<?xml version="1.0" encoding="UTF-8"?>
<archetype xmlns="http://schemas.openehr.org/v1" xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
  <original_language>
    <terminology_id>
      <value>ISO_639-1</value>
    </terminology_id>
    <code_string>en</code_string>
  </original_language>
  <is_controlled>false</is_controlled>
  <description>
    <original_author id="date">2006-03-26</original_author>
    <original_author id="name">Sam Heard</original_author>
    <original_author id="organisation">Ocean Informatics</original_author>
    <original_author id="email">sam.heard@oceaninformatics.com</original_author>
    <other_contributors>Morten Aas, Diakonhjemmet Sykehus, Norway</other_contributors>
    <other_contributors>Tomas Alme, Norway</other_contributors>
    <other_contributors>Magnus Alvestad, Helse Bergen HF, Norway</other_contributors>
    <other_contributors>Nadim Anani, Karolinska Institutet, Sweden</other_contributors>
    <other_contributors>Anne Pauline Anderssen, Helse Nord RHF, Norway</other_contributors>
    <other_contributors>Vebjørn Arntzen, Oslo universitetssykehus HF, Norway (Nasjonal IKT redaktør)</other_contributors>
    <other_contributors>Koray Atalag, University of Auckland, New Zealand</other_contributors>
    <other_contributors>Gustavo Bacelar-Silva, Healthcare Designs, Brazil (openEHR Editor)</other_contributors>
    <other_contributors>Silje Ljosland Bakke, Nasjonal IKT HF, Norway (Nasjonal IKT redaktør)</other_contributors>
    <other_contributors>Lars Bitsch-Larsen, Haukeland University Hospital, Bergen, Norway</other_contributors>
    <other_contributors>Diego Bosca, IBIME group, Spain</other_contributors>
    <other_contributors>Pål Brekke, OUS Rikshospitalet, Norway</other_contributors>
    <other_contributors>Einar Bugge, UNN HF, Fag- og forskningssenteret, Norway</other_contributors>
    <other_contributors>Rong Chen, Cambio Healthcare Systems, Sweden</other_contributors>
    <other_contributors>Stephen Chu, Queensland Health, Australia</other_contributors>
    <other_contributors>Lisbeth Dahlhaug, Helse Midt - Norge IT, Norway</other_contributors>
    <other_contributors>Angela de Zwart, Orion Health, New Zealand</other_contributors>
    <other_contributors>Graham Denyer, Australian Antarctic Division, Australia</other_contributors>
    <other_contributors>Paul Donaldson, Nursing Informatics Australia, Australia</other_contributors>
    <other_contributors>Shahla Foozonkhah, Ocean Informatics, Australia</other_contributors>
    <other_contributors>Einar Fosse, UNN HF, Norwegian Centre for Integrated Care and Telemedicine, Norway</other_contributors>
    <other_contributors>Sebastian Garde, Ocean Informatics, Germany</other_contributors>
    <other_contributors>John George, HSCIC, United Kingdom</other_contributors>
    <other_contributors>Soon Ghee Yap, Singapore General Hospital, Singapore</other_contributors>
    <other_contributors>Heather Grain, Llewelyn Grain Informatics, Australia</other_contributors>
    <other_contributors>Mikkel Gaup Grønmo, FSE, Helse Nord, Norway (Nasjonal IKT redaktør)</other_contributors>
    <other_contributors>Bjørn Grøva, Diretoratet for e-helse, Norway</other_contributors>
    <other_contributors>Atle Hansen, Universitetssykehuset Nord-Norge, Norway</other_contributors>
    <other_contributors>Sam Heard, Ocean Informatics, Australia</other_contributors>
    <other_contributors>Kristian Heldal, Telemark Hospital Trust, Norway</other_contributors>
    <other_contributors>Andreas Hering, Helse Bergen HF, Haukeland universitetssjukehus, Norway</other_contributors>
    <other_contributors>Erling Are Hole, Helse Bergen, Norway</other_contributors>
    <other_contributors>Evelyn Hovenga, EJSH Consulting, Australia</other_contributors>
    <other_contributors>Eugene Igras, IRIS Systems, Inc., Canada</other_contributors>
    <other_contributors>Tom Jarl Jakobsen, Helse Bergen, Norway</other_contributors>
    <other_contributors>Lars Karlsen, DIPS ASA, Norway</other_contributors>
    <other_contributors>Athanasios Kleontas, Ergobyte Informatics, Greece</other_contributors>
    <other_contributors>Shinji Kobayashi, Kyoto University, Japan</other_contributors>
    <other_contributors>Robert Legan, NEHTA, Australia</other_contributors>
    <other_contributors>Heather Leslie, Ocean Informatics, Australia (openEHR Editor)</other_contributors>
    <other_contributors>Hallvard Lærum, Direktoratet for e-helse, Norway</other_contributors>
    <other_contributors>Rohan Martin, Ambulance Victoria, Australia</other_contributors>
    <other_contributors>Ian McNicoll, freshEHR Clinical Informatics, United Kingdom (openEHR Editor)</other_contributors>
    <other_contributors>Lars Ivar Mehlum, Nasjonal IKT HF, Norway</other_contributors>
    <other_contributors>Jeroen Meintjens, Medisch Centrum Alkmaar, Netherlands</other_contributors>
    <other_contributors>Monica Merchat, Hospital Cardiac Electrophysiology, MS Health Informatics Student, former ICU nurse, former Anesthesia Technician, United States</other_contributors>
    <other_contributors>Bjoern Naess, DIPS ASA, Norway</other_contributors>
    <other_contributors>Andrej Orel, Marand d.o.o., Slovenia</other_contributors>
    <other_contributors>Arturo Romero, SESCAM, Spain</other_contributors>
    <other_contributors>Jussara Rotzsch, UNB, Brazil</other_contributors>
    <other_contributors>Thomas Schopf, University Hospital of North-Norway, Norway</other_contributors>
    <other_contributors>Nils Thomas Songstad, UNN HF, BUK, Barneavdelingen., Norway</other_contributors>
    <other_contributors>Thor-Einar Stemland, Helse Bergen, FOU Seksjon for e-helse, Norway</other_contributors>
    <other_contributors>Arne Løberg Sæter, DIPS ASA, Norway</other_contributors>
    <other_contributors>Jan Inge Sørheim, Helse Bergen, Haukeland uniersitetssjukehus, Norway</other_contributors>
    <other_contributors>Micaela Thierley, Helse Bergen/Haraldsplass sykehus, Norway</other_contributors>
    <other_contributors>Kevin Thon, SKDE, Norway</other_contributors>
    <other_contributors>John Tore Valand, Haukeland Universitetssjukehus, Norway (Nasjonal IKT redaktør)</other_contributors>
    <lifecycle_state>published</lifecycle_state>
    <other_details id="licence">This work is licensed under the Creative Commons Attribution-ShareAlike 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/4.0/.</other_details>
    <other_details id="custodian_organisation">openEHR Foundation</other_details>
    <other_details id="references">Direct communication with clinicians.</other_details>
    <other_details id="current_contact">Heather Leslie, Ocean Informatics, heather.leslie@oceaninformatics.com</other_details>
    <other_details id="original_namespace">org.openehr</other_details>
    <other_details id="original_publisher">openEHR Foundation</other_details>
    <other_details id="custodian_namespace">org.openehr</other_details>
    <other_details id="MD5-CAM-1.0.1">2A940E09AE1750C1009EE5F77FFC95B3</other_details>
    <other_details id="build_uid">6133c0b3-a7bf-41f1-a422-453bf385cea9</other_details>
    <other_details id="revision">2.0.9</other_details>
    <details>
      <language>
        <terminology_id>
          <value>ISO_639-1</value>
        </terminology_id>
        <code_string>de</code_string>
      </language>
      <purpose>Zur Dokumentation der Frequenz und der zugehörigen Attribute einer Puls- oder Herzfrequenz.</purpose>
      <keywords>Frequenz</keywords>
      <keywords>Herzfrequenz</keywords>
      <keywords>Rhythmus</keywords>
      <keywords>Herzschlag</keywords>
      <keywords>Puls</keywords>
      <keywords>Pulsfrequenz</keywords>
      <keywords>Pulsschlag</keywords>
      <keywords>Blutdruck</keywords>
      <keywords>Vitalparameter</keywords>
      <keywords>Vitalzeichen</keywords>
      <use>Zur allgemeinen Dokumentation der vorhandenen oder nicht vorhandenen Puls- oder Herzfrequenz.&#xD;
&#xD;
In der Praxis werden die Begriffe "Herzfrequenz" und "Pulsfrequenz" oft synonym verwendet, obwohl sie an verschiedenen Körperstellen gemessen werden können. Dieser Archetyp ist für beide Begriffe vorgesehen, wobei das Element "Körperstelle" der Unterscheidung dient.&#xD;
&#xD;
Zur Dokumentation der Puls- oder Herzfrequenz und dessen Eigenschaften, sowie der klinischen Interpretationen der Messergebnisse.&#xD;
&#xD;
Messungen, wie die maximale Pulsfrequenz oder die maximale Herzfrequenz, die über eine gewisse Zeit gemessen werden, können im Feature "Event" mit der Bezeichnung "Maximum" dokumentiert werden. Andere zeitpunkt- oder intervallbezogene Ereignisse können innerhalb des Templates oder zur Laufzeit angegeben werden.&#xD;
&#xD;
Bei der Entwicklung dieses Archetyps gab es einige Unstimmigkeiten zu der Darstellung der Regelmäßigkeit der Puls- oder der Herzfrequenz. Dieser Archetyp stellt die relevanten Datenpunkte separat dar: zunächst wird "Regelmäßig" vs. "Unregelmäßig" festgelegt und dann, wenn die Messung "Unregelmäßig" ist, können weitere Optionen von "Normal unregelmäßig" und "Ungleichmäßig Unregelmäßig" angegeben werden. In der Praxis könnten klinische Systeme den Nutzern eine Kombination der Werte aus den beiden Datenelementen "Regelmäßig" und "Unregelmäßig" anbieten - zum Beispiel "Regelmäßig", "Regelmäßig unregelmäßig" und "Ungleichmäßig unregelmäßig", die aus diesen beiden Datenelementen stammen. Die Daten können entgegen einander aufgezeichnet werden, mit der Annahme, dass bei der Angabe einer unregelmäßigen Herzfrequenz auch der Wert "Unregelmäßig" im Datenelement "Regelmäßigkeit" automatisch ausgewählt wird.&#xD;
&#xD;
In bestimmten Situationen ist es wichtig, sehr spezifisch zu sein, damit eine an einer peripheren Körperstelle gemessene Frequenz, wie beispielsweise der Arteria radialis, von der Herzfrequenz unterschieden werden kann. Um ein Pulsdefizit aufzuzeichnen, zeichnen Sie die Messung der mechanischen Herzfrequenz und einer peripheren Pulsfrequenz separat in diesem Archetyp auf - der Unterschied zwischen diesen Messungen ist das Pulsdefizit. Das tatsächliche Pulsdefizit wird in einem separaten OBSERVATION-Archetyp aufgezeichnet.</use>
      <misuse>Nicht zur Dokumentation einer Herzfrequenz, errechnet aus dem RR-Intervall einer EKG-Messung - der Archetyp OBSERVATION.ecg_result soll für diesen Zweck verwendet werden.&#xD;
&#xD;
Nicht zur Dokumentation von Details einer Kardiovaskulären Untersuchung oder Bewertung verwenden. Andere spezifische CLUSTER-Archetypen werden verwendet, um Merkmale wie den Herzspitzenstoß, Herzspitzengeräusche und allgemeine Herzgeräusche oder auskultatorische Befunde aufzuzeichnen.&#xD;
&#xD;
Insbesondere ist dieser Archetyp nicht dazu gedacht, die Beurteilung einer peripheren Gefäßerkrankung aufzuzeichnen, die eine Dokumentation des Vorhandenseins und der Stärke jeder peripheren Pulsfrequenz erfordert. Ein spezifischer CLUSTER-Archetyp wird verwendet, um die allgemeinen Ergebnisse der Untersuchung von peripheren Pulsfrequenzen zu erfassen.&#xD;
&#xD;
Nicht zur Dokumentation des fetalen Blutdrucks verwenden - der Archetyp OBSERVATION.fetal_heart soll für diesen Zweck verwendet werden.&#xD;
&#xD;
Nicht zur Dokumentation des Pulsdefizits verwenden - für diesen Zweck soll ein spezifischer OBSERVATION-Archetyp verwendet werden.&#xD;
&#xD;
Konzepte, wie die Zielherzfrequenz, sollen im Zusammenhang mit dessen Zielen und Trainingsbewertungen in separaten EVALUATION-Archetypen erfasst werden.</misuse>
      <copyright>© openEHR Foundation</copyright>
    </details>
    <details>
      <language>
        <terminology_id>
          <value>ISO_639-1</value>
        </terminology_id>
        <code_string>ru</code_string>
      </language>
      <purpose>Для записи информации о частоте  и ритме  сердцечных сокращений.</purpose>
      <keywords>ЧСС</keywords>
      <keywords>ритм</keywords>
      <keywords>сердечный ритм</keywords>
      <keywords>частотат сердечных сокращений</keywords>
      <use>Используется для записи измеренных характеристик, связанных с темпом и ритма сердца, в том числе простая констатация наличия сердечного ритма. Эти характеристики не регистрируются путем прямого наблюдения самого сердца, а подразумевают альтернативные источники, включая прямую аускультацию сердца или электрокардиограф, отражающий электрическую активность сердца.&#xD;
Частота и ритм сердечных сокращений  (или специализация этого архетипа - Пульс), как правило, регистрируются в качестве одного из компонентов жизненно важных признаков - включая кровяное давление, дыхание, температуру и оксиметрию. Для каждого из этих понятий существуют специальные архетипы.</use>
      <misuse>Не следует использовать для записи выводов о измеряемых частоте и ритме сердечных сокращений. Такого рода заявления, как, например, пациент находится в состоянии фибрилляция предсердий или тахикардии, должны быть записаны в других специальных архетипах, относящихся к категории ОЦЕНКА.&#xD;
Не следует использовать для записи механической частоты сердечных сокращений, ритма и связанные с ними характеристик - это записывается используя специализацию этого архетипа - OBSERVATION.heart_rate-pulse.&#xD;
Не используется для записи другой информации обширной системы обследования или оценки сердечно-сосудистой системы. Другие специфические архетипы используются для записи таких характеристик, как верхушечный толчок, шумы, результаты аускультаци и т.д.&#xD;
Такие понятия, как максимальная или целевая частота сердечных сокращений, должны записываться в отдельных архетипах, предназначенных специально для осуществления оценки.</misuse>
      <copyright>© openEHR Foundation</copyright>
    </details>
    <details>
      <language>
        <terminology_id>
          <value>ISO_639-1</value>
        </terminology_id>
        <code_string>sv</code_string>
      </language>
      <purpose>Att registrera detaljer om frekvens och tillhörande attribut för puls eller hjärtslag.</purpose>
      <keywords>frekvens</keywords>
      <keywords>hjärtfrekvens</keywords>
      <keywords>hjärtslag</keywords>
      <keywords>rytm</keywords>
      <keywords>puls</keywords>
      <keywords>hjärta</keywords>
      <keywords>vitaltecken</keywords>
      <keywords>livstecken</keywords>
      <keywords>vitalparameter</keywords>
      <keywords>HF</keywords>
      <keywords>HR</keywords>
      <use>Används för att registrera närvaro eller frånvaro av puls eller hjärtslag.&#xD;
&#xD;
I praktiken används termerna "pulsfrekvens" och "hjärtfrekvens" ofta utbytbart, även om de kan mätas vid olika anatomiska lokalisationer. Denna arketyp är avsedd att användas för båda termerna och mätplatsen används för att särskilja dem. För att tillgodose klinikers skiftande preferenser tillåter den här arketypen användning av båda termerna och den anatomiska lokalisationen för mätningen skildrar termerna. &#xD;
&#xD;
Används för att registrera mätningen av pulsfrekvens eller hjärtfrekvens samt relaterade observationer avseende deras mönster och karaktär, samt klinisk tolkning av fynden. &#xD;
&#xD;
Mätningar såsom maximal puls eller hjärtfrekvens i ett tidsintervall kan registreras i en "Maximum"-händelse. Andra enstaka händelser eller intervallhändelser kan specificeras i en template, eller genereras automatiskt av vissa IT-system. &#xD;
&#xD;
Vid utvecklingen av denna arketyp har det funnits viss oenighet kring hur regelbundenheten i pulsen eller hjärtslagen ska representeras. Denna arketyp representerar relevanta datapunkter separat: först genom att fastställa "Regelbunden" kontra "Oregelbunden" och därefter, om "Oregelbunden", ytterligare alternativ som "Regelbundet oregelbunden" och "Oregelbundet oregelbunden". I praktiken skulle kliniska informationssystem kunna erbjuda användare en kombination av värden från "Regelbundenhet" och "Oregelbunden typ" – till exempel "Regelbunden", "Regelbundet oregelbunden" och "Oregelbundet oregelbunden", hämtade från dessa två datafält. Data kan registreras mot båda datafälten, med antagandet att om någon av de oregelbundna typerna väljs, så väljs även automatiskt värdet "Oregelbunden" i datafält "Regelbundenhet". &#xD;
&#xD;
I vissa situationer är det viktigt att vara mycket specifik, så att en frekvens som observerats vid en perifer kroppslokalisation, såsom arteria radialis, kan särskiljas från hjärtats frekvens. För att registrera en pulsdeficit, registrera mätningarna av den mekaniska hjärtfrekvensen och en perifer pulsfrekvens i två instanser av denna arketyp – skillnaden mellan dessa mätningar utgör pulsdeficiten. Den faktiska pulsdeficiten ska registreras i en separat OBSERVATION-arketyp.</use>
      <misuse>Ska inte användas för att registrera hjärtfrekvensen från ett elektrokardiogram (EKG). Använd istället arketypen OBSERVATION.ecg. &#xD;
&#xD;
Ska inte användas för att registrera detaljer från en fullständig kardiovaskulär undersökning eller bedömning. Använd istället specifika CLUSTER-arketyper för att registrera egenskaper såsom apexslag, blåsljud och kärlbiljud, eller auskultationsfynd.&#xD;
&#xD;
Ska inte användas för att registrera perifer puls vid bedömning av kärlsjukdomar. Använd istället en specifik CLUSTER-arketyp för att dokumentera närvaro och styrka hos varje perifer puls.&#xD;
&#xD;
Ska inte användas för att registrera hjärtfrekvensen hos foster. Använd istället arketypen OBSERVATION.fetal_heart. &#xD;
&#xD;
Ska inte användas för att registrera pulsdeficit. Använd istället en särskild OBSERVATION-arketyp. &#xD;
&#xD;
Ska inte användas när en specifik puls är ett behandlingsmål. Använd istället specifika EVALUATION-arketyper som är till för mål och bedömning av träning.</misuse>
      <copyright />
    </details>
    <details>
      <language>
        <terminology_id>
          <value>ISO_639-1</value>
        </terminology_id>
        <code_string>fi</code_string>
      </language>
      <purpose>*To record details about the rate and associated attributes for a pulse or heart beat.(en)</purpose>
      <keywords>*rate(en)</keywords>
      <keywords>*rhythm(en)</keywords>
      <keywords>*beat(en)</keywords>
      <keywords>*pulse(en)</keywords>
      <keywords>*heart(en)</keywords>
      <keywords>*vital(en)</keywords>
      <keywords>*sign(en)</keywords>
      <use>*Use to record the presence or absence of a pulse or heart beat.&#xD;
&#xD;
In practice, the terms 'heart rate' and 'pulse rate' are often used interchangeably, although they may be measured at different body sites. This archetype allows either term to be used when the measurement site is not specified, to suit clinician preferences.&#xD;
&#xD;
Use to record the measurement of the pulse rate, or heart rate, observations about the associated pattern and character, and clinical interpretation of the findings.&#xD;
&#xD;
Measurements such as the maximum pulse or heart rate over an interval of time can be recorded using 'Maximum' event. Others point-in-time or interval events may be specified within a template or at run-time.&#xD;
&#xD;
In development of this archetype, there has been some tension around representation of the regularity of the pulse or heart beat. This archetype represents the relevant data points separately: firstly establishing 'Regular' vs 'Irregular' and then, if 'Irregular', further options of 'Regularly irregular' and 'Irregularly irregular'. In practice, clinical systems could offer users a combination of the values from the 'Regular?' and 'Irregular type' - for example, 'Regular', 'Regularly irregular' and 'Irregularly irregular' drawn from these two data elements. Data could be recorded against both data elements with the assumption that if one of the irregular types are selected, then the 'Irregular' value in the 'Regular?' data element is also automatically selected.&#xD;
&#xD;
In certain situations it is important to be very specific so that a rate observed at a peripheral body site, such as the radial artery, can be differentiated from the rate of the heart. To record a pulse deficit, record the measurements of the mechanical heart rate and a peripheral pulse rate in two instances of this archetype - the difference between these measurments is the pulse deficit. The actual pulse deficit will be recorded in a separate OBSERVATION archetype.(en)</use>
      <misuse>*Not to be used to record the R-R rate in the context of an Electrocardiograph report - use the OBSERVATION.ecg archetypefor this purpose.&#xD;
&#xD;
Not to be used to record other details of the full cardiovascular examination or assessment. Other specific CLUSTER archetypes will be used to record characteristics such as apex beat, murmurs and bruits, or auscultatory findings.&#xD;
&#xD;
In particular, this archetype is not intended to record the assessment of peripheral vascular disease, which requires documentation of the presence and strength of each peripheral pulse.  A specific CLUSTER archetype will be used to record the general findings on examination of peripheral pulses.  &#xD;
&#xD;
Not to be used to record fetal heart rate - use the OBSERVATION.fetal_heart archetype for this purpose.&#xD;
&#xD;
Not to be used to record the pulse deficit - use a specific OBSERVATION archetype for this purpose.&#xD;
&#xD;
Concepts such as Target Heart Rate should be recorded in separate EVALUATION archetypes related to goals and exercise assessment.(en)</misuse>
      <copyright />
    </details>
    <details>
      <language>
        <terminology_id>
          <value>ISO_639-1</value>
        </terminology_id>
        <code_string>pt-br</code_string>
      </language>
      <purpose>Para gravar detalhes sobre a frequência e os atributos associados ao pulso ou batimento cardíaco.</purpose>
      <keywords>frequência</keywords>
      <keywords>ritmo</keywords>
      <keywords>batimento</keywords>
      <keywords>pulso</keywords>
      <keywords>coração</keywords>
      <keywords>vital</keywords>
      <keywords>sinal</keywords>
      <use>Use para registrar a presença ou ausência de pulso ou batimento cardíaco.&#xD;
&#xD;
Na prática, os termos "frequência cardíaca" e "frequência do pulso" são frequentemente utilizados indistintamente, embora possam ser medidos em diferentes locais do corpo. Este arquétipo permite que qualquer termo seja usado quando o local da medição não é especificado, de acordo com as preferências clínicas.&#xD;
&#xD;
Use para registrar a medida da freqüência do pulso, ou freqüência cardíaca, observações sobre o padrão e caráter associados e interpretação clínica dos achados.&#xD;
&#xD;
Medições como o pulso máximo ou freqüência cardíaca durante um intervalo de tempo podem ser gravadas usando o evento "Máximo". Outros eventos pontuais ou intervalados podem ser especificados dentro de um modelo ou em tempo de execução.&#xD;
&#xD;
No desenvolvimento deste arquétipo, houve alguma tensão em torno da representação da regularidade do pulso ou batimento cardíaco. Este arquétipo representa os pontos de dados relevantes separadamente: primeiro estabelecendo 'Regular' vs 'Irregular' e, em seguida, 'Irregular', outras opções de 'Regularmente irregular' e 'Irregularmente irregular'. Na prática, os sistemas clínicos poderiam oferecer aos usuários uma combinação dos valores do "Regular?" E 'Tipo irregular' - por exemplo, 'Regular', 'Regularmente irregular' e 'Irregularmente irregular' extraídos destes dois elementos de dados. Os dados poderiam ser registrados contra os dois elementos de dados com a suposição de que, se um dos tipos irregulares for selecionado, então o valor 'Irregular' no elemento de dados 'Regular?' também é automaticamente selecionado.&#xD;
&#xD;
Use para registrar a presença ou ausência de pulso ou batimento cardíaco.&#xD;
&#xD;
Na prática, os termos "frequência cardíaca" e "frequência de pulso" são frequentemente utilizados indistintamente, embora possam ser medidos em diferentes locais do corpo. Este arquétipo permite que qualquer termo seja usado quando o local da medição não é especificado, de acordo com as preferências clínicas.&#xD;
&#xD;
Use para registrar a medida da freqüência do pulso, ou freqüência cardíaca, observações sobre o padrão e caráter associados e interpretação clínica dos achados.&#xD;
&#xD;
Medições como o pulso máximo ou freqüência cardíaca durante um intervalo de tempo podem ser gravadas usando o evento "Máximo". Outros eventos pontuais ou intervalados podem ser especificados dentro de um modelo ou em tempo de execução.&#xD;
&#xD;
No desenvolvimento deste arquétipo, houve alguma tensão em torno da representação da regularidade do pulso ou batimento cardíaco. Este arquétipo representa os pontos de dados relevantes separadamente: primeiro estabelecendo 'Regular' vs 'Irregular' e, em seguida, 'Irregular', outras opções de 'Regularmente irregular' e 'Irregularmente irregular'. Na prática, os sistemas clínicos poderiam oferecer aos usuários uma combinação dos valores do "Regular?" E 'Tipo irregular' - por exemplo, 'Regular', 'Regularmente irregular' e 'Irregularmente irregular' extraídos destes dois elementos de dados. Os dados poderiam ser registrados contra os dois elementos de dados com a suposição de que, se um dos tipos irregulares for selecionado, então o valor 'Irregular' no elemento de dados 'Regular?' também é automaticamente selecionado.&#xD;
&#xD;
Em certas situações, é importante ser muito específico para que uma frequência observada num local do corpo periférico, tal como a artéria radial, possa ser diferenciada da frequência do coração. Para registrar um déficit de pulso, registre as medidas da freqüência cardíaca mecânica e uma frequência de pulso periférico em duas instâncias deste arquétipo - a diferença entre essas medições é o déficit de pulso. O déficit de pulso real será registrado em um arquétipo OBSERVATION separado.</use>
