <"Measurement"> description = <""> > ["at0032"] = < text = <"Type of measurement mode"> description = <""> > ["at0033"] = < text = <"scaling data"> description = <"each response category for each stimulus level presented"> > ["at0034"] = < text = <"fitted parameters"> description = <"parameters of fitted loudness growth function"> > ["at0035"] = < text = <"Response"> description = <"The reported loudness category for a given stimulus level."> > ["at0036"] = < text = <"Frequency"> description = <"Center frequency of stimulus tested."> comment = <"Frequency is not applicable if a broadband stimulus is used."> > ["at0040"] = < text = <"Modality"> description = <""> > ["at0041"] = < text = <"Narrowband noise"> description = <""> > ["at0042"] = < text = <"Broadband"> description = <""> > ["at0043"] = < text = <"Other (specify)"> description = <""> > ["at0060"] = < text = <"Item tree"> description = <"@ internal @"> > ["at0061"] = < text = <"Extension"> description = <"Additional information required to capture local content or to align with other reference models/formalisms."> comment = <"For example: local information requirements or additional metadata."> > ["at0062"] = < text = <"Presentation"> description = <"Presentation type"> > ["at0069"] = < text = <"Test environment"> description = <"The environment in which the audiometric test is administered."> comment = <"This data element is commonly used in industry hearing programs."> > ["at0070"] = < text = <"Audiometric booth"> description = <"Sound-treated test environment that meets audiometric standards for ambient noise."> > ["at0071"] = < text = <"Non-sound treated room"> description = <"Test environment that does not meet audiometric standards for ambient noise."> > ["at0075"] = < text = <"Test stimulus"> description = <"Identification of the stimulus used in the hearing test to measure the hearing threshold."> > ["at0076"] = < text = <"Tone burst"> description = <"The test stimulus is a tone burst."> > ["at0077"] = < text = <"Click"> description = <"The test stimulus is a click."> > ["at0078"] = < text = <"Warble Tone"> description = <"The test stimulus is a frequency modulated tone."> > ["at0079"] = < text = <"Pure Tone"> description = <"The test stimulus is a pure tone."> > ["at0080"] = < text = <"Narrow Band Noise"> description = <"The test stimulus is a narrow band noise centred on the specified frequency."> > ["at0081"] = < text = <"Pulse tone"> description = <"The test stimulus is a pulse tone."> > ["at0082"] = < text = <"Test instrument"> description = <"Details of device used to conduct the test."> comment = <"Details of the headphones or speakers (freefield presentation) that are calibrated to be used in conjunction with a specific hearing test instrument will be nested as specific CLUSTER archetypes within the CLUSTER.hearing_test_instrument archetype."> > ["at0083"] = < text = <"Hearing device"> description = <"Details of the hearing device used."> comment = <"For example: hearing aid or bone conductor aid."> > ["at0084"] = < text = <"Reliability"> description = <"Narrative description of the reliability of the test results."> comment = <"If an appropriate value set can be determined, this could be coded. The maximum occurrences of this data element have been set to two to allow for both narrative and a coded value to be selected in a template."> > ["at0085"] = < text = <"Test modifications required"> description = <"Narrative description of any modfications to the standard methodology required to enable successful completion of the test."> > ["at0086"] = < text = <"Calibration reference dB"> description = <"Scale used for acoustic calibration of the test signal."> > ["at0087"] = < text = <"dB SPL"> description = <"The test stimuli are calibrated using the sound pressure level scale."> > ["at0088"] = < text = <"dB HL"> description = <"The test stimuli are calibrated using the hearing level scale."> > ["at0089"] = < text = <"dB nHL"> description = <"The test stimuli are calibrated using the normal hearing level scale."> > ["at0093"] = < text = <"Criteria for abnormality"> description = <"The criteria on which deviation from normal in the test result interpretation."> comment = <"For example: lower slope of loudness growth function higher than xx CU/dB"> > ["at0094"] = < text = <"Comment"> description = <"Additional narrative about the protocol for the categorical loudness scaling not captured in other fields."> comment = <"For example, the co-operation of the test subject or description of the method used for testing."> > ["at0095"] = < text = <"Scaling method"> description = <"Choice of scaling method"> > ["at0096"] = < text = <"Adaptive Categorical Loudness Scaling (ACALOS)"> description = <"Method by Brandt & Hohmann 2002"> > ["at0097"] = < text = <"Würzburger Hörfeldskalierung"> description = <"Method by Hellbrück & Moser 1985"> > ["at0098"] = < text = <"headphone presentation"> description = <""> > ["at0099"] = < text = <"freefield presentation"> description = <""> > ["at0100"] = < text = <"scaling data + fitted parameters"> description = <"both"> > ["at0101"] = < text = <"Fitted parameters"> description = <"The reported loudness category for a given stimulus level"> > ["at0103"] = < text = <"slope values"> description = <"Slope values for lower, upper and limiting (if applicable) section of fitted loudness growth function"> > ["at0104"] = < text = <"Reason for no fitted parameters"> description = <""> > ["at0105"] = < text = <"no fit possible"> description = <""> > ["at0110"] = < text = <"Level"> description = <"The level of the stimulus."> > ["at0111"] = < text = <"Category"> description = <"The reported loudness category for a given stimulus level"> > ["at0112"] = < text = <"Level parameters"> description = <"Level values for 5, 25 and 45 CU (if applicable) of fitted loudness growth function."> > ["at0113"] = < text = <"other"> description = <""> > ["at0116"] = < text = <"Aided status"> description = <"Indication regarding use of an assistive listening device by the test subject during the test."> > ["at0117"] = < text = <"Aided"> description = <"The test has been conducted with the patient using a form of auditory assistance, such as a hearing aid or cochlear implant."> > ["at0118"] = < text = <"Unaided"> description = <"The test has been conducted without the patient using any form of auditory assistance, such as a hearing aid or cochlear implant."> > ["at0119"] = < text = <"Item tree"> description = <"@ internal @"> > ["at0120"] = < text = <"Type of listening device"> description = <"Identification of type of assistive listening device used."> comment = <"Only relevant if 'Aid Status' value is 'Aided'."> > ["at0121"] = < text = <"Hearing aid"> description = <"A type of hearing device."> > ["at0122"] = < text = <"Cochlear implant"> description = <"A type of hearing device."> > ["at0123"] = < text = <"Bone conductor aid"> description = <"A type of hearing device."> > ["at0124"] = < text = <"Listening device settings"> description = <"Narrative description of the details of the assistive listening device settings."> > ["at0125"] = < text = <"Listening device settings"> description = <"Narrative description of the details of the assistive listening device settings."> > ["at0126"] = < text = <"free-field"> description = <"Room with free-field characteristics"> > ["at0127"] = < text = <"Broadband noise"> description = <"The test stimulus is a broad band noise"> > > > >