      <misuse>Não deve ser utilizado para registrar a taxa R-R no contexto de um relatório de eletrocardiografia - use o arquétipo OBSERVATION.ecg para este fim.&#xD;
&#xD;
Não deve ser utilizado para registrar outros detalhes do exame ou avaliação cardiovascular completa. Outros arquétipos CLUSTER específicos serão usados para registrar características como a batida do ápice, murmúrios e sopros, ou achados na ausculta.&#xD;
&#xD;
Em particular, este arquétipo não pretende registar a avaliação da doença vascular periférica, que requer documentação da presença e da força de cada pulso periférico. Um arquétipo CLUSTER específico será usado para registrar os achados gerais no exame de pulsos periféricos.&#xD;
&#xD;
Não deve ser usado para registrar a freqüência cardíaca fetal - use o arquétipo OBSERVATION.fetal_heart para esta finalidade.&#xD;
&#xD;
Não deve ser usado para registrar o déficit de pulso - use um arquétipo OBSERVATION específico para este fim.&#xD;
&#xD;
Conceitos como a Frequência Cardíaca-alvo devem ser registrados em arquétipos de EVALUATION separados relacionados com as metas e a avaliação do exercício.</misuse>
      <copyright />
    </details>
    <details>
      <language>
        <terminology_id>
          <value>ISO_639-1</value>
        </terminology_id>
        <code_string>el</code_string>
      </language>
      <purpose>*To record details about the rate and associated attributes for a pulse or heart beat.(en)</purpose>
      <keywords>τιμή</keywords>
      <keywords>ρυθμός</keywords>
      <keywords>νικώ</keywords>
      <keywords>σφυγμός</keywords>
      <keywords>καρδιά</keywords>
      <keywords>ζωτικός</keywords>
      <keywords>σύμπτωμα</keywords>
      <use>*Use to record the presence or absence of a pulse or heart beat.&#xD;
&#xD;
In practice, the terms 'heart rate' and 'pulse rate' are often used interchangeably, although they may be measured at different body sites. This archetype is intended to be used for either term and the measurement site element is used to differentiate them.&#xD;
&#xD;
Use to record the measurement of the pulse rate, or heart rate, observations about the associated pattern and character, and clinical interpretation of the findings.&#xD;
&#xD;
Measurements such as the maximum pulse or heart rate over an interval of time can be recorded using 'Maximum' event. Others point-in-time or interval events may be specified within a template or at run-time.&#xD;
&#xD;
In development of this archetype, there has been some tension around representation of the regularity of the pulse or heart beat. This archetype represents the relevant data points separately: firstly establishing 'Regular' vs 'Irregular' and then, if 'Irregular', further options of 'Regularly irregular' and 'Irregularly irregular'. In practice, clinical systems could offer users a combination of the values from the 'Regularity' and 'Irregular type' - for example, 'Regular', 'Regularly irregular' and 'Irregularly irregular' drawn from these two data elements. Data could be recorded against both data elements with the assumption that if one of the irregular types are selected, then the 'Irregular' value in the 'Regularity' data element is also automatically selected.&#xD;
&#xD;
In certain situations it is important to be very specific so that a rate observed at a peripheral body site, such as the radial artery, can be differentiated from the rate of the heart. To record a pulse deficit, record the measurements of the mechanical heart rate and a peripheral pulse rate in two instances of this archetype - the difference between these measurments is the pulse deficit. The actual pulse deficit will be recorded in a separate OBSERVATION archetype.(en)</use>
      <misuse>*Not to be used to record the R-R rate in the context of an Electrocardiograph report - use the OBSERVATION.ecg archetype for this purpose.&#xD;
&#xD;
Not to be used to record other details of the full cardiovascular examination or assessment. Other specific CLUSTER archetypes will be used to record characteristics such as apex beat, murmurs and bruits, or auscultatory findings.&#xD;
&#xD;
In particular, this archetype is not intended to record the assessment of peripheral vascular disease, which requires documentation of the presence and strength of each peripheral pulse. A specific CLUSTER archetype will be used to record the general findings on examination of peripheral pulses. &#xD;
&#xD;
Not to be used to record fetal heart rate - use the OBSERVATION.fetal_heart archetype for this purpose.&#xD;
&#xD;
Not to be used to record the pulse deficit - use a specific OBSERVATION archetype for this purpose.&#xD;
&#xD;
Concepts such as Target Heart Rate should be recorded in separate EVALUATION archetypes related to goals and exercise assessment.(en)</misuse>
      <copyright />
    </details>
    <details>
      <language>
        <terminology_id>
          <value>ISO_639-1</value>
        </terminology_id>
        <code_string>en</code_string>
      </language>
      <purpose>To record details about the rate and associated attributes for a pulse or heart beat.</purpose>
      <keywords>rate</keywords>
      <keywords>rhythm</keywords>
      <keywords>beat</keywords>
      <keywords>pulse</keywords>
      <keywords>heart</keywords>
      <keywords>vital</keywords>
      <keywords>sign</keywords>
      <use>Use to record the presence or absence of a pulse or heart beat.&#xD;
&#xD;
In practice, the terms 'heart rate' and 'pulse rate' are often used interchangeably, although they may be measured at different body sites. This archetype is intended to be used for either term and the measurement site element is used to differentiate them.&#xD;
&#xD;
Use to record the measurement of the pulse rate, or heart rate, observations about the associated pattern and character, and clinical interpretation of the findings.&#xD;
&#xD;
Measurements such as the maximum pulse or heart rate over an interval of time can be recorded using 'Maximum' event. Others point-in-time or interval events may be specified within a template or at run-time.&#xD;
&#xD;
In development of this archetype, there has been some tension around representation of the regularity of the pulse or heart beat. This archetype represents the relevant data points separately: firstly establishing 'Regular' vs 'Irregular' and then, if 'Irregular', further options of 'Regularly irregular' and 'Irregularly irregular'. In practice, clinical systems could offer users a combination of the values from the 'Regularity' and 'Irregular type' - for example, 'Regular', 'Regularly irregular' and 'Irregularly irregular' drawn from these two data elements. Data could be recorded against both data elements with the assumption that if one of the irregular types are selected, then the 'Irregular' value in the 'Regularity' data element is also automatically selected.&#xD;
&#xD;
In certain situations it is important to be very specific so that a rate observed at a peripheral body site, such as the radial artery, can be differentiated from the rate of the heart. To record a pulse deficit, record the measurements of the mechanical heart rate and a peripheral pulse rate in two instances of this archetype - the difference between these measurments is the pulse deficit. The actual pulse deficit will be recorded in a separate OBSERVATION archetype.</use>
      <misuse>Not to be used to record the R-R rate in the context of an Electrocardiograph report - use the OBSERVATION.ecg archetype for this purpose.&#xD;
&#xD;
Not to be used to record other details of the full cardiovascular examination or assessment. Other specific CLUSTER archetypes will be used to record characteristics such as apex beat, murmurs and bruits, or auscultatory findings.&#xD;
&#xD;
In particular, this archetype is not intended to record the assessment of peripheral vascular disease, which requires documentation of the presence and strength of each peripheral pulse. A specific CLUSTER archetype will be used to record the general findings on examination of peripheral pulses. &#xD;
&#xD;
Not to be used to record fetal heart rate - use the OBSERVATION.fetal_heart archetype for this purpose.&#xD;
&#xD;
Not to be used to record the pulse deficit - use a specific OBSERVATION archetype for this purpose.&#xD;
&#xD;
Concepts such as Target Heart Rate should be recorded in separate EVALUATION archetypes related to goals and exercise assessment.</misuse>
      <copyright>© openEHR Foundation</copyright>
    </details>
    <details>
      <language>
        <terminology_id>
          <value>ISO_639-1</value>
        </terminology_id>
        <code_string>ar-sy</code_string>
      </language>
      <purpose>لتسجيل تفاصيل حول معدل و نظم القلب.</purpose>
      <keywords>المعدل</keywords>
      <keywords>معدل القلب</keywords>
      <keywords>النظم</keywords>
      <use>يستخدم لتسجيل الخصائص التي تم قياسها فيما يتعلق بمعدل و نظم القلب, بما في ذلك بيان بسيط حول وجود نبض و معدل ضربات القلب. و لا يتم استخدام هذه القراءات بالملاحظة المباشرة للقلب ذاته, و إنما يتنم استنباطها من مصادر بديلة تتضمن التسمع المباشر للقلب أو تخطيط كهربية القلب بما يعكس النشاط الكهربي للقلب.&#xD;
معدل و نظم القلب ( أو تخصيصهما إلى النبض) عادة ما يتم تسجيلهم على أنهم يمثلون واحدا من العلامات الحياتية – و التي تتكون من ضغط الدم, التنفس, درجة الحرارة, و قياس التأكسج. و يوجد نماذج إضافية مخصصة لكل نوع من هذه المفاهيم.</use>
      <misuse>لا يستخدم لتسجيل استنتاجات حول معدل و نظم القلب الذي تم قياسهما. و ينبغي تسجيل بيانات مثل (المريض يعاني من الرجفان الأذيني) أو (يعاني من تسرع ضربات القلب) في نماذج أخرى مخصصة و متعلقة بتقييم حالة المريض.&#xD;
لا تستخدم لتسجيل معدل القلب الميكانيكي, أو النظم أو الخصائص الأخرى – و يتم تسجيل ذلك باستخدام تخصيص لهذا النموذج يسمى ملاحظة. معدل القلب – النبض.&#xD;
لا يستخدم لتسجيل تفاصيل فحص أو تقييم أكثر شمولا للجهاز القلبي الوريدي. و يمكن أن تستخدم نماذج معينة أخرى لتسجيل خصائص مثل نبض قمة القلب, النفخات, و الموجودات عند التسمع, إلى آخره.&#xD;
المفاهيم الأخرى مثل أقصى معدل للقلب, أو معدل القلب المستهدف ينبغي أن يتم تسجيلها في نماذج أخرى متعلقة بتقييم المجهود.</misuse>
      <copyright>© openEHR Foundation</copyright>
    </details>
    <details>
      <language>
        <terminology_id>
          <value>ISO_639-1</value>
        </terminology_id>
        <code_string>zh-cn</code_string>
      </language>
      <purpose>旨在记录关于脉搏或心跳的速率和种种相关特征属性/特性/属性的详细信息。</purpose>
      <keywords>速率</keywords>
      <keywords>率</keywords>
      <keywords>节律</keywords>
      <keywords>跳动</keywords>
      <keywords>脉搏</keywords>
      <keywords>搏动</keywords>
      <keywords>心脏</keywords>
      <keywords>生命</keywords>
      <keywords>体征</keywords>
      <keywords>生命体征</keywords>
      <use>旨在用于记录脉搏或心跳的存在情况或者说存在与否。&#xD;
&#xD;
在实践当中，术语“心率”和“脉搏[速]率”经常会互换使用，尽管用于测量二者的身体部位可能有所不同。本原始型旨在用于二者当中的任一术语，并且会利用测量部位元素对二者加以区分。&#xD;
&#xD;
旨在用于记录脉搏率或心率的测量结果、关于相关模式和特征/特点的观察结果以及对于结果/所见的临床解释。&#xD;
&#xD;
可以利用最大值事件“Maximum”来记录一段时间内或者说特定时间区间内最大的脉搏[速]率或心率等测量结果。可以在模板当中或运行时指定其他的时间点/时刻型或时间区间型事件。&#xD;
&#xD;
在开发编制本原始型的过程中，关于脉搏或心跳规律性的表示方法，存在着一些对立的意见。目前，本原始型会分别来表示相关的数据点：首先是确定 “规律”（Regular） 还是 “不规律”（Irregular）；然后，如果为 “不规律”，则进一步选择 “规律性不齐”（Regularly irregular） 还是 “不规律性不齐”（Irregularly irregular）。在实践中，临床系统可以为用户提供“规则性”与“不齐类型”取值的组合，如提取自这两个数据元的“规律”、“规律性不齐”和 “不规律性不齐”。可以同时针对两个数据元来记录数据，而前提则是，如果选择了其中的一种不齐类型，则 还会同时选定规律性数据元“Regularity”之中的取值 “不规律”。&#xD;
&#xD;
在某些情况下，重要的是要做到非常地具体或者说具有针对性，以便将末梢部位（如桡动脉）所观察到的心率与心脏部位所观察到的心率区别开来。要记录脉搏短绌（pulse deficit），请采用本原始型的两个实例来分别记录机械心率（mechanical heart rate）和外周脉搏率（peripheral pulse rate）的测量结果 - 这两个测量结果之间的差值就是脉搏短绌。实际脉搏短绌取值的记录则会采用单独的观察型原始型。</use>
      <misuse>并非旨在用于记录心电图报告上下文背景下的 R-R 间期心率/速率 - 对此，请采用观察型心电图原始型 OBSERVATION.ecg。&#xD;
&#xD;
并非旨在用于记录完整心血管检查或评估结果的其他详情。将会采用其他具有针对性的群簇型原始型莱记录种种的特性/特征，如心尖搏动、心跳杂音/异常音或听诊所见/结果。&#xD;
&#xD;
特别是，本原始型并非旨在用于记录外周血管疾病的评估结果（其中需要记录每次外周脉搏的存在情况和强度）。外周脉搏检查一般所见/发现/结果的记录将会采用具有针对性的群簇型原始型。&#xD;
&#xD;
并非旨在用于记录胎儿心率 - 对此，请采用观察型心电图胎儿心脏原始型 OBSERVATION.fetal_heart。&#xD;
&#xD;
并非旨在用于记录脉搏短绌（pulse deficit） - 对此，请采用具有针对性的观察型原始型。&#xD;
&#xD;
对于目标心率（Target Heart Rate）等概念，则应当采用单独的，与目标和运动评估相关的评估型原始型来加以记录。</misuse>
      <copyright />
    </details>
    <details>
      <language>
        <terminology_id>
          <value>ISO_639-1</value>
        </terminology_id>
        <code_string>es</code_string>
      </language>
      <purpose>Para registrar detalles sobre la frecuencia y los atributos asociados a un pulso o latido cardíaco.</purpose>
      <keywords>frecuencia, ritmo, latido, pulso, corazón, signo, signos vitales</keywords>
      <use>Utilizar para registrar la presencia o ausencia de pulso o latidos cardíacos.&#xD;
&#xD;
En la práctica, los términos "frecuencia cardíaca" y "frecuencia del pulso" suelen usarse indistintamente, aunque pueden medirse en diferentes partes del cuerpo. Este arquetipo está diseñado para usarse con ambos términos y el elemento del lugar de medición se utiliza para diferenciarlos.&#xD;
&#xD;
Utilizar para registrar la medición de la frecuencia del pulso o frecuencia cardíaca, las observaciones sobre el patrón y el carácter asociados y la interpretación clínica de los hallazgos.&#xD;
&#xD;
Medidas como el pulso o latidos máximos en un intervalo de tiempo puede ser registrado en un evento de intervalo asociado a la función 'máximo'. Otros eventos puntuales o intervaloes pueden ser especificados dentro de una plantilla o en tiempo de ejecución.&#xD;
&#xD;
Durante el desarrollo de este arquetipo, ha existido cierta controversia en torno a la representación de la regularidad del pulso o latido cardíaco. Este arquetipo representa los puntos de datos relevantes por separado: primero, se establece "Regular" e "Irregular" y, luego, si es "Irregular", se añaden las opciones "Regularmente irregular" e "Irregularmente irregular". En la práctica, los sistemas clínicos podrían ofrecer a los usuarios una combinación de los valores de "Regularidad" e "Irregular"; por ejemplo, "Regular", "Regularmente irregular" e "Irregularmente irregular" extraídos de estos dos elementos de datos. Los datos podrían registrarse para ambos elementos de datos, asumiendo que, si se selecciona uno de los tipos irregulares, el valor "Irregular" en el elemento de datos "Regularidad" también se selecciona automáticamente.&#xD;
&#xD;
En ciertas situaciones, es importante ser muy específico para poder diferenciar la frecuencia observada en una zona periférica del cuerpo, como la arteria radial, de la frecuencia cardíaca. Para registrar un déficit de pulso, registre las mediciones de la frecuencia cardíaca mecánica y la frecuencia del pulso periférico en dos instancias de este arquetipo; la diferencia entre estas mediciones es el déficit de pulso. El déficit de pulso real se registrará en un arquetipo de OBSERVATION aparte.</use>
      <misuse>No debe ser utilizado para el cálculo de intervalos R-R para la frecuencia cardiaca en el contexto de un estudio electrocardiográfico, para eso utilizar el arquetipo OBSERVATION.ecg.&#xD;
 &#xD;
No debe ser utilizado para registrar otros detalles de la examiniación o evaluación cardiovascular. Para registrar características como latido apexiano, solplos, murmullos y hallazgos específicos, pueden utilizarse otros arquetipos CLUSTER específicos.&#xD;
&#xD;
Este arquetipo no fue diseñado para el registro de la evaluación de enfermedad vascular periférica, la cual requiere documentación sobre la presencia e intensidad de cada pulso periférico. Un CLUSTER específico debe utilizarse para registrar hallazgos generales en la examinación de pulsos periféricos.&#xD;
&#xD;
No debe ser utilizado para registrar la frecuencia cardiaca fetal, esto se registra en el arquetipo OBSERVATION.fetal_heart.&#xD;
&#xD;
No debe utilizarse para registrar el déficit de pulso: utilice un arquetipo de OBSERVATION específico para este propósito.&#xD;
&#xD;
Conceptos como la frecuencia cardiaca objetivo deben ser registrados en arquetipos EVALUATION relacionados a objetivos sobre signos vitales y ejercicio.</misuse>
      <copyright />
    </details>
    <details>
      <language>
        <terminology_id>
          <value>ISO_639-1</value>
        </terminology_id>
        <code_string>es-co</code_string>
      </language>
      <purpose>Registrar la medida de la frecuencia de pulso, la frecuencia cardiaca, y la descripción de las características asociadas como uno de los componentes de las observación de signos vitales</purpose>
      <use>*Use to record the presence or absence of a pulse rate or heart rate. &#xD;
&#xD;
Use to record the measurement of the pulse rate, or heart rate, and observation about the associated rhythm.&#xD;
&#xD;
Use to record a simple description of characteristics that are associated with the pulse or heart beat, that might be commonly recorded as part of a vital signs obervation.&#xD;
&#xD;
Measurements such as the maximum pulse or heart rate over an interval of time can be recorded using "Maximum' event. Others point-in-time or interval events may be specified within a template or at run-time.&#xD;
&#xD;
In practice, the terms heart rate and pulse rate are often used interchangeably. This archetype allows either term to be used when the measurement site is not specified, to suit clincian preferences.&#xD;
&#xD;
In certain situations, however, it is important to differentiate between a pulse rate observed at a peripheral artery, such as the radial artery, in contrast to the centrally observed heart rate. This archetype allows the data to be very specific and differentiate between central heart rate and the pulse rate recorded at a specified artery.(en)</use>
      <misuse>*Not to be used to record the R-R rate in the context of an Electrocardiograph report - this is to be recorded using the OBSERVATION.ecg archetype.&#xD;
&#xD;
Not to be used to record other details of the full cardiovascular examination or assessment. Other specific CLUSTER archetypes will be used to record characteristics such as apex beat, murmurs and bruits, auscultatory findings,&#xD;
&#xD;
In particular, this archetype is not intended to record the assessment of peripheral vascular disease, which requires documentation of the presence and strength of each peripheral pulse.  A specific CLUSTER archetype will be used to record the general findings on examiantion of peripheral pulses.  &#xD;
&#xD;
Not to be used to record fetal heart rate - this is recorded using the OBSERVATION.fetal_heart archetype.&#xD;
&#xD;
Concepts such as Target Heart Rate should be recorded in separate EVALUATION archetypes related to goals and exercise assessment.(en)</misuse>
      <copyright>© openEHR Foundation</copyright>
    </details>
    <details>
      <language>
        <terminology_id>
          <value>ISO_639-1</value>
        </terminology_id>
        <code_string>nb</code_string>
      </language>
      <purpose>For å registrere detaljer om frekvens og tilhørende egenskaper for puls eller hjertefrekvens.</purpose>
      <keywords>frekvens</keywords>
      <keywords>rytme</keywords>
      <keywords>slag</keywords>
      <keywords>puls</keywords>
      <keywords>hjerte</keywords>
      <keywords>pulsslag</keywords>
      <keywords>hjerteslag</keywords>
      <keywords>hjertefrekvens</keywords>
      <use>Brukes til å registrere tilstedeværelse eller fravær av puls eller hjerteslag.&#xD;
&#xD;
Brukes til å registrere en måling av pulsfrekvensen eller hjertefrekvensen, med tilhørende observasjoner rundt rytmen.&#xD;
&#xD;
Målinger som makspuls over et tidsintervall kan registreres ved å bruke en intervallhendelse med en "maksimum"-funksjon. Andre tidspunkts- eller intervallhendelser kan spesifiseres i en template eller i applikasjonen.&#xD;
&#xD;
I praksis brukes begrepene hjertefrekvens og pulsfrekvens mye om hverandre. Denne arketypen tillater uspesifikke registreringer når målestedet ikke er oppgitt, for å best mulig kunne tilpasses klinikernes preferanser.&#xD;
&#xD;
I noen situasjoner er det imidlertid viktig å skille mellom en pulsfrekvens målt ved en perifer arterie som f.eks. arteria radialis, og den sentralt målte hjertefrekvensen. Denne arketypen tillater svært spesifikke data, inkludert en strukturert differensiering mellom sentral hjertefrekvens og perifer pulsfrekvens.&#xD;
&#xD;
Under utviklingen av denne arketypen har det vært diskusjon rundt representasjon av regelmessighet av puls og hjerteslag. Denne arketypen representerer de relevante informasjonselementer separat; Først ved å etablere regelmessig kontra uregelmessig, og hvis uregelmessig så kan det videre beskrives hvilken form for uregelmessighet, hhv. 'Regelmessig uregelmessig' og 'Uregelmessig uregelmessig'. I praksis kan kliniske systemer tilby en kombinasjon av verdiene fra 'Regelmessig' og 'Type uregelmessighet' - for eksempel, 'Regelmessig, 'Regelmessig uregelmessig' og 'Uregelmessig uregelmessig' bli utledet fra disse to dataelementene. Data kan lagres i begge dataelementene med antakelsen om at hvis en av verdiene i 'Type uregelmessighet' er registrert, vil verdien for 'Uregelmessig' i dataelementet 'Rytme' automatisk bli valgt.&#xD;
&#xD;
Ved å bruke to separate instanser kan arketypen benyttes til å registrere målingene av hjertefrekvens og pulsfrekvens som ligger til grunn for en registrering av pulsdeficit. Selve registreringen av pulsdeficitt gjøres imidlertid i en egen OBSERVATION-arketype.</use>
      <misuse>Brukes ikke til å registrere R-R-frekvens i sammenheng med en EKG-rapport, til dette brukes "OBSERVATION.ecg"-arketypen.&#xD;
&#xD;
Skal ikke brukes til å registrere andre deler av en full kardiovaskulær undersøkelse eller vurdering. Til dette brukes spesifikke CLUSTER-arketyper for å registrere andre egenskaper som hjertespisstøt, bilyder og auskultatoriske funn.&#xD;
&#xD;
Arketypen er ikke ment til å registrere vurderingen av perifer karsykdom der det er nødvendig å dokumentere tilstedeværelsen og styrken av hver enkelt perifere puls. Til dette brukes en spesifikk CLUSTER-arketype.&#xD;
&#xD;
Skal ikke brukes til å registrere hjertefrekvensen til et foster, dette gjøres ved hjelp av arketypen "OBSERVATION.fetal_heart".&#xD;
&#xD;
Skal ikke brukes til å registrere pulsdeficit - bruk en spesifik OBSERVATION arketype til dette formålet.&#xD;
&#xD;
Hjertefrekvens som et mål for behandling registreres i egne EVALUATION-arketyper relatert til mål og vurdering av trening.</misuse>
      <copyright />
    </details>
    <details>
      <language>
        <terminology_id>
          <value>ISO_639-1</value>
        </terminology_id>
        <code_string>nl</code_string>
      </language>
      <purpose>Voor het vastleggen van de frequentie en andere eigenschappen van de pols of de hartslag.</purpose>
      <keywords>frequentie</keywords>
      <keywords>ritme</keywords>
      <keywords>slag</keywords>
      <keywords>pols</keywords>
      <keywords>hart</keywords>
      <keywords>vitaal</keywords>
      <keywords>teken</keywords>
      <use>Gebruik voor het vastleggen van de aanwezigheid of afwezigheid van een pols of hartslag.&#xD;
&#xD;
In de praktijk worden de termen hart frequentie and polsfrequentie vaak door elkaar gebruikt, hoewel ze op andere locaties op het lichaam gemeten kunnen worden. Dit archetype is bedoeld om gebruikt te worden voor beide termen en het element meetlocatie wordt gebruikt om ze te onderscheiden.&#xD;
&#xD;
Gebruik voor het vastleggen van een meting van de polsfrequentie of de hartfrequentie, observaties over het bijbehorende patroon, karakter en de klinische interpretatie van de bevindingen.&#xD;
&#xD;
Metingen zoals de maximale pols- of hartfrequentie gedurende een interval kunnen worden vastgelegd met behulp van 'maximum' gebeurtenis. Andere momenten of interval gebeurtenissen kunnen gespecificieerd worden in een template of terwijl de applicatie loopt.&#xD;
&#xD;
Tijdens de ontwikkeling van dit archetype is er spanning geweest rond het vastleggen van de regulariteit van de pols- of hartfreqeuntie. Dit archetype legt de relevante data apart vast: ten eerste door het vastleggen van 'regulair' of 'irregulair' en vervolgens, indien 'irregulair', de extra opties 'regelmatig irregulair' en 'onregelmatig irregulair'. In d praktijk kunnen klinische systemen een combinatie tonen aan de gebruiker van de waardes van de 'regulariteit' en 'irregulair type' - bijvoorbeeld, 'regulair', 'regemlatig irregulair' en 'onregelmatig irregulair' gekozen uit deze twee data elementen. Data kan vastgelegd worden in beide elementen onder de aanname dat wanneer een van de irregulaire types gekozen wordt, dat automatisch de waarde 'irregulair' wordt gekozen in het data element 'regulariteit'.&#xD;
&#xD;
In bepaalde situaties is het belangrijk om heel specifiek te zijn zodat de frequentie, geobserveerd aan een perifeer lichaamslocatie, zoals de arteria radialis, onderscheiden kan worden van de hartfrequentie. Om een polsdeficit vast te leggen, dient de meting van de mechanische hartfrequentie en een perifere hartfrequentie in twee aparte versies van dit archetype vastgelegd te worden - het verschil tussen deze metingen is het polsdeficit. Het daadwerkelijke polsdeficit wordt in een apart OBSERVATION archetype vastgelegd.</use>
      <misuse>Niet te gebruiken voor het vastleggen van de R-R frequentie in de context van een electrocardiogram verslag - gebruik voor dat doel het OBSERVATION.ecg archetype.&#xD;
&#xD;
Niet te gebruiken voor het vastleggen van andere details van een volledig cardiovasculair onderzoek of beoordeling. Andere specifieke CLUSTER archetypes worden gebruikt voor het vastleggen van eigenschappen als apexhartslag, geruizen en bevindingen bij auscultatie. &#xD;
&#xD;
In het bijzonder, is dit archetype niet bedoeld voor het vastleggen van een beoordeling van perifere vaculaire ziekte, die verslaglegging vereisen van de aanwezigheid of kracht van elke individuele perifere pols. Een specifiek CLUSTER archetype wordt gebruikt voor het vastleggen van bevindingen bij onderzoek van de perifere hartslag.&#xD;
&#xD;
Niet te gebruiken voor het vastleggen van foetale hartfrequentie - gebruik voor dat doel het OBSERVATION.fetal_heart archetype.&#xD;
&#xD;
Niet te gebruiken voor het vastleggen van het polsdeficit - gebruik voor dat doel een specifiek OBSERVATION archetype.&#xD;
&#xD;
Concepten zoals streef hart frequentie dienen vastgelegd te worden in een apart EVALUATION archetype gerelateerd aan doelen en inspannings beoordeling.</misuse>
      <copyright />
    </details>
    <details>
      <language>
        <terminology_id>
          <value>ISO_639-1</value>
        </terminology_id>
        <code_string>ca</code_string>
      </language>
      <purpose>Per registrar detalls sobre la freqüència i els atributs associats per a un pols o batec cardíac.</purpose>
      <keywords>freqüència</keywords>
      <keywords>ritme</keywords>
      <keywords>batec</keywords>
      <keywords>pols</keywords>
      <keywords>cor</keywords>
      <keywords>vital</keywords>
      <keywords>signe</keywords>
      <use>S'utilitza per registrar la presència o absència d'un pols o batec cardíac.&#xD;
&#xD;
A la pràctica, els termes "freqüència cardíaca" i "freqüència del pols" sovint s'utilitzen indistintament, encara que es poden mesurar en diferents llocs corporals. Aquest arquetip està destinat a ser utilitzat per a qualsevol terme i l'element del lloc de mesura s'utilitza per diferenciar-los.&#xD;
&#xD;
S'utilitza per registrar la mesura de la freqüència de pols, o freqüència cardíaca, observacions sobre el patró i el caràcter associats, i la interpretació clínica dels resultats.&#xD;
&#xD;
Mesures com el pols màxim o la freqüència cardíaca en un interval de temps es poden registrar utilitzant l'esdeveniment 'Màxim'. Altres esdeveniments puntuals o d'interval es poden especificar dins d'una plantilla o en temps d'execució.&#xD;
&#xD;
En el desenvolupament d'aquest arquetip, hi ha hagut certa tensió al voltant de la representació de la regularitat del pols o batec cardíac. Aquest arquetip representa els punts de dades rellevants per separat: en primer lloc, estableix 'Regular' vs 'Irregular' i després, si 'Irregular', altres opcions de 'Regularment irregular' i 'Irregularment irregular'. A la pràctica, els sistemes clínics podrien oferir als usuaris una combinació dels valors de la 'Regularitat' i el 'tipus irregular' - per exemple, 'Regular', 'Regularitat irregular' i 'irregularitat irregular' extrets d'aquests dos elements de dades. Les dades es podrien registrar contra ambdós elements de dades amb la suposició que si se selecciona un dels tipus irregulars, llavors el valor 'irregular' en l'element de dades 'Regularitat' també se selecciona automàticament.&#xD;
&#xD;
En determinades situacions és important ser molt específic perquè una freqüència observada en un lloc del cos perifèric, com l'artèria radial, es pugui diferenciar de la freqüència del cor. Per registrar un dèficit de pols, registrar les mesures de la freqüència cardíaca mecànica i una freqüència de pols perifèrica en dos casos d'aquest arquetip - la diferència entre aquests mesuraments és el dèficit de pols. El dèficit real de pols es registrarà en un arquetip OBSERVATION separat.</use>
      <misuse>No s'ha d'utilitzar per registrar la freqüència R-R en el context d'un informe d'electrocardiograma - utilitzar l'arquetip OBSERVATION.ecg per a aquest propòsit.&#xD;
&#xD;
No s'ha d'utilitzar per registrar altres detalls de l'examen o avaluació cardiovascular completa. Altres arquetips de CLUSTER específics s'utilitzaran per registrar característiques com el ritme de l'àpex, els murmuris i els frecs, o les troballes auscultatives.&#xD;
&#xD;
En particular, aquest arquetip no pretén registrar l'avaluació de la malaltia vascular perifèrica, que requereix documentació de la presència i la força de cada pols perifèric. S'utilitzarà un arquetip de CLUSTER específic per registrar les troballes generals sobre l'examen dels polsos perifèrics. &#xD;
&#xD;
No s'ha d'utilitzar per registrar la freqüència cardíaca fetal - utilitzeu l'arquetip OBSERVATION.fetal_heart per a aquest propòsit.&#xD;
&#xD;
No s'ha d'utilitzar per registrar el dèficit de pols - utilitzar un arquetip OBSERVATION específic per a aquest propòsit.&#xD;
&#xD;
Conceptes com 'freqüència cardíaca objectiu' s'han de registrar en arquetips EVALUATION separats relacionats amb objectius i avaluació d'exercicis.</misuse>
      <copyright />
    </details>
  </description>
  <translations>
    <language>
      <terminology_id>
        <value>ISO_639-1</value>
      </terminology_id>
      <code_string>de</code_string>
    </language>
    <author id="name">Jasmin Buck, Sebastian Garde, Ramona Wellmann</author>
    <author id="organisation">University of Heidelberg, Central Queensland University, Hannover Medical School</author>
  </translations>
  <translations>
    <language>
      <terminology_id>
        <value>ISO_639-1</value>
      </terminology_id>
      <code_string>ru</code_string>
    </language>
    <author id="name">Vyacheslav Mavrin</author>
    <author id="organisation">JSC Comsoft</author>
  </translations>
  <translations>
    <language>
      <terminology_id>
        <value>ISO_639-1</value>
      </terminology_id>
      <code_string>sv</code_string>
    </language>
    <author id="name">Erik Sundvall, Åsa Skagerhult, Kirsi Poikela, Manna Vosta</author>
    <author id="organisation">Region Östergötland, Tieto Sweden AB, Karolinska University Hospital, Västra Götalandsregionen</author>
    <author id="email">asa.skagerhult@vgregion.se, ext.kirsi.poikela@tieto.com, manna.vosta@regionstockholm.se</author>
  </translations>
  <translations>
    <language>
      <terminology_id>
        <value>ISO_639-1</value>
      </terminology_id>
      <code_string>fi</code_string>
    </language>
    <author id="name">Vesa Peltola</author>
    <author id="organisation">Tieto Finland</author>
    <author id="email">vesa.peltola@tieto.com</author>
  </translations>
  <translations>
    <language>
      <terminology_id>
        <value>ISO_639-1</value>
      </terminology_id>
      <code_string>pt-br</code_string>
    </language>
    <author id="name">Osmeire Chamelette Sanzovo</author>
    <author id="organisation">Hospital Sírio Libanês - SP</author>
    <author id="email">osmeire.acsanzovo@hsl.org.br</author>
  </translations>
  <translations>
    <language>
      <terminology_id>
        <value>ISO_639-1</value>
      </terminology_id>
      <code_string>el</code_string>
    </language>
    <author id="name">Erasmia Partafylla</author>
    <author id="organisation">Sigmasoft</author>
    <author id="email">c.partafylla@sigmasoft.gr</author>
  </translations>
  <translations>
    <language>
      <terminology_id>
        <value>ISO_639-1</value>
      </terminology_id>
      <code_string>ar-sy</code_string>
    </language>
    <author id="name">Mona Saleh</author>
  </translations>
  <translations>
    <language>
      <terminology_id>
        <value>ISO_639-1</value>
      </terminology_id>
      <code_string>zh-cn</code_string>
    </language>
    <author id="name">Lin Zhang</author>
    <author id="organisation">Freelancer</author>
    <author id="email">linforest@163.com</author>
  </translations>
  <translations>
    <language>
      <terminology_id>
        <value>ISO_639-1</value>
      </terminology_id>
      <code_string>es</code_string>
    </language>
    <author id="name">Pablo Pazos, Clara Calleja Vega</author>
    <author id="organisation">CaboLabs - Health Informatics, CatSalut - Servei Català de la Salut.</author>
    <author id="email">pablo.pazos@cabolabs.com, ccalleja@catsalut.cat</author>
  </translations>
  <translations>
    <language>
      <terminology_id>
        <value>ISO_639-1</value>
      </terminology_id>
      <code_string>es-co</code_string>
    </language>
    <author id="name">Jose Florez-Arango</author>
    <accreditation>MD MS PhD</accreditation>
  </translations>
  <translations>
    <language>
      <terminology_id>
        <value>ISO_639-1</value>
      </terminology_id>
      <code_string>nb</code_string>
    </language>
    <author id="name">Silje Ljosland Bakke</author>
    <author id="organisation">Helse Bergen HF</author>
    <author id="email">.</author>
    <accreditation>RN</accreditation>
  </translations>
  <translations>
    <language>
      <terminology_id>
        <value>ISO_639-1</value>
      </terminology_id>
      <code_string>nl</code_string>
    </language>
    <author id="name">Joost Holslag</author>
    <author id="organisation">Nedap</author>
    <author id="email">joost.holslag@nedap.com</author>
    <accreditation>MD</accreditation>
  </translations>
  <translations>
    <language>
      <terminology_id>
        <value>ISO_639-1</value>
      </terminology_id>
      <code_string>ca</code_string>
    </language>
    <author id="name">Clara Calleja Vega</author>
    <author id="organisation">CatSalut. Servei Català de la Salut.</author>
    <author id="email">ccalleja@catsalut.cat</author>
  </translations>
  <uid>
    <value>566c355d-9e8f-473d-a80d-90fcd8d61414</value>
  </uid>
  <archetype_id>
    <value>openEHR-EHR-OBSERVATION.pulse.v2</value>
  </archetype_id>
  <adl_version>1.4</adl_version>
  <concept>at0000</concept>
  <definition>
    <rm_type_name>OBSERVATION</rm_type_name>
    <occurrences>
      <lower_included>true</lower_included>
      <upper_included>true</upper_included>
      <lower_unbounded>false</lower_unbounded>
      <upper_unbounded>false</upper_unbounded>
      <lower>1</lower>
      <upper>1</upper>
    </occurrences>
    <node_id>at0000</node_id>
    <attributes xsi:type="C_SINGLE_ATTRIBUTE">
      <rm_attribute_name>data</rm_attribute_name>
      <existence>
        <lower_included>true</lower_included>
        <upper_included>true</upper_included>
        <lower_unbounded>false</lower_unbounded>
        <upper_unbounded>false</upper_unbounded>
        <lower>1</lower>
        <upper>1</upper>
      </existence>
      <children xsi:type="C_COMPLEX_OBJECT">
        <rm_type_name>HISTORY</rm_type_name>
        <occurrences>
          <lower_included>true</lower_included>
          <upper_included>true</upper_included>
          <lower_unbounded>false</lower_unbounded>
          <upper_unbounded>false</upper_unbounded>
          <lower>1</lower>
          <upper>1</upper>
        </occurrences>
        <node_id>at0002</node_id>
        <attributes xsi:type="C_MULTIPLE_ATTRIBUTE">
          <rm_attribute_name>events</rm_attribute_name>
          <existence>
            <lower_included>true</lower_included>
            <upper_included>true</upper_included>
            <lower_unbounded>false</lower_unbounded>
            <upper_unbounded>false</upper_unbounded>
            <lower>0</lower>
            <upper>1</upper>
          </existence>
          <children xsi:type="C_COMPLEX_OBJECT">
            <rm_type_name>EVENT</rm_type_name>
            <occurrences>
              <lower_included>true</lower_included>
              <lower_unbounded>false</lower_unbounded>
              <upper_unbounded>true</upper_unbounded>
              <lower>0</lower>
            </occurrences>
            <node_id>at0003</node_id>
            <attributes xsi:type="C_SINGLE_ATTRIBUTE">
              <rm_attribute_name>data</rm_attribute_name>
              <existence>
                <lower_included>true</lower_included>
                <upper_included>true</upper_included>
                <lower_unbounded>false</lower_unbounded>
                <upper_unbounded>false</upper_unbounded>
                <lower>1</lower>
                <upper>1</upper>
              </existence>
              <children xsi:type="C_COMPLEX_OBJECT">
                <rm_type_name>ITEM_TREE</rm_type_name>
                <occurrences>
                  <lower_included>true</lower_included>
                  <upper_included>true</upper_included>
                  <lower_unbounded>false</lower_unbounded>
                  <upper_unbounded>false</upper_unbounded>
                  <lower>1</lower>
                  <upper>1</upper>
                </occurrences>
                <node_id>at0001</node_id>
                <attributes xsi:type="C_MULTIPLE_ATTRIBUTE">
                  <rm_attribute_name>items</rm_attribute_name>
                  <existence>
                    <lower_included>true</lower_included>
                    <upper_included>true</upper_included>
                    <lower_unbounded>false</lower_unbounded>
                    <upper_unbounded>false</upper_unbounded>
                    <lower>0</lower>
                    <upper>1</upper>
                  </existence>
                  <children xsi:type="C_COMPLEX_OBJECT">
                    <rm_type_name>ELEMENT</rm_type_name>
                    <occurrences>
                      <lower_included>true</lower_included>
                      <upper_included>true</upper_included>
                      <lower_unbounded>false</lower_unbounded>
                      <upper_unbounded>false</upper_unbounded>
                      <lower>0</lower>
                      <upper>1</upper>
                    </occurrences>
                    <node_id>at1005</node_id>
                    <attributes xsi:type="C_SINGLE_ATTRIBUTE">
                      <rm_attribute_name>value</rm_attribute_name>
                      <existence>
                        <lower_included>true</lower_included>
                        <upper_included>true</upper_included>
                        <lower_unbounded>false</lower_unbounded>
                        <upper_unbounded>false</upper_unbounded>
                        <lower>0</lower>
                        <upper>1</upper>
                      </existence>
                      <children xsi:type="C_COMPLEX_OBJECT">
                        <rm_type_name>DV_CODED_TEXT</rm_type_name>
                        <occurrences>
                          <lower_included>true</lower_included>
                          <upper_included>true</upper_included>
                          <lower_unbounded>false</lower_unbounded>
                          <upper_unbounded>false</upper_unbounded>
                          <lower>1</lower>
                          <upper>1</upper>
                        </occurrences>
                        <node_id />
                        <attributes xsi:type="C_SINGLE_ATTRIBUTE">
                          <rm_attribute_name>defining_code</rm_attribute_name>
                          <existence>
                            <lower_included>true</lower_included>
                            <upper_included>true</upper_included>
                            <lower_unbounded>false</lower_unbounded>
                            <upper_unbounded>false</upper_unbounded>
                            <lower>1</lower>
                            <upper>1</upper>
                          </existence>
                          <children xsi:type="C_CODE_PHRASE">
                            <rm_type_name>CODE_PHRASE</rm_type_name>
                            <occurrences>
                              <lower_included>true</lower_included>
                              <upper_included>true</upper_included>
                              <lower_unbounded>false</lower_unbounded>
                              <upper_unbounded>false</upper_unbounded>
                              <lower>1</lower>
                              <upper>1</upper>
                            </occurrences>
                            <node_id />
                            <terminology_id>
                              <value>local</value>
                            </terminology_id>
                            <code_list>at1024</code_list>
                            <code_list>at1025</code_list>
                          </children>
                        </attributes>
                      </children>
                    </attributes>
                  </children>
                  <children xsi:type="C_COMPLEX_OBJECT">
                    <rm_type_name>ELEMENT</rm_type_name>
                    <occurrences>
                      <lower_included>true</lower_included>
                      <upper_included>true</upper_included>
                      <lower_unbounded>false</lower_unbounded>
                      <upper_unbounded>false</upper_unbounded>
                      <lower>0</lower>
                      <upper>1</upper>
                    </occurrences>
                    <node_id>at0004</node_id>
                    <attributes xsi:type="C_SINGLE_ATTRIBUTE">
                      <rm_attribute_name>value</rm_attribute_name>
                      <existence>
                        <lower_included>true</lower_included>
                        <upper_included>true</upper_included>
                        <lower_unbounded>false</lower_unbounded>
                        <upper_unbounded>false</upper_unbounded>
                        <lower>0</lower>
                        <upper>1</upper>
                      </existence>
                      <children xsi:type="C_DV_QUANTITY">
                        <rm_type_name>DV_QUANTITY</rm_type_name>
                        <occurrences>
                          <lower_included>true</lower_included>
                          <upper_included>true</upper_included>
                          <lower_unbounded>false</lower_unbounded>
                          <upper_unbounded>false</upper_unbounded>
                          <lower>1</lower>
                          <upper>1</upper>
                        </occurrences>
                        <node_id />
                        <property>
                          <terminology_id>
                            <value>openehr</value>
                          </terminology_id>
                          <code_string>382</code_string>
                        </property>
                        <list>
                          <magnitude>
                            <lower_included>true</lower_included>
                            <upper_included>false</upper_included>
                            <lower_unbounded>false</lower_unbounded>
                            <upper_unbounded>false</upper_unbounded>
                            <lower>0.0</lower>
                            <upper>1000.0</upper>
                          </magnitude>
                          <precision>
                            <lower_included>true</lower_included>
                            <upper_included>true</upper_included>
                            <lower_unbounded>false</lower_unbounded>
                            <upper_unbounded>false</upper_unbounded>
                            <lower>0</lower>
                            <upper>0</upper>
                          </precision>
                          <units>/min</units>
                        </list>
                      </children>
                    </attributes>
                  </children>
                  <children xsi:type="C_COMPLEX_OBJECT">
                    <rm_type_name>ELEMENT</rm_type_name>
                    <occurrences>
                      <lower_included>true</lower_included>
                      <upper_included>true</upper_included>
                      <lower_unbounded>false</lower_unbounded>
                      <upper_unbounded>false</upper_unbounded>
                      <lower>0</lower>
                      <upper>1</upper>
                    </occurrences>
                    <node_id>at0005</node_id>
                    <attributes xsi:type="C_SINGLE_ATTRIBUTE">
                      <rm_attribute_name>value</rm_attribute_name>
                      <existence>
                        <lower_included>true</lower_included>
                        <upper_included>true</upper_included>
                        <lower_unbounded>false</lower_unbounded>
                        <upper_unbounded>false</upper_unbounded>
                        <lower>0</lower>
                        <upper>1</upper>
                      </existence>
                      <children xsi:type="C_COMPLEX_OBJECT">
                        <rm_type_name>DV_CODED_TEXT</rm_type_name>
                        <occurrences>
                          <lower_included>true</lower_included>
                          <upper_included>true</upper_included>
                          <lower_unbounded>false</lower_unbounded>
                          <upper_unbounded>false</upper_unbounded>
                          <lower>1</lower>
                          <upper>1</upper>
                        </occurrences>
                        <node_id />
                        <attributes xsi:type="C_SINGLE_ATTRIBUTE">
                          <rm_attribute_name>defining_code</rm_attribute_name>
                          <existence>
                            <lower_included>true</lower_included>
                            <upper_included>true</upper_included>
                            <lower_unbounded>false</lower_unbounded>
                            <upper_unbounded>false</upper_unbounded>
                            <lower>1</lower>
                            <upper>1</upper>
                          </existence>
                          <children xsi:type="C_CODE_PHRASE">
                            <rm_type_name>CODE_PHRASE</rm_type_name>
                            <occurrences>
                              <lower_included>true</lower_included>
                              <upper_included>true</upper_included>
                              <lower_unbounded>false</lower_unbounded>
                              <upper_unbounded>false</upper_unbounded>
                              <lower>1</lower>
                              <upper>1</upper>
                            </occurrences>
                            <node_id />
                            <terminology_id>
                              <value>local</value>
                            </terminology_id>
                            <code_list>at0006</code_list>
                            <code_list>at1028</code_list>
                          </children>
                        </attributes>
                      </children>
                    </attributes>
                  </children>
                  <children xsi:type="C_COMPLEX_OBJECT">
                    <rm_type_name>ELEMENT</rm_type_name>
                    <occurrences>
                      <lower_included>true</lower_included>
                      <upper_included>true</upper_included>
                      <lower_unbounded>false</lower_unbounded>
                      <upper_unbounded>false</upper_unbounded>
                      <lower>0</lower>
                      <upper>1</upper>
                    </occurrences>
                    <node_id>at1055</node_id>
                    <attributes xsi:type="C_SINGLE_ATTRIBUTE">
                      <rm_attribute_name>value</rm_attribute_name>
                      <existence>
                        <lower_included>true</lower_included>
                        <upper_included>true</upper_included>
                        <lower_unbounded>false</lower_unbounded>
                        <upper_unbounded>false</upper_unbounded>
                        <lower>0</lower>
                        <upper>1</upper>
                      </existence>
                      <children xsi:type="C_COMPLEX_OBJECT">
                        <rm_type_name>DV_CODED_TEXT</rm_type_name>
                        <occurrences>
                          <lower_included>true</lower_included>
                          <upper_included>true</upper_included>
                          <lower_unbounded>false</lower_unbounded>
                          <upper_unbounded>false</upper_unbounded>
                          <lower>1</lower>
                          <upper>1</upper>
                        </occurrences>
                        <node_id />
                        <attributes xsi:type="C_SINGLE_ATTRIBUTE">
                          <rm_attribute_name>defining_code</rm_attribute_name>
                          <existence>
                            <lower_included>true</lower_included>
                            <upper_included>true</upper_included>
                            <lower_unbounded>false</lower_unbounded>
                            <upper_unbounded>false</upper_unbounded>
                            <lower>1</lower>
                            <upper>1</upper>
                          </existence>
                          <children xsi:type="C_CODE_PHRASE">
                            <rm_type_name>CODE_PHRASE</rm_type_name>
                            <occurrences>
                              <lower_included>true</lower_included>
                              <upper_included>true</upper_included>
                              <lower_unbounded>false</lower_unbounded>
                              <upper_unbounded>false</upper_unbounded>
                              <lower>1</lower>
                              <upper>1</upper>
                            </occurrences>
                            <node_id />
                            <terminology_id>
                              <value>local</value>
                            </terminology_id>
                            <code_list>at0007</code_list>
                            <code_list>at0008</code_list>
                          </children>
                        </attributes>
                      </children>
                    </attributes>
                  </children>
                  <children xsi:type="C_COMPLEX_OBJECT">
                    <rm_type_name>ELEMENT</rm_type_name>
                    <occurrences>
                      <lower_included>true</lower_included>
                      <lower_unbounded>false</lower_unbounded>
                      <upper_unbounded>true</upper_unbounded>
                      <lower>0</lower>
                    </occurrences>
                    <node_id>at1030</node_id>
                    <attributes xsi:type="C_SINGLE_ATTRIBUTE">
                      <rm_attribute_name>value</rm_attribute_name>
                      <existence>
                        <lower_included>true</lower_included>
                        <upper_included>true</upper_included>
                        <lower_unbounded>false</lower_unbounded>
                        <upper_unbounded>false</upper_unbounded>
                        <lower>0</lower>
                        <upper>1</upper>
                      </existence>
                      <children xsi:type="C_COMPLEX_OBJECT">
                        <rm_type_name>DV_TEXT</rm_type_name>
                        <occurrences>
                          <lower_included>true</lower_included>
                          <upper_included>true</upper_included>
                          <lower_unbounded>false</lower_unbounded>
                          <upper_unbounded>false</upper_unbounded>
                          <lower>1</lower>
                          <upper>1</upper>
                        </occurrences>
                        <node_id />
                      </children>
                    </attributes>
                  </children>
                  <children xsi:type="C_COMPLEX_OBJECT">
                    <rm_type_name>ELEMENT</rm_type_name>
                    <occurrences>
                      <lower_included>true</lower_included>
                      <upper_included>true</upper_included>
                      <lower_unbounded>false</lower_unbounded>
                      <upper_unbounded>false</upper_unbounded>
                      <lower>0</lower>
                      <upper>1</upper>
                    </occurrences>
                    <node_id>at1022</node_id>
                    <attributes xsi:type="C_SINGLE_ATTRIBUTE">
                      <rm_attribute_name>value</rm_attribute_name>
                      <existence>
                        <lower_included>true</lower_included>
                        <upper_included>true</upper_included>
                        <lower_unbounded>false</lower_unbounded>
                        <upper_unbounded>false</upper_unbounded>
                        <lower>0</lower>
                        <upper>1</upper>
                      </existence>
                      <children xsi:type="C_COMPLEX_OBJECT">
                        <rm_type_name>DV_TEXT</rm_type_name>
                        <occurrences>
                          <lower_included>true</lower_included>
                          <upper_included>true</upper_included>
                          <lower_unbounded>false</lower_unbounded>
                          <upper_unbounded>false</upper_unbounded>
                          <lower>1</lower>
                          <upper>1</upper>
                        </occurrences>
                        <node_id />
                      </children>
                    </attributes>
                  </children>
                  <children xsi:type="C_COMPLEX_OBJECT">
                    <rm_type_name>ELEMENT</rm_type_name>
                    <occurrences>
                      <lower_included>true</lower_included>
                      <lower_unbounded>false</lower_unbounded>
                      <upper_unbounded>true</upper_unbounded>
                      <lower>0</lower>
                    </occurrences>
                    <node_id>at1023</node_id>
                    <attributes xsi:type="C_SINGLE_ATTRIBUTE">
                      <rm_attribute_name>name</rm_attribute_name>
                      <existence>
                        <lower_included>true</lower_included>
                        <upper_included>true</upper_included>
                        <lower_unbounded>false</lower_unbounded>
                        <upper_unbounded>false</upper_unbounded>
                        <lower>1</lower>
                        <upper>1</upper>
                      </existence>
                      <children xsi:type="C_COMPLEX_OBJECT">
                        <rm_type_name>DV_CODED_TEXT</rm_type_name>
                        <occurrences>
                          <lower_included>true</lower_included>
                          <upper_included>true</upper_included>
                          <lower_unbounded>false</lower_unbounded>
                          <upper_unbounded>false</upper_unbounded>
                          <lower>1</lower>
                          <upper>1</upper>
                        </occurrences>
                        <node_id />
                        <attributes xsi:type="C_SINGLE_ATTRIBUTE">
                          <rm_attribute_name>defining_code</rm_attribute_name>
                          <existence>
                            <lower_included>true</lower_included>
                            <upper_included>true</upper_included>
                            <lower_unbounded>false</lower_unbounded>
                            <upper_unbounded>false</upper_unbounded>
                            <lower>1</lower>
                            <upper>1</upper>
                          </existence>
                          <children xsi:type="C_CODE_PHRASE">
                            <rm_type_name>CODE_PHRASE</rm_type_name>
                            <occurrences>
                              <lower_included>true</lower_included>
                              <upper_included>true</upper_included>
                              <lower_unbounded>false</lower_unbounded>
                              <upper_unbounded>false</upper_unbounded>
                              <lower>1</lower>
                              <upper>1</upper>
                            </occurrences>
                            <node_id />
                            <terminology_id>
                              <value>local</value>
                            </terminology_id>
                            <code_list>at1057</code_list>
                            <code_list>at1058</code_list>
                          </children>
                        </attributes>
                      </children>
                    </attributes>
                    <attributes xsi:type="C_SINGLE_ATTRIBUTE">
                      <rm_attribute_name>value</rm_attribute_name>
                      <existence>
                        <lower_included>true</lower_included>
                        <upper_included>true</upper_included>
                        <lower_unbounded>false</lower_unbounded>
                        <upper_unbounded>false</upper_unbounded>
                        <lower>0</lower>
                        <upper>1</upper>
                      </existence>
                      <children xsi:type="C_COMPLEX_OBJECT">
                        <rm_type_name>DV_TEXT</rm_type_name>
                        <occurrences>
                          <lower_included>true</lower_included>
                          <upper_included>true</upper_included>
                          <lower_unbounded>false</lower_unbounded>
                          <upper_unbounded>false</upper_unbounded>
                          <lower>1</lower>
                          <upper>1</upper>
                        </occurrences>
                        <node_id />
                      </children>
                    </attributes>
                  </children>
                  <children xsi:type="C_COMPLEX_OBJECT">
                    <rm_type_name>ELEMENT</rm_type_name>
                    <occurrences>
                      <lower_included>true</lower_included>
                      <upper_included>true</upper_included>
                      <lower_unbounded>false</lower_unbounded>
                      <upper_unbounded>false</upper_unbounded>
                      <lower>0</lower>
                      <upper>1</upper>
                    </occurrences>
                    <node_id>at1059</node_id>
                    <attributes xsi:type="C_SINGLE_ATTRIBUTE">
                      <rm_attribute_name>value</rm_attribute_name>
                      <existence>
                        <lower_included>true</lower_included>
                        <upper_included>true</upper_included>
                        <lower_unbounded>false</lower_unbounded>
                        <upper_unbounded>false</upper_unbounded>
                        <lower>0</lower>
                        <upper>1</upper>
                      </existence>
                      <children xsi:type="C_COMPLEX_OBJECT">
                        <rm_type_name>DV_TEXT</rm_type_name>
                        <occurrences>
                          <lower_included>true</lower_included>
                          <upper_included>true</upper_included>
                          <lower_unbounded>false</lower_unbounded>
                          <upper_unbounded>false</upper_unbounded>
                          <lower>1</lower>
                          <upper>1</upper>
                        </occurrences>
                        <node_id />
                      </children>
                    </attributes>
                  </children>
                  <cardinality>
                    <is_ordered>false</is_ordered>
                    <is_unique>false</is_unique>
                    <interval>
                      <lower_included>true</lower_included>
                      <lower_unbounded>false</lower_unbounded>
                      <upper_unbounded>true</upper_unbounded>
                      <lower>0</lower>
                    </interval>
                  </cardinality>
                </attributes>
              </children>
            </attributes>
            <attributes xsi:type="C_SINGLE_ATTRIBUTE">
              <rm_attribute_name>state</rm_attribute_name>
              <existence>
                <lower_included>true</lower_included>
                <upper_included>true</upper_included>
                <lower_unbounded>false</lower_unbounded>
                <upper_unbounded>false</upper_unbounded>
                <lower>0</lower>
                <upper>1</upper>
              </existence>
              <children xsi:type="C_COMPLEX_OBJECT">
                <rm_type_name>ITEM_TREE</rm_type_name>
                <occurrences>
                  <lower_included>true</lower_included>
                  <upper_included>true</upper_included>
                  <lower_unbounded>false</lower_unbounded>
                  <upper_unbounded>false</upper_unbounded>
                  <lower>1</lower>
                  <upper>1</upper>
                </occurrences>
                <node_id>at0012</node_id>
                <attributes xsi:type="C_MULTIPLE_ATTRIBUTE">
                  <rm_attribute_name>items</rm_attribute_name>
                  <existence>
                    <lower_included>true</lower_included>
                    <upper_included>true</upper_included>
                    <lower_unbounded>false</lower_unbounded>
                    <upper_unbounded>false</upper_unbounded>
                    <lower>0</lower>
                    <upper>1</upper>
                  </existence>
                  <children xsi:type="C_COMPLEX_OBJECT">
                    <rm_type_name>ELEMENT</rm_type_name>
                    <occurrences>
                      <lower_included>true</lower_included>
                      <upper_included>true</upper_included>
                      <lower_unbounded>false</lower_unbounded>
                      <upper_unbounded>false</upper_unbounded>
                      <lower>0</lower>
                      <upper>1</upper>
                    </occurrences>
                    <node_id>at0013</node_id>
                    <attributes xsi:type="C_SINGLE_ATTRIBUTE">
                      <rm_attribute_name>value</rm_attribute_name>
                      <existence>
                        <lower_included>true</lower_included>
                        <upper_included>true</upper_included>
                        <lower_unbounded>false</lower_unbounded>
                        <upper_unbounded>false</upper_unbounded>
                        <lower>0</lower>
                        <upper>1</upper>
                      </existence>
                      <children xsi:type="C_COMPLEX_OBJECT">
                        <rm_type_name>DV_CODED_TEXT</rm_type_name>
                        <occurrences>
                          <lower_included>true</lower_included>
                          <upper_included>true</upper_included>
                          <lower_unbounded>false</lower_unbounded>
                          <upper_unbounded>false</upper_unbounded>
                          <lower>1</lower>
                          <upper>1</upper>
                        </occurrences>
                        <node_id />
                        <attributes xsi:type="C_SINGLE_ATTRIBUTE">
                          <rm_attribute_name>defining_code</rm_attribute_name>
                          <existence>
                            <lower_included>true</lower_included>
                            <upper_included>true</upper_included>
                            <lower_unbounded>false</lower_unbounded>
                            <upper_unbounded>false</upper_unbounded>
                            <lower>1</lower>
                            <upper>1</upper>
                          </existence>
                          <children xsi:type="C_CODE_PHRASE">
                            <rm_type_name>CODE_PHRASE</rm_type_name>
                            <occurrences>
                              <lower_included>true</lower_included>
                              <upper_included>true</upper_included>
                              <lower_unbounded>false</lower_unbounded>
                              <upper_unbounded>false</upper_unbounded>
                              <lower>1</lower>
                              <upper>1</upper>
                            </occurrences>
                            <node_id />
                            <terminology_id>
                              <value>local</value>
                            </terminology_id>
                            <code_list>at1003</code_list>
                            <code_list>at1001</code_list>
                            <code_list>at1002</code_list>
                            <code_list>at1000</code_list>
                          </children>
                        </attributes>
                      </children>
                    </attributes>
                  </children>
                  <children xsi:type="C_COMPLEX_OBJECT">
                    <rm_type_name>ELEMENT</rm_type_name>
                    <occurrences>
                      <lower_included>true</lower_included>
                      <lower_unbounded>false</lower_unbounded>
                      <upper_unbounded>true</upper_unbounded>
                      <lower>0</lower>
                    </occurrences>
                    <node_id>at1018</node_id>
                    <attributes xsi:type="C_SINGLE_ATTRIBUTE">
                      <rm_attribute_name>value</rm_attribute_name>
                      <existence>
                        <lower_included>true</lower_included>
                        <upper_included>true</upper_included>
                        <lower_unbounded>false</lower_unbounded>
                        <upper_unbounded>false</upper_unbounded>
                        <lower>0</lower>
                        <upper>1</upper>
                      </existence>
                      <children xsi:type="C_COMPLEX_OBJECT">
                        <rm_type_name>DV_TEXT</rm_type_name>
                        <occurrences>
                          <lower_included>true</lower_included>
                          <upper_included>true</upper_included>
                          <lower_unbounded>false</lower_unbounded>
                          <upper_unbounded>false</upper_unbounded>
                          <lower>1</lower>
                          <upper>1</upper>
                        </occurrences>
                        <node_id />
                      </children>
                    </attributes>
                  </children>
                  <children xsi:type="ARCHETYPE_SLOT">
                    <rm_type_name>CLUSTER</rm_type_name>
                    <occurrences>
                      <lower_included>true</lower_included>
                      <lower_unbounded>false</lower_unbounded>
                      <upper_unbounded>true</upper_unbounded>
                      <lower>0</lower>
                    </occurrences>
                    <node_id>at1017</node_id>
                    <includes>
                      <string_expression>archetype_id/value matches {/openEHR-EHR-CLUSTER\.level_of_exertion(-[a-zA-Z0-9_]+)*\.v1|openEHR-EHR-CLUSTER\.level_of_exertion(-[a-zA-Z0-9_]+)*\.v0/}</string_expression>
                      <expression xsi:type="EXPR_BINARY_OPERATOR">
                        <type>Boolean</type>
                        <operator>2007</operator>
                        <precedence_overridden>false</precedence_overridden>
                        <left_operand xsi:type="EXPR_LEAF">
                          <type>String</type>
                          <item xsi:type="xsd:string">archetype_id/value</item>
                          <reference_type>attribute</reference_type>
                        </left_operand>
                        <right_operand xsi:type="EXPR_LEAF">
                          <type>C_STRING</type>
                          <item xsi:type="C_STRING">
                            <pattern>openEHR-EHR-CLUSTER\.level_of_exertion(-[a-zA-Z0-9_]+)*\.v1|openEHR-EHR-CLUSTER\.level_of_exertion(-[a-zA-Z0-9_]+)*\.v0</pattern>
                          </item>
                          <reference_type>constraint</reference_type>
                        </right_operand>
                      </expression>
                    </includes>
                  </children>
                  <cardinality>
                    <is_ordered>false</is_ordered>
                    <is_unique>false</is_unique>
                    <interval>
                      <lower_included>true</lower_included>
                      <lower_unbounded>false</lower_unbounded>
                      <upper_unbounded>true</upper_unbounded>
                      <lower>0</lower>
                    </interval>
                  </cardinality>
                </attributes>
              </children>
            </attributes>
          </children>
          <children xsi:type="C_COMPLEX_OBJECT">
            <rm_type_name>INTERVAL_EVENT</rm_type_name>
            <occurrences>
              <lower_included>true</lower_included>
              <upper_included>true</upper_included>
              <lower_unbounded>false</lower_unbounded>
              <upper_unbounded>false</upper_unbounded>
              <lower>0</lower>
              <upper>1</upper>
            </occurrences>
            <node_id>at1036</node_id>
            <attributes xsi:type="C_SINGLE_ATTRIBUTE">
              <rm_attribute_name>math_function</rm_attribute_name>
              <existence>
                <lower_included>true</lower_included>
                <upper_included>true</upper_included>
                <lower_unbounded>false</lower_unbounded>
                <upper_unbounded>false</upper_unbounded>
                <lower>1</lower>
                <upper>1</upper>
              </existence>
              <children xsi:type="C_COMPLEX_OBJECT">
                <rm_type_name>DV_CODED_TEXT</rm_type_name>
                <occurrences>
                  <lower_included>true</lower_included>
                  <upper_included>true</upper_included>
                  <lower_unbounded>false</lower_unbounded>
                  <upper_unbounded>false</upper_unbounded>
                  <lower>1</lower>
                  <upper>1</upper>
                </occurrences>
                <node_id />
                <attributes xsi:type="C_SINGLE_ATTRIBUTE">
                  <rm_attribute_name>defining_code</rm_attribute_name>
                  <existence>
                    <lower_included>true</lower_included>
                    <upper_included>true</upper_included>
                    <lower_unbounded>false</lower_unbounded>
                    <upper_unbounded>false</upper_unbounded>
                    <lower>1</lower>
                    <upper>1</upper>
                  </existence>
                  <children xsi:type="C_CODE_PHRASE">
                    <rm_type_name>CODE_PHRASE</rm_type_name>
                    <occurrences>
                      <lower_included>true</lower_included>
                      <upper_included>true</upper_included>
                      <lower_unbounded>false</lower_unbounded>
                      <upper_unbounded>false</upper_unbounded>
                      <lower>1</lower>
                      <upper>1</upper>
                    </occurrences>
                    <node_id />
                    <terminology_id>
                      <value>openehr</value>
                    </terminology_id>
                    <code_list>144</code_list>
                  </children>
                </attributes>
              </children>
            </attributes>
            <attributes xsi:type="C_SINGLE_ATTRIBUTE">
              <rm_attribute_name>data</rm_attribute_name>
              <existence>
                <lower_included>true</lower_included>
                <upper_included>true</upper_included>
                <lower_unbounded>false</lower_unbounded>
                <upper_unbounded>false</upper_unbounded>
                <lower>1</lower>
                <upper>1</upper>
              </existence>
              <children xsi:type="ARCHETYPE_INTERNAL_REF">
                <rm_type_name>ITEM_TREE</rm_type_name>
                <occurrences>
                  <lower_included>true</lower_included>
                  <upper_included>true</upper_included>
                  <lower_unbounded>false</lower_unbounded>
                  <upper_unbounded>false</upper_unbounded>
                  <lower>1</lower>
                  <upper>1</upper>
                </occurrences>
                <node_id />
                <target_path>/data[at0002]/events[at0003]/data[at0001]</target_path>
              </children>
            </attributes>
            <attributes xsi:type="C_SINGLE_ATTRIBUTE">
              <rm_attribute_name>state</rm_attribute_name>
              <existence>
                <lower_included>true</lower_included>
                <upper_included>true</upper_included>
                <lower_unbounded>false</lower_unbounded>
                <upper_unbounded>false</upper_unbounded>
                <lower>0</lower>
                <upper>1</upper>
              </existence>
              <children xsi:type="ARCHETYPE_INTERNAL_REF">
                <rm_type_name>ITEM_TREE</rm_type_name>
                <occurrences>
                  <lower_included>true</lower_included>
                  <upper_included>true</upper_included>
                  <lower_unbounded>false</lower_unbounded>
                  <upper_unbounded>false</upper_unbounded>
                  <lower>1</lower>
                  <upper>1</upper>
                </occurrences>
                <node_id />
                <target_path>/data[at0002]/events[at0003]/state[at0012]</target_path>
              </children>
            </attributes>
          </children>
          <cardinality>
            <is_ordered>false</is_ordered>
            <is_unique>false</is_unique>
            <interval>
              <lower_included>true</lower_included>
              <lower_unbounded>false</lower_unbounded>
              <upper_unbounded>true</upper_unbounded>
              <lower>1</lower>
            </interval>
          </cardinality>
        </attributes>
      </children>
    </attributes>
    <attributes xsi:type="C_SINGLE_ATTRIBUTE">
      <rm_attribute_name>protocol</rm_attribute_name>
      <existence>
        <lower_included>true</lower_included>
        <upper_included>true</upper_included>
        <lower_unbounded>false</lower_unbounded>
        <upper_unbounded>false</upper_unbounded>
        <lower>0</lower>
        <upper>1</upper>
      </existence>
      <children xsi:type="C_COMPLEX_OBJECT">
        <rm_type_name>ITEM_TREE</rm_type_name>
        <occurrences>
          <lower_included>true</lower_included>
          <upper_included>true</upper_included>
          <lower_unbounded>false</lower_unbounded>
          <upper_unbounded>false</upper_unbounded>
          <lower>1</lower>
          <upper>1</upper>
        </occurrences>
        <node_id>at0010</node_id>
        <attributes xsi:type="C_MULTIPLE_ATTRIBUTE">
          <rm_attribute_name>items</rm_attribute_name>
          <existence>
            <lower_included>true</lower_included>
            <upper_included>true</upper_included>
            <lower_unbounded>false</lower_unbounded>
            <upper_unbounded>false</upper_unbounded>
            <lower>0</lower>
            <upper>1</upper>
          </existence>
          <children xsi:type="C_COMPLEX_OBJECT">
            <rm_type_name>ELEMENT</rm_type_name>
            <occurrences>
              <lower_included>true</lower_included>
              <upper_included>true</upper_included>
              <lower_unbounded>false</lower_unbounded>
              <upper_unbounded>false</upper_unbounded>
              <lower>0</lower>
              <upper>1</upper>
            </occurrences>
            <node_id>at1019</node_id>
            <attributes xsi:type="C_SINGLE_ATTRIBUTE">
              <rm_attribute_name>value</rm_attribute_name>
              <existence>
                <lower_included>true</lower_included>
                <upper_included>true</upper_included>
                <lower_unbounded>false</lower_unbounded>
                <upper_unbounded>false</upper_unbounded>
                <lower>0</lower>
                <upper>1</upper>
              </existence>
              <children xsi:type="C_COMPLEX_OBJECT">
                <rm_type_name>DV_CODED_TEXT</rm_type_name>
                <occurrences>
                  <lower_included>true</lower_included>
                  <upper_included>true</upper_included>
                  <lower_unbounded>false</lower_unbounded>
                  <upper_unbounded>false</upper_unbounded>
                  <lower>1</lower>
                  <upper>1</upper>
                </occurrences>
                <node_id />
                <attributes xsi:type="C_SINGLE_ATTRIBUTE">
                  <rm_attribute_name>defining_code</rm_attribute_name>
                  <existence>
                    <lower_included>true</lower_included>
                    <upper_included>true</upper_included>
                    <lower_unbounded>false</lower_unbounded>
                    <upper_unbounded>false</upper_unbounded>
                    <lower>1</lower>
                    <upper>1</upper>
                  </existence>
                  <children xsi:type="C_CODE_PHRASE">
                    <rm_type_name>CODE_PHRASE</rm_type_name>
                    <occurrences>
                      <lower_included>true</lower_included>
                      <upper_included>true</upper_included>
                      <lower_unbounded>false</lower_unbounded>
                      <upper_unbounded>false</upper_unbounded>
                      <lower>1</lower>
                      <upper>1</upper>
                    </occurrences>
                    <node_id />
                    <terminology_id>
                      <value>local</value>
                    </terminology_id>
                    <code_list>at1032</code_list>
                    <code_list>at1033</code_list>
                    <code_list>at1034</code_list>
                    <code_list>at1050</code_list>
                  </children>
                </attributes>
              </children>
            </attributes>
          </children>
          <children xsi:type="C_COMPLEX_OBJECT">
            <rm_type_name>ELEMENT</rm_type_name>
            <occurrences>
              <lower_included>true</lower_included>
              <upper_included>true</upper_included>
              <lower_unbounded>false</lower_unbounded>
              <upper_unbounded>false</upper_unbounded>
              <lower>0</lower>
              <upper>1</upper>
            </occurrences>
            <node_id>at1037</node_id>
            <attributes xsi:type="C_SINGLE_ATTRIBUTE">
              <rm_attribute_name>value</rm_attribute_name>
              <existence>
                <lower_included>true</lower_included>
                <upper_included>true</upper_included>
                <lower_unbounded>false</lower_unbounded>
                <upper_unbounded>false</upper_unbounded>
                <lower>0</lower>
                <upper>1</upper>
              </existence>
              <children xsi:type="C_COMPLEX_OBJECT">
                <rm_type_name>DV_CODED_TEXT</rm_type_name>
                <occurrences>
                  <lower_included>true</lower_included>
                  <upper_included>true</upper_included>
                  <lower_unbounded>false</lower_unbounded>
                  <upper_unbounded>false</upper_unbounded>
                  <lower>1</lower>
                  <upper>1</upper>
                </occurrences>
                <node_id />
                <attributes xsi:type="C_SINGLE_ATTRIBUTE">
                  <rm_attribute_name>defining_code</rm_attribute_name>
                  <existence>
                    <lower_included>true</lower_included>
                    <upper_included>true</upper_included>
                    <lower_unbounded>false</lower_unbounded>
                    <upper_unbounded>false</upper_unbounded>
                    <lower>1</lower>
                    <upper>1</upper>
                  </existence>
                  <children xsi:type="C_CODE_PHRASE">
                    <rm_type_name>CODE_PHRASE</rm_type_name>
                    <occurrences>
                      <lower_included>true</lower_included>
                      <upper_included>true</upper_included>
                      <lower_unbounded>false</lower_unbounded>
                      <upper_unbounded>false</upper_unbounded>
                      <lower>1</lower>
                      <upper>1</upper>
                    </occurrences>
                    <node_id />
                    <terminology_id>
                      <value>local</value>
                    </terminology_id>
                    <code_list>at1038</code_list>
                    <code_list>at1039</code_list>
                    <code_list>at1040</code_list>
                    <code_list>at1041</code_list>
                    <code_list>at1042</code_list>
                    <code_list>at1043</code_list>
                    <code_list>at1044</code_list>
                    <code_list>at1049</code_list>
                    <code_list>at1048</code_list>
                    <code_list>at1047</code_list>
                    <code_list>at1054</code_list>
                    <code_list>at1051</code_list>
                  </children>
                </attributes>
              </children>
              <children xsi:type="C_COMPLEX_OBJECT">
                <rm_type_name>DV_TEXT</rm_type_name>
                <occurrences>
                  <lower_included>true</lower_included>
                  <upper_included>true</upper_included>
                  <lower_unbounded>false</lower_unbounded>
                  <upper_unbounded>false</upper_unbounded>
                  <lower>1</lower>
                  <upper>1</upper>
                </occurrences>
                <node_id />
              </children>
            </attributes>
          </children>
          <children xsi:type="ARCHETYPE_SLOT">
            <rm_type_name>CLUSTER</rm_type_name>
            <occurrences>
              <lower_included>true</lower_included>
              <upper_included>true</upper_included>
              <lower_unbounded>false</lower_unbounded>
              <upper_unbounded>false</upper_unbounded>
              <lower>0</lower>
              <upper>1</upper>
            </occurrences>
            <node_id>at1013</node_id>
            <includes>
              <string_expression>archetype_id/value matches {/openEHR-EHR-CLUSTER\.device(-[a-zA-Z0-9_]+)*\.v1/}</string_expression>
              <expression xsi:type="EXPR_BINARY_OPERATOR">
                <type>Boolean</type>
                <operator>2007</operator>
                <precedence_overridden>false</precedence_overridden>
                <left_operand xsi:type="EXPR_LEAF">
                  <type>String</type>
                  <item xsi:type="xsd:string">archetype_id/value</item>
                  <reference_type>attribute</reference_type>
                </left_operand>
                <right_operand xsi:type="EXPR_LEAF">
                  <type>C_STRING</type>
                  <item xsi:type="C_STRING">
                    <pattern>openEHR-EHR-CLUSTER\.device(-[a-zA-Z0-9_]+)*\.v1</pattern>
                  </item>
                  <reference_type>constraint</reference_type>
                </right_operand>
              </expression>
            </includes>
            <excludes>
              <string_expression>archetype_id/value matches {/.*/}</string_expression>
              <expression xsi:type="EXPR_BINARY_OPERATOR">
                <type>Boolean</type>
                <operator>2007</operator>
                <precedence_overridden>false</precedence_overridden>
                <left_operand xsi:type="EXPR_LEAF">
                  <type>String</type>
                  <item xsi:type="xsd:string">archetype_id/value</item>
                  <reference_type>attribute</reference_type>
                </left_operand>
                <right_operand xsi:type="EXPR_LEAF">
                  <type>C_STRING</type>
                  <item xsi:type="C_STRING">
                    <pattern>.*</pattern>
                  </item>
                  <reference_type>constraint</reference_type>
                </right_operand>
              </expression>
            </excludes>
          </children>
          <children xsi:type="ARCHETYPE_SLOT">
            <rm_type_name>CLUSTER</rm_type_name>
            <occurrences>
              <lower_included>true</lower_included>
              <lower_unbounded>false</lower_unbounded>
              <upper_unbounded>true</upper_unbounded>
              <lower>0</lower>
            </occurrences>
            <node_id>at1056</node_id>
            <includes>
              <string_expression>archetype_id/value matches {/.*/}</string_expression>
              <expression xsi:type="EXPR_BINARY_OPERATOR">
                <type>Boolean</type>
                <operator>2007</operator>
                <precedence_overridden>false</precedence_overridden>
                <left_operand xsi:type="EXPR_LEAF">
                  <type>String</type>
                  <item xsi:type="xsd:string">archetype_id/value</item>
                  <reference_type>attribute</reference_type>
                </left_operand>
                <right_operand xsi:type="EXPR_LEAF">
                  <type>C_STRING</type>
                  <item xsi:type="C_STRING">
                    <pattern>.*</pattern>
                  </item>
                  <reference_type>constraint</reference_type>
                </right_operand>
              </expression>
            </includes>
          </children>
          <cardinality>
            <is_ordered>false</is_ordered>
            <is_unique>false</is_unique>
            <interval>
              <lower_included>true</lower_included>
              <lower_unbounded>false</lower_unbounded>
              <upper_unbounded>true</upper_unbounded>
              <lower>0</lower>
            </interval>
          </cardinality>
        </attributes>
      </children>
    </attributes>
  </definition>
  <ontology>
    <term_definitions language="ar-sy">
      <items code="at0000">
        <items id="text">*Pulse/Heart beat(en)</items>
        <items id="description">*The rate and associated attributes for a pulse or heart beat. (en)</items>
      </items>
      <items code="at0001">
        <items id="text">*structure(en)</items>
        <items id="description">*@ internal @(en)</items>
      </items>
      <items code="at0002">
        <items id="text">*history(en)</items>
        <items id="description">*@ internal @(en)</items>
      </items>
      <items code="at0003">
        <items id="text">*Any event(en)</items>
        <items id="description">*Default, unspecified point in time or interval event which may be explicitly defined in a template or at run-time.(en)</items>
      </items>
      <items code="at0004">
        <items id="text">*Rate(en)</items>
        <items id="description">*The rate of the pulse or heart beat, measured in beats per minute. (en)</items>
      </items>
      <items code="at0005">
        <items id="text">*Regular?(en)</items>
        <items id="description">*Is the pulse or heart beat regular?(en)</items>
      </items>
      <items code="at0006">
        <items id="text">*Regular(en)</items>
        <items id="description">*The pattern is regular.(en)</items>
      </items>
      <items code="at0007">
        <items id="text">*Regularly Irregular(en)</items>
        <items id="description">*The pattern is irregular in a regular pattern,. For example, a dropped beat once every 'n' beats.(en)</items>
      </items>
      <items code="at0008">
        <items id="text">*Irregularly Irregular(en)</items>
        <items id="description">*The pattern is irregular in a chaotic and unpredictable manner. For example, atrial fibrillation.(en)</items>
      </items>
      <items code="at0010">
        <items id="text">*List(en)</items>
        <items id="description">*@ internal @(en)</items>
      </items>
      <items code="at0012">
        <items id="text">*List(en)</items>
        <items id="description">*@ internal @(en)</items>
      </items>
      <items code="at0013">
        <items id="text">*Position(en)</items>
        <items id="description">*The body position of the subject during the observation.(en)</items>
      </items>
      <items code="at1000">
        <items id="text">*Lying(en)</items>
        <items id="description">*The subject was lying flat.(en)</items>
      </items>
      <items code="at1001">
        <items id="text">*Sitting(en)</items>
        <items id="description">*The subject was sitting (for example on bed or chair).(en)</items>
      </items>
      <items code="at1002">
        <items id="text">*Reclining(en)</items>
        <items id="description">*The subject was reclining at an approximate angle of 45 degrees, with the legs elevated to the level of the pelvis.(en)</items>
      </items>
      <items code="at1003">
        <items id="text">*Standing/upright(en)</items>
        <items id="description">*The subject was standing, walking or running.(en)</items>
      </items>
      <items code="at1005">
        <items id="text">*Presence(en)</items>
        <items id="description">*Presence of a pulse or heart beat.(en)</items>
        <items id="comment">*It can be implied that the pulse or heart beat is present if Rate &gt;0 /min. (en)</items>
      </items>
      <items code="at1013">
        <items id="text">*Device(en)</items>
        <items id="description">*Details about the device used to measure the pulse rate or heart rate.(en)</items>
      </items>
      <items code="at1017">
        <items id="text">*Exertion(en)</items>
        <items id="description">*Details about physical exertion being undertaken during the examination.(en)</items>
      </items>
      <items code="at1018">
        <items id="text">*Confounding factors(en)</items>
        <items id="description">*Narrative description about any incidental factors that may affect interpretation of the physical findings.(en)</items>
        <items id="comment">*For example, presence of a pacemaker, level of anxiety; pain or fever etc.(en)</items>
      </items>
      <items code="at1019">
        <items id="text">*Method(en)</items>
        <items id="description">*Method used to observe the pulse or heart beat.(en)</items>
        <items id="comment">*For example, auscultation or electronic monitoring. (en)</items>
      </items>
      <items code="at1022">
        <items id="text">*Clinical description(en)</items>
        <items id="description">*Narrative description about the pulse or heart beat.(en)</items>
      </items>
      <items code="at1023">
        <items id="text">*Clinical interpretation(en)</items>
        <items id="description">*Single word, phrase or brief description that represents the clinical meaning and significance of the pulse or heart beat findings, including the rhythm.(en)</items>
        <items id="comment">*Coding with a terminology is preferred, where possible. For example: Bradycardia, Extrasystoles or Sinus rhythm. Multiple statements are allowed. (en)</items>
      </items>
      <items code="at1024">
        <items id="text">*Present(en)</items>
        <items id="description">*A pulse or heart beat can be detected.(en)</items>
      </items>
      <items code="at1025">
        <items id="text">*Not detected(en)</items>
        <items id="description">*A pulse or heart beat cannot be detected.(en)</items>
      </items>
      <items code="at1028">
        <items id="text">*Irregular(en)</items>
        <items id="description">*The pattern is irregular.(en)</items>
      </items>
      <items code="at1030">
        <items id="text">*Character(en)</items>
        <items id="description">*Description of the character of the pulse or heart beat.(en)</items>
        <items id="comment">*Coding with a terminology is desired, where possible. For example: full, thready, bounding, slow rising, or collapsing. Multiple terms may be recorded.(en)</items>
      </items>
      <items code="at1032">
        <items id="text">*Palpation(en)</items>
        <items id="description">*The findings are observed by physical touch of the observer on the subject.(en)</items>
      </items>
      <items code="at1033">
        <items id="text">*Auscultation(en)</items>
        <items id="description">*The findings are observed with the assistance of a device, such as a stethoscope.(en)</items>
      </items>
      <items code="at1034">
        <items id="text">*Automatic, non-invasive(en)</items>
        <items id="description">*The findings are observed non-invasively using a device such as a pulse oximeter or a stethoscope.(en)</items>
      </items>
      <items code="at1036">
        <items id="text">*Maximum(en)</items>
        <items id="description">*Maximum pulse rate or heart rate observed during a period of exertion.(en)</items>
      </items>
      <items code="at1037">
        <items id="text">*Body site(en)</items>
        <items id="description">*Body site where the pulse or heart beat were observed.(en)</items>
      </items>
      <items code="at1038">
        <items id="text">*Radial Artery - Left(en)</items>
        <items id="description">*The left radial artery.(en)</items>
      </items>
      <items code="at1039">
        <items id="text">*Radial Artery - Right(en)</items>
        <items id="description">*The right radial artery.(en)</items>
      </items>
      <items code="at1040">
        <items id="text">*Heart(en)</items>
        <items id="description">*The region of the heart.(en)</items>
      </items>
      <items code="at1041">
        <items id="text">*Carotid Artery - Left(en)</items>
        <items id="description">*The left carotid artery.(en)</items>
      </items>
      <items code="at1042">
        <items id="text">*Carotid Artery - Right(en)</items>
        <items id="description">*The right carotid artery.(en)</items>
      </items>
      <items code="at1043">
        <items id="text">*Femoral Artery - Left(en)</items>
        <items id="description">*The left femoral artery.(en)</items>
      </items>
      <items code="at1044">
        <items id="text">*Femoral Artery - Right(en)</items>
        <items id="description">*The right femoral artery.(en)</items>
      </items>
      <items code="at1047">
        <items id="text">*Finger(en)</items>
        <items id="description">*An unspecified finger.(en)</items>
      </items>
      <items code="at1048">
        <items id="text">*Brachial artery - Left(en)</items>
        <items id="description">*The left brachial artery.(en)</items>
      </items>
      <items code="at1049">
        <items id="text">*Brachial artery - Right(en)</items>
        <items id="description">*The right brachial artery.(en)</items>
      </items>
      <items code="at1050">
        <items id="text">*Automatic, invasive(en)</items>
        <items id="description">*The findings are observed invasively using a device such as an arterial catheter.(en)</items>
      </items>
      <items code="at1051">
        <items id="text">*Ear lobe(en)</items>
        <items id="description">*The lobe of an unspecified ear.(en)</items>
      </items>
      <items code="at1054">
        <items id="text">*Toe(en)</items>
        <items id="description">*An unspecified toe.(en)</items>
      </items>
      <items code="at1055">
        <items id="text">*Irregular type(en)</items>
        <items id="description">*More specific pattern of an irregular pulse or heart beat.(en)</items>
        <items id="comment">*Selection of a value from this value set is only valid if 'Irregular' is selected from the 'Regularity' data element.(en)</items>
      </items>
      <items code="at1056">
        <items id="text">*Extension(en)</items>
        <items id="description">*Additional information required to capture local content or to align with other reference models/formalisms.(en)</items>
        <items id="comment">*For example: local information requirements or additional metadata to align with FHIR or CIMI equivalents.(en)</items>
      </items>
      <items code="at1057">
        <items id="text">*Clinical interpretation(en)</items>
        <items id="description">*Generic label to allow for any or all statements about the pulse or heart beat.(en)</items>
      </items>
      <items code="at1058">
        <items id="text">*Rhythm(en)</items>
        <items id="description">*Specific conclusion about the rhythm of the pulse or heartbeat, drawn from a combination of the heart rate, pattern and other characteristics observed on examination.(en)</items>
      </items>
      <items code="at1059">
        <items id="text">*Comment(en)</items>
        <items id="description">*Additional narrative about the pulse or heart beat findings not captured in other fields.(en)</items>
      </items>
    </term_definitions>
    <term_definitions language="es-co">
      <items code="at0000">
        <items id="text">*Pulse/Heart beat(en)</items>
        <items id="description">*The rate and associated attributes for a pulse or heart beat. (en)</items>
      </items>
      <items code="at0001">
        <items id="text">*structure(en)</items>
        <items id="description">*@ internal @(en)</items>
      </items>
      <items code="at0002">
        <items id="text">*history(en)</items>
        <items id="description">*@ internal @(en)</items>
      </items>
      <items code="at0003">
        <items id="text">*Any event(en)</items>
        <items id="description">*Default, unspecified point in time or interval event which may be explicitly defined in a template or at run-time.(en)</items>
      </items>
      <items code="at0004">
        <items id="text">*Rate(en)</items>
        <items id="description">*The rate of the pulse or heart beat, measured in beats per minute. (en)</items>
      </items>
      <items code="at0005">
        <items id="text">*Regular?(en)</items>
        <items id="description">*Is the pulse or heart beat regular?(en)</items>
      </items>
      <items code="at0006">
        <items id="text">*Regular(en)</items>
        <items id="description">*The pattern is regular.(en)</items>
      </items>
      <items code="at0007">
        <items id="text">*Regularly Irregular(en)</items>
        <items id="description">*The pattern is irregular in a regular pattern,. For example, a dropped beat once every 'n' beats.(en)</items>
      </items>
      <items code="at0008">
        <items id="text">*Irregularly Irregular(en)</items>
        <items id="description">*The pattern is irregular in a chaotic and unpredictable manner. For example, atrial fibrillation.(en)</items>
      </items>
      <items code="at0010">
        <items id="text">*List(en)</items>
        <items id="description">*@ internal @(en)</items>
      </items>
      <items code="at0012">
        <items id="text">*List(en)</items>
        <items id="description">*@ internal @(en)</items>
      </items>
      <items code="at0013">
        <items id="text">*Position(en)</items>
        <items id="description">*The body position of the subject during the observation.(en)</items>
      </items>
      <items code="at1000">
        <items id="text">*Lying(en)</items>
        <items id="description">*The subject was lying flat.(en)</items>
      </items>
      <items code="at1001">
        <items id="text">*Sitting(en)</items>
        <items id="description">*The subject was sitting (for example on bed or chair).(en)</items>
      </items>
      <items code="at1002">
        <items id="text">*Reclining(en)</items>
        <items id="description">*The subject was reclining at an approximate angle of 45 degrees, with the legs elevated to the level of the pelvis.(en)</items>
      </items>
      <items code="at1003">
        <items id="text">*Standing/upright(en)</items>
        <items id="description">*The subject was standing, walking or running.(en)</items>
      </items>
      <items code="at1005">
        <items id="text">*Presence(en)</items>
        <items id="description">*Presence of a pulse or heart beat.(en)</items>
        <items id="comment">*It can be implied that the pulse or heart beat is present if Rate &gt;0 /min. (en)</items>
      </items>
      <items code="at1013">
        <items id="text">*Device(en)</items>
        <items id="description">*Details about the device used to measure the pulse rate or heart rate.(en)</items>
      </items>
      <items code="at1017">
        <items id="text">*Exertion(en)</items>
        <items id="description">*Details about physical exertion being undertaken during the examination.(en)</items>
      </items>
      <items code="at1018">
        <items id="text">*Confounding factors(en)</items>
        <items id="description">*Narrative description about any incidental factors that may affect interpretation of the physical findings.(en)</items>
        <items id="comment">*For example, presence of a pacemaker, level of anxiety; pain or fever etc.(en)</items>
      </items>
      <items code="at1019">
        <items id="text">*Method(en)</items>
        <items id="description">*Method used to observe the pulse or heart beat.(en)</items>
        <items id="comment">*For example, auscultation or electronic monitoring. (en)</items>
      </items>
      <items code="at1022">
        <items id="text">*Clinical description(en)</items>
        <items id="description">*Narrative description about the pulse or heart beat.(en)</items>
      </items>
      <items code="at1023">
        <items id="text">*Clinical interpretation(en)</items>
        <items id="description">*Single word, phrase or brief description that represents the clinical meaning and significance of the pulse or heart beat findings, including the rhythm.(en)</items>
        <items id="comment">*Coding with a terminology is preferred, where possible. For example: Bradycardia, Extrasystoles or Sinus rhythm. Multiple statements are allowed. (en)</items>
      </items>
      <items code="at1024">
        <items id="text">*Present(en)</items>
        <items id="description">*A pulse or heart beat can be detected.(en)</items>
      </items>
      <items code="at1025">
        <items id="text">*Not detected(en)</items>
        <items id="description">*A pulse or heart beat cannot be detected.(en)</items>
      </items>
      <items code="at1028">
        <items id="text">*Irregular(en)</items>
        <items id="description">*The pattern is irregular.(en)</items>
      </items>
      <items code="at1030">
        <items id="text">*Character(en)</items>
        <items id="description">*Description of the character of the pulse or heart beat.(en)</items>
      </items>
      <items code="at1032">
        <items id="text">*Palpation(en)</items>
        <items id="description">*The findings are observed by physical touch of the observer on the subject.(en)</items>
      </items>
      <items code="at1033">
        <items id="text">*Auscultation(en)</items>
        <items id="description">*The findings are observed with the assistance of a device, such as a stethoscope.(en)</items>
      </items>
      <items code="at1034">
        <items id="text">*Automatic, non-invasive(en)</items>
        <items id="description">*The findings are observed non-invasively using a device such as a pulse oximeter or a stethoscope.(en)</items>
      </items>
      <items code="at1036">
        <items id="text">*Maximum(en)</items>
        <items id="description">*Maximum pulse rate or heart rate observed during a period of exertion.(en)</items>
      </items>
      <items code="at1037">
        <items id="text">*Body site(en)</items>
        <items id="description">*Body site where the pulse or heart beat were observed.(en)</items>
      </items>
      <items code="at1038">
        <items id="text">*Radial Artery - Left(en)</items>
        <items id="description">*The left radial artery.(en)</items>
      </items>
      <items code="at1039">
        <items id="text">*Radial Artery - Right(en)</items>
        <items id="description">*The right radial artery.(en)</items>
      </items>
      <items code="at1040">
        <items id="text">*Heart(en)</items>
        <items id="description">*The region of the heart.(en)</items>
      </items>
      <items code="at1041">
        <items id="text">*Carotid Artery - Left(en)</items>
        <items id="description">*The left carotid artery.(en)</items>
      </items>
      <items code="at1042">
        <items id="text">*Carotid Artery - Right(en)</items>
        <items id="description">*The right carotid artery.(en)</items>
      </items>
      <items code="at1043">
        <items id="text">*Femoral Artery - Left(en)</items>
        <items id="description">*The left femoral artery.(en)</items>
      </items>
      <items code="at1044">
        <items id="text">*Femoral Artery - Right(en)</items>
        <items id="description">*The right femoral artery.(en)</items>
      </items>
      <items code="at1047">
        <items id="text">*Finger(en)</items>
        <items id="description">*An unspecified finger.(en)</items>
      </items>
      <items code="at1048">
        <items id="text">*Brachial artery - Left(en)</items>
        <items id="description">*The left brachial artery.(en)</items>
      </items>
      <items code="at1049">
        <items id="text">*Brachial artery - Right(en)</items>
        <items id="description">*The right brachial artery.(en)</items>
      </items>
      <items code="at1050">
        <items id="text">*Automatic, invasive(en)</items>
        <items id="description">*The findings are observed invasively using a device such as an arterial catheter.(en)</items>
      </items>
      <items code="at1051">
        <items id="text">*Ear lobe(en)</items>
        <items id="description">*The lobe of an unspecified ear.(en)</items>
      </items>
      <items code="at1054">
        <items id="text">*Toe(en)</items>
        <items id="description">*An unspecified toe.(en)</items>
      </items>
      <items code="at1055">
        <items id="text">*Irregular type(en)</items>
        <items id="description">*More specific pattern of an irregular pulse or heart beat.(en)</items>
        <items id="comment">*Selection of a value from this value set is only valid if 'Irregular' is selected from the 'Regularity' data element.(en)</items>
      </items>
      <items code="at1056">
        <items id="text">*Extension(en)</items>
        <items id="description">*Additional information required to capture local content or to align with other reference models/formalisms.(en)</items>
        <items id="comment">*For example: local information requirements or additional metadata to align with FHIR or CIMI equivalents.(en)</items>
      </items>
      <items code="at1057">
        <items id="text">*Clinical interpretation(en)</items>
        <items id="description">*Generic label to allow for any or all statements about the pulse or heart beat.(en)</items>
      </items>
      <items code="at1058">
        <items id="text">*Rhythm(en)</items>
        <items id="description">*Specific conclusion about the rhythm of the pulse or heartbeat, drawn from a combination of the heart rate, pattern and other characteristics observed on examination.(en)</items>
      </items>
      <items code="at1059">
        <items id="text">*Comment(en)</items>
        <items id="description">*Additional narrative about the pulse or heart beat findings not captured in other fields.(en)</items>
      </items>
    </term_definitions>
    <term_definitions language="en">
      <items code="at0000">
        <items id="text">Pulse/Heart beat</items>
        <items id="description">The rate and associated attributes for a pulse or heart beat.</items>
      </items>
      <items code="at0001">
        <items id="text">structure</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0002">
        <items id="text">history</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0003">
        <items id="text">Any event</items>
        <items id="description">Default, unspecified point in time or interval event which may be explicitly defined in a template or at run-time.</items>
      </items>
      <items code="at0004">
        <items id="text">Rate</items>
        <items id="description">The rate of the pulse or heart beat, measured in beats per minute.</items>
      </items>
      <items code="at0005">
        <items id="text">Regularity</items>
        <items id="description">Regularity of the pulse or heart beat.</items>
      </items>
      <items code="at0006">
        <items id="text">Regular</items>
        <items id="description">The pattern is regular.</items>
      </items>
      <items code="at0007">
        <items id="text">Regularly Irregular</items>
        <items id="description">The pattern is irregular in a regular pattern,. For example, a dropped beat once every 'n' beats.</items>
      </items>
      <items code="at0008">
        <items id="text">Irregularly Irregular</items>
        <items id="description">The pattern is irregular in a chaotic and unpredictable manner. For example, atrial fibrillation.</items>
      </items>
      <items code="at0010">
        <items id="text">List</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0012">
        <items id="text">List</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0013">
        <items id="text">Position</items>
        <items id="description">The body position of the subject during the observation.</items>
      </items>
      <items code="at1000">
        <items id="text">Lying</items>
        <items id="description">The subject was lying flat.</items>
      </items>
      <items code="at1001">
        <items id="text">Sitting</items>
        <items id="description">The subject was sitting (for example on bed or chair).</items>
      </items>
      <items code="at1002">
        <items id="text">Reclining</items>
        <items id="description">The subject was reclining at an approximate angle of 45 degrees, with the legs elevated to the level of the pelvis.</items>
      </items>
      <items code="at1003">
        <items id="text">Standing/upright</items>
        <items id="description">The subject was standing, walking or running.</items>
      </items>
      <items code="at1005">
        <items id="text">Presence</items>
        <items id="description">Presence of a pulse or heart beat.</items>
        <items id="comment">It can be implied that the pulse or heart beat is present if Rate &gt;0 /min.</items>
      </items>
      <items code="at1013">
        <items id="text">Device</items>
        <items id="description">Details about the device used to measure the pulse rate or heart rate.</items>
      </items>
      <items code="at1017">
        <items id="text">Exertion</items>
        <items id="description">Details about physical exertion being undertaken during the examination.</items>
      </items>
      <items code="at1018">
        <items id="text">Confounding factors</items>
        <items id="description">Narrative description about any incidental factors that may affect interpretation of the physical findings.</items>
        <items id="comment">For example, presence of a pacemaker, level of anxiety; pain or fever etc.</items>
      </items>
      <items code="at1019">
        <items id="text">Method</items>
        <items id="description">Method used to observe the pulse or heart beat.</items>
        <items id="comment">For example, auscultation or electronic monitoring.</items>
      </items>
      <items code="at1022">
        <items id="text">Clinical description</items>
        <items id="description">Narrative description about the pulse or heart beat.</items>
      </items>
      <items code="at1023">
        <items id="text">Clinical interpretation</items>
        <items id="description">Single word, phrase or brief description that represents the clinical meaning and significance of the pulse or heart beat findings, including the rhythm.</items>
        <items id="comment">Coding with a terminology is preferred, where possible. For example: Bradycardia, Extrasystoles or Sinus rhythm. Multiple statements are allowed.</items>
      </items>
      <items code="at1024">
        <items id="text">Present</items>
        <items id="description">A pulse or heart beat can be detected.</items>
      </items>
      <items code="at1025">
        <items id="text">Not detected</items>
        <items id="description">A pulse or heart beat cannot be detected.</items>
      </items>
      <items code="at1028">
        <items id="text">Irregular</items>
        <items id="description">The pattern is irregular.</items>
      </items>
      <items code="at1030">
        <items id="text">Character</items>
        <items id="description">Description of the character of the pulse or heart beat.</items>
        <items id="comment">Coding with a terminology is desired, where possible. For example: full, thready, bounding, slow rising, or collapsing. Multiple terms may be recorded.</items>
      </items>
      <items code="at1032">
        <items id="text">Palpation</items>
        <items id="description">The findings are observed by physical touch of the observer on the subject.</items>
      </items>
      <items code="at1033">
        <items id="text">Auscultation</items>
        <items id="description">The findings are observed with the assistance of a device, such as a stethoscope.</items>
      </items>
      <items code="at1034">
        <items id="text">Automatic, non-invasive</items>
        <items id="description">The findings are observed non-invasively using a device such as a pulse oximeter or a stethoscope.</items>
      </items>
      <items code="at1036">
        <items id="text">Maximum</items>
        <items id="description">Maximum pulse rate or heart rate observed during a period of exertion.</items>
      </items>
      <items code="at1037">
        <items id="text">Body site</items>
        <items id="description">Body site where the pulse or heart beat were observed.</items>
      </items>
      <items code="at1038">
        <items id="text">Radial Artery - Left</items>
        <items id="description">The left radial artery.</items>
      </items>
      <items code="at1039">
        <items id="text">Radial Artery - Right</items>
        <items id="description">The right radial artery.</items>
      </items>
      <items code="at1040">
        <items id="text">Heart</items>
        <items id="description">The region of the heart.</items>
      </items>
      <items code="at1041">
        <items id="text">Carotid Artery - Left</items>
        <items id="description">The left carotid artery.</items>
      </items>
      <items code="at1042">
        <items id="text">Carotid Artery - Right</items>
        <items id="description">The right carotid artery.</items>
      </items>
      <items code="at1043">
        <items id="text">Femoral Artery - Left</items>
        <items id="description">The left femoral artery.</items>
      </items>
      <items code="at1044">
        <items id="text">Femoral Artery - Right</items>
        <items id="description">The right femoral artery.</items>
      </items>
      <items code="at1047">
        <items id="text">Finger</items>
        <items id="description">An unspecified finger.</items>
      </items>
      <items code="at1048">
        <items id="text">Brachial artery - Left</items>
        <items id="description">The left brachial artery.</items>
      </items>
      <items code="at1049">
        <items id="text">Brachial artery - Right</items>
        <items id="description">The right brachial artery.</items>
      </items>
      <items code="at1050">
        <items id="text">Automatic, invasive</items>
        <items id="description">The findings are observed invasively using a device such as an arterial catheter.</items>
      </items>
      <items code="at1051">
        <items id="text">Ear lobe</items>
        <items id="description">The lobe of an unspecified ear.</items>
      </items>
      <items code="at1054">
        <items id="text">Toe</items>
        <items id="description">An unspecified toe.</items>
      </items>
      <items code="at1055">
        <items id="text">Irregular type</items>
        <items id="description">More specific pattern of an irregular pulse or heart beat.</items>
        <items id="comment">Selection of a value from this value set is only valid if 'Irregular' is selected from the 'Regularity' data element.</items>
      </items>
      <items code="at1056">
        <items id="text">Extension</items>
        <items id="description">Additional information required to capture local content or to align with other reference models/formalisms.</items>
        <items id="comment">For example: local information requirements or additional metadata to align with FHIR or CIMI equivalents.</items>
      </items>
      <items code="at1057">
        <items id="text">Clinical interpretation</items>
        <items id="description">Generic label to allow for any or all statements about the pulse or heart beat.</items>
      </items>
      <items code="at1058">
        <items id="text">Rhythm</items>
        <items id="description">Specific conclusion about the rhythm of the pulse or heartbeat, drawn from a combination of the heart rate, pattern and other characteristics observed on examination.</items>
      </items>
      <items code="at1059">
        <items id="text">Comment</items>
        <items id="description">Additional narrative about the pulse or heart beat findings not captured in other fields.</items>
      </items>
    </term_definitions>
    <term_definitions language="de">
      <items code="at0000">
        <items id="text">Pulsfrequenz/Herzfrequenz</items>
        <items id="description">Die Frequenz und zugehörige Attribute für die Puls- oder Herzfrequenz.</items>
      </items>
      <items code="at0001">
        <items id="text">Structure</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0002">
        <items id="text">History</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0003">
        <items id="text">Jedes Ereignis</items>
        <items id="description">Ein Standardwert, ein spezifizierter Zeitpunkt oder ein Intervallereignis, welches explizit in einem Template oder während der Laufzeit definiert werden kann.</items>
      </items>
      <items code="at0004">
        <items id="text">Frequenz</items>
        <items id="description">Die Frequenz, gemessen in Schlägen pro Minute.</items>
      </items>
      <items code="at0005">
        <items id="text">Regelmäßigkeit</items>
        <items id="description">Regelmäßigkeit der Puls-/Herzfrequenz.</items>
      </items>
      <items code="at0006">
        <items id="text">Regelmäßig</items>
        <items id="description">Der Verlauf ist regelmäßig.</items>
      </items>
      <items code="at0007">
        <items id="text">Normal unregelmäßig</items>
        <items id="description">Der Verlauf ist unregelmäßig, aber in einem regelmäßigen Muster. Zum Beispiel das Ausfallen eines Schlages alle "n" Schläge.</items>
      </items>
      <items code="at0008">
        <items id="text">Ungleichmäßig unregelmäßig</items>
        <items id="description">Der Verlauf ist auf chaotische und unvorhersehbare Weise unregelmäßig. Zum Beispiel: Vorhofflimmern.</items>
      </items>
      <items code="at0010">
        <items id="text">List</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0012">
        <items id="text">List</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0013">
        <items id="text">Körperhaltung</items>
        <items id="description">Die Körperhaltung des Patienten während der Untersuchung.</items>
      </items>
      <items code="at1000">
        <items id="text">Liegend</items>
        <items id="description">Der Patient lag flach.</items>
      </items>
      <items code="at1001">
        <items id="text">Sitzend</items>
        <items id="description">Der Patient saß (zum Beispiel auf einem Bett oder einem Stuhl).</items>
      </items>
      <items code="at1002">
        <items id="text">Zurücklehnend</items>
        <items id="description">Der Patient saß zurück gelehnt in einem Winkel von 45 Grad und seine Beine waren bis zur Höhe des Beckens angehoben.</items>
      </items>
      <items code="at1003">
        <items id="text">Stehend/Aufrecht</items>
        <items id="description">Der Patient stand, ging oder rannte.</items>
      </items>
      <items code="at1005">
        <items id="text">Vorhandensein</items>
        <items id="description">Vorhandensein einer Puls- oder Herzfrequenz.</items>
        <items id="comment">Eine Puls-/Herzfrequenz ist vorhanden, wenn die Frequenz &gt; 0 Schläge pro Minute ist.</items>
      </items>
      <items code="at1013">
        <items id="text">Gerät</items>
        <items id="description">Informationen zu dem Gerät, welches zur Messung der Puls- oder der Herzfrequenz verwendet wurde.</items>
      </items>
      <items code="at1017">
        <items id="text">Anstrengung</items>
        <items id="description">Details über die körperliche Anstrengung, die der Patient während der Untersuchung ausgesetzt war.</items>
      </items>
      <items code="at1018">
        <items id="text">Störfaktoren</items>
        <items id="description">Die Beschreibung aller zufälligen Faktoren, die die Interpretation der physikalischen Ergebnisse beeinflussen können.</items>
        <items id="comment">Zum Beispiel das Vorhandensein eines Herzschrittmacher; das Angstniveau; Schmerzen oder Fieber etc.</items>
      </items>
      <items code="at1019">
        <items id="text">Methode</items>
        <items id="description">Die Methode, mit der die Puls- oder Herzfrequenz gemessen wurde.</items>
        <items id="comment">Zum Beispiel auskultatorisch oder über elektronisches Monitoring, z.B. mit einem Blutdruckmessgerät.</items>
      </items>
      <items code="at1022">
        <items id="text">Klinische Beschreibung</items>
        <items id="description">Beschreibung der Puls- oder Herzfrequenz.</items>
      </items>
      <items code="at1023">
        <items id="text">Klinische Interpretation</items>
        <items id="description">Ein einzelnes Wort, ein Satz oder eine kurze Beschreibung, welches die klinische Bedeutung und die Signifikanz der Puls- oder der Herzfrequenz, einschließlich des Rhythmus, darstellt.</items>
        <items id="comment">Die Kodierung mit einer Terminologie wird, wenn möglich, bevorzugt. Zum Beispiel: Bradykardie, Extrasystolen oder Sinusrhythmus. Mehrere Aussagen sind erlaubt.</items>
      </items>
      <items code="at1024">
        <items id="text">Vorhanden</items>
        <items id="description">Eine Puls- oder eine Herzfrequenz kann ermittelt werden.</items>
      </items>
      <items code="at1025">
        <items id="text">Nicht ermittelbar</items>
        <items id="description">Eine Puls- oder eine Herzfrequenz kann nicht ermittelt werden.</items>
      </items>
      <items code="at1028">
        <items id="text">Unregelmäßig</items>
        <items id="description">Der Verlauf ist unregelmäßig.</items>
      </items>
      <items code="at1030">
        <items id="text">Merkmal</items>
        <items id="description">Beschreibung des Merkmals der Puls- oder Herzfrequenz.</items>
        <items id="comment">Die Kodierung mit einer Terminologie ist, wenn möglich, erwünscht. Zum Beispiel: kräftig, schwach, hämmernd, langsam ansteigend oder kollabierend. Mehrere Begriffe können dokumentiert werden.</items>
      </items>
      <items code="at1032">
        <items id="text">Palpation</items>
        <items id="description">Der Befund wurde durch physisches Tasten des Beobachters am Patienten erlangt.</items>
      </items>
      <items code="at1033">
        <items id="text">Auskultation</items>
        <items id="description">Die Untersuchungsergebnisse werden mit Hilfe eines Gerätes, wie zum Beispiel einem Stethoskop, gemessen.</items>
      </items>
      <items code="at1034">
        <items id="text">Automatisch, nicht-invasiv</items>
        <items id="description">Die Untersuchungsergebnisse werden nicht-invasiv unter Anwendung eines Gerätes, wie zum Beispiel mit Hilfe eines Pulsoximeters oder eines Stethoskops, gemessen.</items>
      </items>
      <items code="at1036">
        <items id="text">Maximum</items>
        <items id="description">Die maximale Puls- oder Herzfrequenz, die während einer Belastungsperiode gemessen wurde.</items>
      </items>
      <items code="at1037">
        <items id="text">Körperstelle</items>
        <items id="description">Die Körperstelle an der die Puls- oder die Herzfrequenz gemessen wird.</items>
      </items>
      <items code="at1038">
        <items id="text">Arteria radialis - links</items>
        <items id="description">Die linke Arteria radialis.</items>
      </items>
      <items code="at1039">
        <items id="text">Arteria radialis - rechts</items>
        <items id="description">Die rechte Arteria radialis.</items>
      </items>
      <items code="at1040">
        <items id="text">Herz</items>
        <items id="description">Die Region des Herzens.</items>
      </items>
      <items code="at1041">
        <items id="text">Arteria carotis - links</items>
        <items id="description">Die linke Arteria carotis.</items>
      </items>
      <items code="at1042">
        <items id="text">Arteria carotis - rechts</items>
        <items id="description">Die rechte Arteria carotis.</items>
      </items>
      <items code="at1043">
        <items id="text">Arteria femoralis - links</items>
        <items id="description">Die linke Arteria femoralis.</items>
      </items>
      <items code="at1044">
        <items id="text">Arteria femoralis - rechts</items>
        <items id="description">Die rechts Arteria femoralis.</items>
      </items>
      <items code="at1047">
        <items id="text">Finger</items>
        <items id="description">Ein nicht näher beschriebener Finger.</items>
      </items>
      <items code="at1048">
        <items id="text">Arteria brachialis - links</items>
        <items id="description">Die linke Arteria brachialis.</items>
      </items>
      <items code="at1049">
        <items id="text">Arteria brachialis - rechts</items>
        <items id="description">Die rechte Arteria brachialis.</items>
      </items>
      <items code="at1050">
        <items id="text">Automatisch, invasiv</items>
        <items id="description">Die Untersuchungsergebnisse werden invasiv durch die Verwendung eines Gerätes, wie zum Beispiel eines arteriellen Katheters, gemessen.</items>
      </items>
      <items code="at1051">
        <items id="text">Ohrläppchen</items>
        <items id="description">Das Ohrläppchen eines unbestimmten Ohres.</items>
      </items>
      <items code="at1054">
        <items id="text">Zeh</items>
        <items id="description">Ein nicht näher beschriebener Zeh.</items>
      </items>
      <items code="at1055">
        <items id="text">Unregelmäßiger Typ</items>
        <items id="description">Ein spezifischeres Verlaufsmuster einer unregelmäßigen Puls- oder Herzfrequenz.</items>
        <items id="comment">Die Auswahl eines Wertes dieser Wertemenge ist nur valide, wenn "Unregelmäßig" vom Datenelement "Regelmäßigkeit" angegeben wurde.</items>
      </items>
      <items code="at1056">
        <items id="text">Erweiterung</items>
        <items id="description">Zusätzliche Informationen zur Erfassung lokaler Inhalte oder Anpassung an andere Referenzmodelle/Formalismen.</items>
        <items id="comment">Zum Beispiel: Lokaler Informationsbedarf oder zusätzliche Metadaten zur Anpassung an FHIR-Ressourcen oder CIMI-Modelle.</items>
      </items>
      <items code="at1057">
        <items id="text">Klinische Interpretation</items>
        <items id="description">Eine allgemeine Bezeichnung, um alle oder einen Teil der Aussagen über die Puls- oder die Herzfrequenz zu ermöglichen.</items>
      </items>
      <items code="at1058">
        <items id="text">Rhythmus</items>
        <items id="description">Spezifische Schlussfolgerung über den Rhythmus der Puls- oder der Herzfrequenz, die sich aus einer Kombination von Herzfrequenz, dem Verlaufsmuster und anderen bei der Untersuchung beobachteten Merkmalen ergibt.</items>
      </items>
      <items code="at1059">
        <items id="text">Kommentar</items>
        <items id="description">Zusätzliche Informationen über die Puls- oder die Herzfrequenz, die in anderen Bereichen nicht erfasst wurden.</items>
      </items>
    </term_definitions>
    <term_definitions language="ru">
      <items code="at0000">
        <items id="text">*Pulse/Heart beat(en)</items>
        <items id="description">*The rate and associated attributes for a pulse or heart beat. (en)</items>
      </items>
      <items code="at0001">
        <items id="text">Дерево</items>
        <items id="description">@ внутреннийl @</items>
      </items>
      <items code="at0002">
        <items id="text">История</items>
        <items id="description">@ внутреннийl @</items>
      </items>
      <items code="at0003">
        <items id="text">*Any event(en)</items>
        <items id="description">*Default, unspecified point in time or interval event which may be explicitly defined in a template or at run-time.(en)</items>
      </items>
      <items code="at0004">
        <items id="text">*Rate(en)</items>
        <items id="description">*The rate of the pulse or heart beat, measured in beats per minute. (en)</items>
      </items>
      <items code="at0005">
        <items id="text">*Regular?(en)</items>
        <items id="description">*Is the pulse or heart beat regular?(en)</items>
      </items>
      <items code="at0006">
        <items id="text">*Regular(en)</items>
        <items id="description">*The pattern is regular.(en)</items>
      </items>
      <items code="at0007">
        <items id="text">*Regularly Irregular(en)</items>
        <items id="description">*The pattern is irregular in a regular pattern,. For example, a dropped beat once every 'n' beats.(en)</items>
      </items>
      <items code="at0008">
        <items id="text">*Irregularly Irregular(en)</items>
        <items id="description">*The pattern is irregular in a chaotic and unpredictable manner. For example, atrial fibrillation.(en)</items>
      </items>
      <items code="at0010">
        <items id="text">Дерево</items>
        <items id="description">@ внутреннийl @</items>
      </items>
      <items code="at0012">
        <items id="text">Дерево</items>
        <items id="description">@ внутреннийl @</items>
      </items>
      <items code="at0013">
        <items id="text">*Position(en)</items>
        <items id="description">*The body position of the subject during the observation.(en)</items>
      </items>
      <items code="at1000">
        <items id="text">*Lying(en)</items>
        <items id="description">*The subject was lying flat.(en)</items>
      </items>
      <items code="at1001">
        <items id="text">*Sitting(en)</items>
        <items id="description">*The subject was sitting (for example on bed or chair).(en)</items>
      </items>
      <items code="at1002">
        <items id="text">*Reclining(en)</items>
        <items id="description">*The subject was reclining at an approximate angle of 45 degrees, with the legs elevated to the level of the pelvis.(en)</items>
      </items>
      <items code="at1003">
        <items id="text">*Standing/upright(en)</items>
        <items id="description">*The subject was standing, walking or running.(en)</items>
      </items>
      <items code="at1005">
        <items id="text">*Presence(en)</items>
        <items id="description">*Presence of a pulse or heart beat.(en)</items>
        <items id="comment">*It can be implied that the pulse or heart beat is present if Rate &gt;0 /min. (en)</items>
      </items>
      <items code="at1013">
        <items id="text">*Device(en)</items>
        <items id="description">*Details about the device used to measure the pulse rate or heart rate.(en)</items>
      </items>
      <items code="at1017">
        <items id="text">*Exertion(en)</items>
        <items id="description">*Details about physical exertion being undertaken during the examination.(en)</items>
      </items>
      <items code="at1018">
        <items id="text">*Confounding factors(en)</items>
        <items id="description">*Narrative description about any incidental factors that may affect interpretation of the physical findings.(en)</items>
        <items id="comment">*For example, presence of a pacemaker, level of anxiety; pain or fever etc.(en)</items>
      </items>
      <items code="at1019">
        <items id="text">*Method(en)</items>
        <items id="description">*Method used to observe the pulse or heart beat.(en)</items>
        <items id="comment">*For example, auscultation or electronic monitoring. (en)</items>
      </items>
      <items code="at1022">
        <items id="text">*Clinical description(en)</items>
        <items id="description">*Narrative description about the pulse or heart beat.(en)</items>
      </items>
      <items code="at1023">
        <items id="text">*Clinical interpretation(en)</items>
        <items id="description">*Single word, phrase or brief description that represents the clinical meaning and significance of the pulse or heart beat findings, including the rhythm.(en)</items>
        <items id="comment">*Coding with a terminology is preferred, where possible. For example: Bradycardia, Extrasystoles or Sinus rhythm. Multiple statements are allowed. (en)</items>
      </items>
      <items code="at1024">
        <items id="text">*Present(en)</items>
        <items id="description">*A pulse or heart beat can be detected.(en)</items>
      </items>
      <items code="at1025">
        <items id="text">*Not detected(en)</items>
        <items id="description">*A pulse or heart beat cannot be detected.(en)</items>
      </items>
      <items code="at1028">
        <items id="text">*Irregular(en)</items>
        <items id="description">*The pattern is irregular.(en)</items>
      </items>
      <items code="at1030">
        <items id="text">*Character(en)</items>
        <items id="description">*Description of the character of the pulse or heart beat.(en)</items>
        <items id="comment">*Coding with a terminology is desired, where possible. For example: full, thready, bounding, slow rising, or collapsing. Multiple terms may be recorded.(en)</items>
      </items>
      <items code="at1032">
        <items id="text">*Palpation(en)</items>
        <items id="description">*The findings are observed by physical touch of the observer on the subject.(en)</items>
      </items>
      <items code="at1033">
        <items id="text">*Auscultation(en)</items>
        <items id="description">*The findings are observed with the assistance of a device, such as a stethoscope.(en)</items>
      </items>
      <items code="at1034">
        <items id="text">*Automatic, non-invasive(en)</items>
        <items id="description">*The findings are observed non-invasively using a device such as a pulse oximeter or a stethoscope.(en)</items>
      </items>
      <items code="at1036">
        <items id="text">*Maximum(en)</items>
        <items id="description">*Maximum pulse rate or heart rate observed during a period of exertion.(en)</items>
      </items>
      <items code="at1037">
        <items id="text">*Body site(en)</items>
        <items id="description">*Body site where the pulse or heart beat were observed.(en)</items>
      </items>
      <items code="at1038">
        <items id="text">*Radial Artery - Left(en)</items>
        <items id="description">*The left radial artery.(en)</items>
      </items>
      <items code="at1039">
        <items id="text">*Radial Artery - Right(en)</items>
        <items id="description">*The right radial artery.(en)</items>
      </items>
      <items code="at1040">
        <items id="text">*Heart(en)</items>
        <items id="description">*The region of the heart.(en)</items>
      </items>
      <items code="at1041">
        <items id="text">*Carotid Artery - Left(en)</items>
        <items id="description">*The left carotid artery.(en)</items>
      </items>
      <items code="at1042">
        <items id="text">*Carotid Artery - Right(en)</items>
        <items id="description">*The right carotid artery.(en)</items>
      </items>
      <items code="at1043">
        <items id="text">*Femoral Artery - Left(en)</items>
        <items id="description">*The left femoral artery.(en)</items>
      </items>
      <items code="at1044">
        <items id="text">*Femoral Artery - Right(en)</items>
        <items id="description">*The right femoral artery.(en)</items>
      </items>
      <items code="at1047">
        <items id="text">*Finger(en)</items>
        <items id="description">*An unspecified finger.(en)</items>
      </items>
      <items code="at1048">
        <items id="text">*Brachial artery - Left(en)</items>
        <items id="description">*The left brachial artery.(en)</items>
      </items>
      <items code="at1049">
        <items id="text">*Brachial artery - Right(en)</items>
        <items id="description">*The right brachial artery.(en)</items>
      </items>
      <items code="at1050">
        <items id="text">*Automatic, invasive(en)</items>
        <items id="description">*The findings are observed invasively using a device such as an arterial catheter.(en)</items>
      </items>
      <items code="at1051">
        <items id="text">*Ear lobe(en)</items>
        <items id="description">*The lobe of an unspecified ear.(en)</items>
      </items>
      <items code="at1054">
        <items id="text">*Toe(en)</items>
        <items id="description">*An unspecified toe.(en)</items>
      </items>
      <items code="at1055">
        <items id="text">*Irregular type(en)</items>
        <items id="description">*More specific pattern of an irregular pulse or heart beat.(en)</items>
        <items id="comment">*Selection of a value from this value set is only valid if 'Irregular' is selected from the 'Regularity' data element.(en)</items>
      </items>
      <items code="at1056">
        <items id="text">*Extension(en)</items>
        <items id="description">*Additional information required to capture local content or to align with other reference models/formalisms.(en)</items>
        <items id="comment">*For example: local information requirements or additional metadata to align with FHIR or CIMI equivalents.(en)</items>
      </items>
      <items code="at1057">
        <items id="text">*Clinical interpretation(en)</items>
        <items id="description">*Generic label to allow for any or all statements about the pulse or heart beat.(en)</items>
      </items>
      <items code="at1058">
        <items id="text">*Rhythm(en)</items>
        <items id="description">*Specific conclusion about the rhythm of the pulse or heartbeat, drawn from a combination of the heart rate, pattern and other characteristics observed on examination.(en)</items>
      </items>
      <items code="at1059">
        <items id="text">*Comment(en)</items>
        <items id="description">*Additional narrative about the pulse or heart beat findings not captured in other fields.(en)</items>
      </items>
    </term_definitions>
    <term_definitions language="pt-br">
      <items code="at0000">
        <items id="text">Pulso/Batimento Cardíaco</items>
        <items id="description">*The rate and associated attributes for a pulse or heart beat. (en)</items>
      </items>
      <items code="at0001">
        <items id="text">structure</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0002">
        <items id="text">history</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0003">
        <items id="text">Algum evento</items>
        <items id="description">Predefinido, ponto não especificado ou evento de intervalo que pode ser explicitamente definido em um modelo ou em tempo de execução.</items>
      </items>
      <items code="at0004">
        <items id="text">Frequência</items>
        <items id="description">*The rate of the pulse or heart beat, measured in beats per minute. (en)</items>
      </items>
      <items code="at0005">
        <items id="text">Regular?</items>
        <items id="description">O pulso ou frequência cardíaca é regular?</items>
      </items>
      <items code="at0006">
        <items id="text">Regular</items>
        <items id="description">O padrão é regular.</items>
      </items>
      <items code="at0007">
        <items id="text">Irregular regularmente</items>
        <items id="description">O padrão é irregular em um padrão regular. Por exemplo: a cada "n" batimentos existe uma irregularidade.</items>
      </items>
      <items code="at0008">
        <items id="text">Irregular irregularmente</items>
        <items id="description">O padrão é irregular de forma caótica e imprevisível. Por exemplo, fibrilação atrial.</items>
      </items>
      <items code="at0010">
        <items id="text">List</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0012">
        <items id="text">List</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0013">
        <items id="text">Posição</items>
        <items id="description">A posição do corpo do sujeito da atenção durante a observação.</items>
      </items>
      <items code="at1000">
        <items id="text">Deitado</items>
        <items id="description">O sujeito estava deitado.</items>
      </items>
      <items code="at1001">
        <items id="text">Sentado</items>
        <items id="description">O sujeito estava sentado (por exemplo, na cama ou cadeira)</items>
      </items>
      <items code="at1002">
        <items id="text">Reclinado</items>
        <items id="description">O sujeito estava reclinado em um ângulo aproximado de 45°, com as pernas elevadas ao nível da pelve.</items>
      </items>
      <items code="at1003">
        <items id="text">Em pé</items>
        <items id="description">O sujeito estava em pé, andando ou correndo.</items>
      </items>
      <items code="at1005">
        <items id="text">Presença</items>
        <items id="description">Presença de pulso ou batimento cardíaco.</items>
        <items id="comment">*It can be implied that the pulse or heart beat is present if Rate &gt;0 /min. (en)</items>
      </items>
      <items code="at1013">
        <items id="text">Dispositivo</items>
        <items id="description">Detalhes sobre o dispositivo usado para mensurar a frequência do pulso ou frequência cardíaca.</items>
      </items>
      <items code="at1017">
        <items id="text">Esforço</items>
        <items id="description">Detalhes sobre o esforço físico que está sendo realizado durante o exame.</items>
      </items>
      <items code="at1018">
        <items id="text">Fatores de confusão</items>
        <items id="description">Descrição narrativa sobre quaisquer fatores incidentais que possam afetar a interpretação dos achados físicos.</items>
        <items id="comment">Por exemplo, presença de marcapasso, nível de ansiedade, dor ou febre, etc.</items>
      </items>
      <items code="at1019">
        <items id="text">Método</items>
        <items id="description">Método utilizado para observar o pulso ou frequência cardíaca.</items>
        <items id="comment">Por exemplo, ausculta ou monitorização eletrônica.</items>
      </items>
      <items code="at1022">
        <items id="text">Descrição clínica</items>
        <items id="description">Narrativa da descrição sobre o pulso ou batimento cardíaco.</items>
      </items>
      <items code="at1023">
        <items id="text">Interpretação clínica</items>
        <items id="description">Palavra única, frase ou breve descrição que representa o significado clínico e significância do pulso ou batimento cardíaco, incluindo o ritmo.</items>
        <items id="comment">A codificação com uma terminologia é preferida, quando possível. Por exemplo: bradicardia, extrassístoles ou ritmo sinusal. São permitidas várias afirmações.</items>
      </items>
      <items code="at1024">
        <items id="text">Presente</items>
        <items id="description">Um pulso ou batimento cardíaco podem ser detectados.</items>
      </items>
      <items code="at1025">
        <items id="text">Não detectado</items>
        <items id="description">Um pulso ou batimento cardíaco não podem ser detectados.</items>
      </items>
      <items code="at1028">
        <items id="text">Irregular</items>
        <items id="description">O padrão é irregular.</items>
      </items>
      <items code="at1030">
        <items id="text">Característica</items>
        <items id="description">Descrição da característica do pulso ou batimento cardíaco.</items>
        <items id="comment">A codificação com uma terminologia é desejada, quando possível. Por exemplo: cheio, filiforme, delimitado, aumento lento ou em colapso. Múltiplos termos podem ser registrados.</items>
      </items>
      <items code="at1032">
        <items id="text">Palpação</items>
        <items id="description">Os resultados são observados pelo toque físico no sujeito do cuidado pelo observador.</items>
      </items>
      <items code="at1033">
        <items id="text">Ausculta</items>
        <items id="description">Os resultados são observados com a ajuda de um dispositivo, como um estetoscópio.</items>
      </items>
      <items code="at1034">
        <items id="text">Automática, não invasiva</items>
        <items id="description">Os resultados são observados de forma não invasiva utilizando um dispositivo como um oxímetro de pulso ou um estetoscópio.</items>
      </items>
      <items code="at1036">
        <items id="text">Máximo</items>
        <items id="description">Frequência de pulso ou frequência cardíaca máximos observados durante o período de esforço.</items>
      </items>
      <items code="at1037">
        <items id="text">Local do corpo</items>
        <items id="description">Local do corpo onde o pulso ou batimento cardíaco foram observados.</items>
      </items>
      <items code="at1038">
        <items id="text">Artéria Radial - Esquerda</items>
        <items id="description">A artéria radial esquerda.</items>
      </items>
      <items code="at1039">
        <items id="text">Artéria Radial Direita</items>
        <items id="description">A artéria radial direita.</items>
      </items>
      <items code="at1040">
        <items id="text">Coração</items>
        <items id="description">A região do coração.</items>
      </items>
      <items code="at1041">
        <items id="text">Artéria Carótida Esquerda</items>
        <items id="description">A artéria carótida esquerda.</items>
      </items>
      <items code="at1042">
        <items id="text">Artéria Carótida Direita</items>
        <items id="description">A artéria carótida direita.</items>
      </items>
      <items code="at1043">
        <items id="text">Artéria Femural Esquerda</items>
        <items id="description">A artéria femural esquerda.</items>
      </items>
      <items code="at1044">
        <items id="text">Artéria femural Direita</items>
        <items id="description">A artéria femural direita.</items>
      </items>
      <items code="at1047">
        <items id="text">Dedo</items>
        <items id="description">Um dedo inespecífico.</items>
      </items>
      <items code="at1048">
        <items id="text">Artéria Braquial Esquerda</items>
        <items id="description">A artéria braquial esquerda.</items>
      </items>
      <items code="at1049">
        <items id="text">Artéria Braquial Direita</items>
        <items id="description">A artéria braquial direita.</items>
      </items>
      <items code="at1050">
        <items id="text">Automática, invasiva</items>
        <items id="description">Os achados são observados de forma invasiva utilizando um dispositivo como um catéter arterial.</items>
      </items>
      <items code="at1051">
        <items id="text">Lobo da orelha</items>
        <items id="description">Um lobo da orelha inespecífico.</items>
      </items>
      <items code="at1054">
        <items id="text">Dedo do pé</items>
        <items id="description">Um dedo do pé inespecífico.</items>
      </items>
      <items code="at1055">
        <items id="text">Tipo irregular</items>
        <items id="description">Padrão mais específico de um pulso ou batimento cardíaco irregular.</items>
        <items id="comment">A seleção de um valor a partir deste conjunto de valores só é válida se 'Irregular' for selecionado a partir do elemento de dados 'Regularidade'.</items>
      </items>
      <items code="at1056">
        <items id="text">Extensão</items>
        <items id="description">Informações adicionais necessárias para capturar conteúdo local ou alinhar com outros modelos/formalismos de referência.</items>
        <items id="comment">Por exemplo: requisitos de informação local ou metadados adicionais para alinhar com equivalentes FHIR ou CIMI.</items>
      </items>
      <items code="at1057">
        <items id="text">Interpretação clínica</items>
        <items id="description">Etiqueta genérica para permitir qualquer ou todas as declarações sobre o pulso ou batimento cardíaco.</items>
      </items>
      <items code="at1058">
        <items id="text">Ritmo</items>
        <items id="description">Conclusão específica sobre o ritmo do pulso ou batimento cardíaco, extraído de uma combinação da freqüência cardíaca, padrão e outras características observadas no exame.</items>
      </items>
      <items code="at1059">
        <items id="text">Comentários</items>
        <items id="description">Narrativa adicional sobre o pulso ou batimento cardíaco achados não capturados em outros campos.</items>
      </items>
    </term_definitions>
    <term_definitions language="sv">
      <items code="at0000">
        <items id="text">Puls/Hjärtslag</items>
        <items id="description">Pulsen eller hjärtslagens frekvens och tillhörande attribut.</items>
      </items>
      <items code="at0001">
        <items id="text">structure</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0002">
        <items id="text">history</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0003">
        <items id="text">Ospecificerad händelse</items>
        <items id="description">Ospecificerad standardhändelse vid en tidpunkt eller inom ett tidsintervall som explicit kan definieras i en template eller genereras automatiskt av vissa IT-system.</items>
      </items>
      <items code="at0004">
        <items id="text">Frekvens</items>
        <items id="description">Frekvensen av pulsen eller hjärtslagen, mätt i slag per minut.</items>
      </items>
      <items code="at0005">
        <items id="text">Regelbundenhet</items>
        <items id="description">Regelbundenhet hos pulsen eller hjärtslagen.</items>
      </items>
      <items code="at0006">
        <items id="text">Regelbunden</items>
        <items id="description">Mönstret är regelbundet.</items>
      </items>
      <items code="at0007">
        <items id="text">Regelbundet oregelbunden</items>
        <items id="description">Mönstret är oregelbundet i ett regelbundet mönster, exempelvis ett överhoppat hjärtslag var N:te slag.</items>
      </items>
      <items code="at0008">
        <items id="text">Oregelbundet oregelbunden</items>
        <items id="description">Mönstret är oregelbundet på ett kaotiskt och oförutsägbart sätt, exempelvis förmaksflimmer.</items>
      </items>
      <items code="at0010">
        <items id="text">List</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0012">
        <items id="text">List</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0013">
        <items id="text">Kroppsställning</items>
        <items id="description">Individens kroppsställning under observationen.</items>
      </items>
      <items code="at1000">
        <items id="text">Liggande</items>
        <items id="description">Individen låg raklång.</items>
      </items>
      <items code="at1001">
        <items id="text">Sittande</items>
        <items id="description">Individen satt, exempelvis på en säng eller en stol.</items>
      </items>
      <items code="at1002">
        <items id="text">Halvliggande</items>
        <items id="description">Individen låg i ungefär 45 graders vinkel, med benen upphöjda till bäckennivå.</items>
      </items>
      <items code="at1003">
        <items id="text">Stående eller upprätt</items>
        <items id="description">Individen stod upprätt, gick eller sprang.</items>
      </items>
      <items code="at1005">
        <items id="text">Närvaro</items>
        <items id="description">Närvaro av puls eller hjärtslag.</items>
        <items id="comment">Det kan antas att puls eller hjärtslag är närvarande om frekvensen är &gt;0 /min.</items>
      </items>
      <items code="at1013">
        <items id="text">Utrustning</items>
        <items id="description">Information om den utrustning som använts för att mäta puls eller hjärtfrekvens.</items>
      </items>
      <items code="at1017">
        <items id="text">Ansträngning</items>
        <items id="description">Uppgifter om fysisk ansträngning under undersökningen.</items>
      </items>
      <items code="at1018">
        <items id="text">Möjliga felkällor</items>
        <items id="description">Beskrivning av faktorer som kan påverka tolkningen av de fysiska fynden.</items>
        <items id="comment">Exempelvis närvaro av pacemaker, grad av oro, smärta eller feber.</items>
      </items>
      <items code="at1019">
        <items id="text">Metod</items>
        <items id="description">Metod som användes för att observera pulsen eller hjärtslagen.</items>
        <items id="comment">Exempelvis auskultation eller elektronisk övervakning.</items>
      </items>
      <items code="at1022">
        <items id="text">Klinisk beskrivning</items>
        <items id="description">Beskrivning av pulsen eller hjärtslagen.</items>
      </items>
      <items code="at1023">
        <items id="text">Klinisk tolkning</items>
        <items id="description">Enstaka ord, fras eller kort beskrivning om den kliniska innebörden och betydelsen av fynd från puls eller hjärtslag, inklusive rytm.</items>
        <items id="comment">Kodning med en terminologi är att föredra, om möjligt. Exempelvis takykardi, bradykardi, förmaksflimmer, prematura slag eller sinusrytm med extraslag. Flera utlåtanden är tillåtna.</items>
      </items>
      <items code="at1024">
        <items id="text">Närvaro</items>
        <items id="description">Puls eller hjärtslag kan detekteras.</items>
      </items>
      <items code="at1025">
        <items id="text">Frånvaro</items>
        <items id="description">Puls eller hjärtslag kan inte detekteras.</items>
      </items>
      <items code="at1028">
        <items id="text">Oregelbunden</items>
        <items id="description">Mönstret är oregelbundet.</items>
      </items>
      <items code="at1030">
        <items id="text">Karaktär</items>
        <items id="description">Beskrivning av pulsens eller hjärtslagets karaktär.</items>
        <items id="comment">Kodning med en terminologi är önskvärd, om möjligt. Exempelvis fyllig, svag, kraftig, långsamt stigande eller kollapsande. Flera termer kan registreras.</items>
      </items>
      <items code="at1032">
        <items id="text">Palpation</items>
        <items id="description">Fynden observeras genom fysisk beröring av individen.</items>
      </items>
      <items code="at1033">
        <items id="text">Auskultation</items>
        <items id="description">Fynden observeras med ett hjälpmedel, exempelvis ett stetoskop.</items>
      </items>
      <items code="at1034">
        <items id="text">Automatisk, icke-invasiv</items>
        <items id="description">Fynden observeras icke-invasivt med hjälp av utrustning såsom en pulsoximeter eller ett stetoskop.</items>
      </items>
      <items code="at1036">
        <items id="text">Maximum</items>
        <items id="description">Maxpuls eller maxfrekvens observerad under ansträngning.</items>
      </items>
      <items code="at1037">
        <items id="text">Kroppslokalisation</items>
        <items id="description">Lokalisation där pulsen eller hjärtslagen observerades.</items>
      </items>
      <items code="at1038">
        <items id="text">Radialisartär - Vänster</items>
        <items id="description">Vänstra radialisartären.</items>
      </items>
      <items code="at1039">
        <items id="text">Radialisartär - Höger</items>
        <items id="description">Högra radialisartären.</items>
      </items>
      <items code="at1040">
        <items id="text">Hjärta</items>
        <items id="description">Hjärtområdet.</items>
      </items>
      <items code="at1041">
        <items id="text">Carotisartär – Vänster</items>
        <items id="description">Vänstra carotisartären.</items>
      </items>
      <items code="at1042">
        <items id="text">Carotisartär - Höger</items>
        <items id="description">Högra carotisartären.</items>
      </items>
      <items code="at1043">
        <items id="text">Femoralartär - Vänster</items>
        <items id="description">Vänstra femoralartären.</items>
      </items>
      <items code="at1044">
        <items id="text">Femoralartär - Höger</items>
        <items id="description">Högra femoralartären.</items>
      </items>
      <items code="at1047">
        <items id="text">Finger</items>
        <items id="description">Ospecificerat finger.</items>
      </items>
      <items code="at1048">
        <items id="text">Brachialartär - Vänster</items>
        <items id="description">Vänstra brachialartären.</items>
      </items>
      <items code="at1049">
        <items id="text">Brachialartär - Höger</items>
        <items id="description">Högra brachialartären.</items>
      </items>
      <items code="at1050">
        <items id="text">Automatisk, invasiv</items>
        <items id="description">Fynden observeras invasivt med hjälp av utrustning såsom en arteriell kateter.</items>
      </items>
      <items code="at1051">
        <items id="text">Öronlob</items>
        <items id="description">Loben på ospecificerat öra.</items>
      </items>
      <items code="at1054">
        <items id="text">Tå</items>
        <items id="description">Ospecificerad tå.</items>
      </items>
      <items code="at1055">
        <items id="text">Typ av oregelbundenhet</items>
        <items id="description">Ett mer specifikt mönster av oregelbunden puls eller oregelbundna hjärtslag.</items>
        <items id="comment">Ett val från den här värdemängden är endast giltigt om "oregelbunden" väljs från komponenten "regelbunden".</items>
      </items>
      <items code="at1056">
        <items id="text">Tilläggsinformation</items>
        <items id="description">Plats för tilläggsinformation som krävs för lokala anpassningar eller anpassning till andra referensmodeller eller formella krav.</items>
        <items id="comment">Exempelvis lokala informationskrav eller metadata för anpassning till FHIR.</items>
      </items>
      <items code="at1057">
        <items id="text">Klinisk tolkning</items>
        <items id="description">Allmänt datafält för ett enskilt eller samtliga utlåtanden om pulsen eller hjärtrytmen.</items>
      </items>
      <items code="at1058">
        <items id="text">Rytm</items>
        <items id="description">Specifik slutsats om pulsens eller hjärtslagens rytm, härledd från en kombination av hjärtfrekvens, mönster och andra egenskaper som observerats vid undersökningen.</items>
      </items>
      <items code="at1059">
        <items id="text">Kommentar</items>
        <items id="description">Ytterligare beskrivning av fynden från puls eller hjärtslag som inte beskrivits i andra fält.</items>
      </items>
    </term_definitions>
    <term_definitions language="es">
      <items code="at0000">
        <items id="text">Pulso/Frecuencia cardiaca</items>
        <items id="description">La frecuencia y los atributos asociados al pulso o latido del corazón.</items>
      </items>
      <items code="at0001">
        <items id="text">estructura</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0002">
        <items id="text">historia</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0003">
        <items id="text">Cualquier evento</items>
        <items id="description">Evento predeterminado, de punto en el tiempo o intervalo no especificado que puede definirse explícitamente en una plantilla o en tiempo de ejecución.</items>
      </items>
      <items code="at0004">
        <items id="text">Frecuencia</items>
        <items id="description">La frecuencia del pulso o latido del corazón, medida en latidos por minuto.</items>
      </items>
      <items code="at0005">
        <items id="text">Regularidad</items>
        <items id="description">Regularidad del pulso o latido del corazón.</items>
      </items>
      <items code="at0006">
        <items id="text">Regular</items>
        <items id="description">El patrón es regular.</items>
      </items>
      <items code="at0007">
        <items id="text">Regularmente irregular</items>
        <items id="description">El patrón es irregular en un patrón regular. Por ejemplo baja de un latido cada 'n' latidos.</items>
      </items>
      <items code="at0008">
        <items id="text">Irregularmente irregular</items>
        <items id="description">El patrón es irregular, caótico e impredecible. Por ejemplo, la fibrilación auricular.</items>
      </items>
      <items code="at0010">
        <items id="text">lista</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0012">
        <items id="text">lista</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0013">
        <items id="text">Posición</items>
        <items id="description">Posición del cuerpo del sujeto durante la observación.</items>
      </items>
      <items code="at1000">
        <items id="text">Acostado</items>
        <items id="description">El sujeto está acostado de forma horizontal.</items>
      </items>
      <items code="at1001">
        <items id="text">Sentado</items>
        <items id="description">El sujeto estaba sentado (por ejemplo en la cama o en una silla).</items>
      </items>
      <items code="at1002">
        <items id="text">Reclinado</items>
        <items id="description">El sujeto estaba reclinado en un ángulo aproximado a los 45 grados, con las piernas elevadas al nivel de la pelvis.</items>
      </items>
      <items code="at1003">
        <items id="text">De pie</items>
        <items id="description">El sujeto estaba de pie, caminando o corriendo.</items>
      </items>
      <items code="at1005">
        <items id="text">Presencia</items>
        <items id="description">Presencia del pulso o latidos del corazón.</items>
        <items id="comment">Se puede implicar que el pulso o el latido del corazón está presente si la frecuencia &gt; 0 /min.</items>
      </items>
      <items code="at1013">
        <items id="text">Dispositivo</items>
        <items id="description">Detalles sobre el dispositivo utilizado para la medida del pulso o latidos del corazón</items>
      </items>
      <items code="at1017">
        <items id="text">Esfuerzo</items>
        <items id="description">Detalles sobre el esfuerzo físico que se realiza durante el examen.</items>
      </items>
      <items code="at1018">
        <items id="text">Factores de confusión</items>
        <items id="description">Descripción narrativa de cualquier factor incidental que pueda afectar la interpretación de los hallazgos físicos.</items>
        <items id="comment">Por ejemplo, presencia de marcapasos, nivel de ansiedad, dolor o fiebre, etc.</items>
      </items>
      <items code="at1019">
        <items id="text">Método</items>
        <items id="description">Método utilzado para realizar la observación del pulso o latidos del corazón</items>
        <items id="comment">Por ejemplo, auscultación o monitoreo electrónico.</items>
      </items>
      <items code="at1022">
        <items id="text">Descripción clínica</items>
        <items id="description">Descripción narrativa sobre el pulso o latidos cardíacos.</items>
      </items>
      <items code="at1023">
        <items id="text">Interpretación clínica</items>
        <items id="description">Palabra única, frase o breve descripción que representa el significado clínico y significado de los hallazgos sobre el pulso o latidos del corazón, incluyendo el ritmo.</items>
        <items id="comment">Se prefiere codificar con terminología, siempre que sea posible. Por ejemplo: bradicardia, extrasístoles o ritmo sinusal. Se permiten múltiples declaraciones.</items>
      </items>
      <items code="at1024">
        <items id="text">Presente</items>
        <items id="description">Pulso o latidos cardíacos son detectados.</items>
      </items>
      <items code="at1025">
        <items id="text">No detectado</items>
        <items id="description">Pulso o latidos cardíacos no son detectados.</items>
      </items>
      <items code="at1028">
        <items id="text">Irregular</items>
        <items id="description">El patrón es irregular.</items>
      </items>
      <items code="at1030">
        <items id="text">Carácter</items>
        <items id="description">Descripción del carácter del pulso o latidos del corazón.</items>
        <items id="comment">Se recomienda codificar con una terminología, siempre que sea posible. Por ejemplo: completo, filiforme, rebotante, de ascenso lento o colapsante. Se pueden registrar varios términos.</items>
      </items>
      <items code="at1032">
        <items id="text">Palpación</items>
        <items id="description">Los hallazgos se observan mediante el contacto físico del observador sobre el sujeto.</items>
      </items>
      <items code="at1033">
        <items id="text">Auscultación</items>
        <items id="description">Los hallazgos fueron obserbados mediante la asistencia de un dispositivo, como un estetoscopio.</items>
      </items>
      <items code="at1034">
        <items id="text">Automático, no invasivo</items>
        <items id="description">Los hallazgos se observan de forma no invasiva utilizando un dispositivo como un oxímetro de pulso o un estetoscopio.</items>
      </items>
      <items code="at1036">
        <items id="text">Máximo</items>
        <items id="description">Frecuencia máxima de pulso o latidos fue observada durante el período de ejecricio.</items>
      </items>
      <items code="at1037">
        <items id="text">Zona corporal</items>
        <items id="description">Localización corporal donde el pulso o latidos fueron observados.</items>
      </items>
      <items code="at1038">
        <items id="text">Arteria radial - Izquierda</items>
        <items id="description">Arteria radial izquierda.</items>
      </items>
      <items code="at1039">
        <items id="text">Arteria radial - Derecha</items>
        <items id="description">Arteria radial derecha.</items>
      </items>
      <items code="at1040">
        <items id="text">Corazón</items>
        <items id="description">Región del corazón.</items>
      </items>
      <items code="at1041">
        <items id="text">Arteria carótida - Izquierda</items>
        <items id="description">Arteria carótida izquierda.</items>
      </items>
      <items code="at1042">
        <items id="text">Arteria carótida - Derecha</items>
        <items id="description">Arteria carótida derecha.</items>
      </items>
      <items code="at1043">
        <items id="text">Arteria femoral - Izquierda</items>
        <items id="description">Arteria femoral izquierda.</items>
      </items>
      <items code="at1044">
        <items id="text">Arteria femoral - Derecha</items>
        <items id="description">Arteria femoral derecha.</items>
      </items>
      <items code="at1047">
        <items id="text">Dedo de la mano</items>
        <items id="description">Cualquier dedo de la mano.</items>
      </items>
      <items code="at1048">
        <items id="text">Arteria braquial - Izquierda</items>
        <items id="description">Arteria braquial izquierda.</items>
      </items>
      <items code="at1049">
        <items id="text">Arteria braquial - Derecha</items>
        <items id="description">Arteria braquial derecha.</items>
      </items>
      <items code="at1050">
        <items id="text">Automatico, invasivo</items>
        <items id="description">Los hallazgos se observan de forma invasiva utilizando un dispositivo como un catéter arterial.</items>
      </items>
      <items code="at1051">
        <items id="text">Lóbulo de la oreja</items>
        <items id="description">Lóbulo de cualquier oreja.</items>
      </items>
      <items code="at1054">
        <items id="text">Dedo del pie</items>
        <items id="description">Cualquier dedo del pie.</items>
      </items>
      <items code="at1055">
        <items id="text">Tipo irregular</items>
        <items id="description">Patrón más específico de un pulso o latido irregular.</items>
        <items id="comment">La selección de un valor de este conjunto de valores es válida solo si 'irregular' es seleccionado para el elemento 'regularidad'</items>
      </items>
      <items code="at1056">
        <items id="text">Extensión</items>
        <items id="description">Información adicional requerida para capturar contenido local o alinear on otros modelos de referencia.</items>
        <items id="comment">Por ejemplo: requerimientos sobre información local, o metadatos para alinearse con FHIR o CIMI.</items>
      </items>
      <items code="at1057">
        <items id="text">Interpretación clínica</items>
        <items id="description">Etiqueta genérica que permite registrar cualquier declaración sobre el pulso o latidos.</items>
      </items>
      <items code="at1058">
        <items id="text">Ritmo</items>
        <items id="description">Conclusión específica sobre el ritmo del pulso o latido del corazón, extraída de una combinación de la frecuencia cardíaca, el patrón y otras características observadas en el examen.</items>
      </items>
      <items code="at1059">
        <items id="text">Comentario</items>
        <items id="description">Información narrativa adicional sobre hallazgos del pulso o latidos que no fueron registrados en otros campos.</items>
      </items>
    </term_definitions>
    <term_definitions language="fi">
      <items code="at0000">
        <items id="text">Pulssi/syke</items>
        <items id="description">*The rate and associated attributes for a pulse or heart beat. (en)</items>
      </items>
      <items code="at0001">
        <items id="text">structure</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0002">
        <items id="text">history</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0003">
        <items id="text">Mikä tahansa tapahtuma</items>
        <items id="description">Oletusarvoinen, määrittämättömänä ajanhetkenä tai ajanjaksolla ilmenevä tapahtuma, joka voi olla määritetty tarkasti jossakin mallissa tai suorituksen aikana.</items>
      </items>
      <items code="at0004">
        <items id="text">Taajuus</items>
        <items id="description">*The rate of the pulse or heart beat, measured in beats per minute. (en)</items>
      </items>
      <items code="at0005">
        <items id="text">Säännöllinen?</items>
        <items id="description">Onko pulssi tai syke säännöllinen?</items>
      </items>
      <items code="at0006">
        <items id="text">Säännöllinen</items>
        <items id="description">Syke on säännöllinen.</items>
      </items>
      <items code="at0007">
        <items id="text">Säännöllisesti epäsäännöllinen</items>
        <items id="description">Syke on epäsäännöllinen, mutta säännöllisellä tavalla. Esimerkiksi yksittäinen puuttuva lyönti joka n:nnen lyönnin välein.</items>
      </items>
      <items code="at0008">
        <items id="text">Epäsäännöllisesti epäsäännöllinen</items>
        <items id="description">Syke on epäsäännöllinen kaoottisella ja ennustamattomalla tavalla. Esimerkiksi eteisvärinä.</items>
      </items>
      <items code="at0010">
        <items id="text">List</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0012">
        <items id="text">List</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0013">
        <items id="text">Asento</items>
        <items id="description">Tutkittavan kehon asento havainnoinnin aikana.</items>
      </items>
      <items code="at1000">
        <items id="text">Makuulla</items>
        <items id="description">Tutkittava oli makuulla.</items>
      </items>
      <items code="at1001">
        <items id="text">Istuen</items>
        <items id="description">Tutkittava istui (esimerkiksi vuoteella tai tuolissa).</items>
      </items>
      <items code="at1002">
        <items id="text">Taaksepäin nojaten</items>
        <items id="description">Tutkittava nojasi taaksepäin noin 45 asteen kulmassa jalat nostettuina lantion tasalle.</items>
      </items>
      <items code="at1003">
        <items id="text">Seisten/pystyssä</items>
        <items id="description">Tutkittava istui, käveli tai juoksi.</items>
      </items>
      <items code="at1005">
        <items id="text">Läsnäolo</items>
        <items id="description">Pulssin tai sykkeen läsnäolo.</items>
        <items id="comment">*It can be implied that the pulse or heart beat is present if Rate &gt;0 /min. (en)</items>
      </items>
      <items code="at1013">
        <items id="text">Laite</items>
        <items id="description">Tietoja pulssin tai sykkeen mittaamiseen käytetystä laitteesta.</items>
      </items>
      <items code="at1017">
        <items id="text">Rasitus</items>
        <items id="description">Tietoja ruumiillisesta rasituksesta tutkimuksen aikana.</items>
      </items>
      <items code="at1018">
        <items id="text">Sekoittavat tekijät</items>
        <items id="description">Kertomusmuodossa oleva kuvaus satunnaistekijöistä, jotka saattavat vaikuttaa fysikaalisten löydösten tulkintaan.</items>
        <items id="comment">For example, presence of a pacemaker, level of anxiety; pain or fever etc.</items>
      </items>
      <items code="at1019">
        <items id="text">Menetelmä</items>
        <items id="description">Pulssin tai sykkeen havainnointiin käytettävä menetelmä.</items>
        <items id="comment">For example, auscultation or electronic monitoring.</items>
      </items>
      <items code="at1022">
        <items id="text">Kliininen kuvaus</items>
        <items id="description">Kertomusmuodossa oleva kuvaus pulssista tai sykkeestä.</items>
      </items>
      <items code="at1023">
        <items id="text">Kliininen tulkinta</items>
        <items id="description">Yksittäinen sana, fraasi tai lyhyt kuvaus joka edustaa pulssi- tai sykelöydöksen (ml. rytmi) kliinistä merkitystä.</items>
        <items id="comment">Coding with a terminology is preferred, where possible. For example: Bradycardia, Extrasystoles or Sinus rhythm. Multiple statements are allowed.</items>
      </items>
      <items code="at1024">
        <items id="text">Havaittu</items>
        <items id="description">Pulssi tai syke on havaittavissa.</items>
      </items>
      <items code="at1025">
        <items id="text">Ei havaittu</items>
        <items id="description">Pulssi tai syke ei ole havaittavissa.</items>
      </items>
      <items code="at1028">
        <items id="text">Epäsäännöllinen</items>
        <items id="description">Syke on epäsäännöllinen.</items>
      </items>
      <items code="at1030">
        <items id="text">Luonne</items>
        <items id="description">Kuvaus pulssin tai sykkeen luonteesta.</items>
        <items id="comment">Coding with a terminology is desired, where possible. For example: full, thready, bounding, slow rising, or collapsing. Multiple terms may be recorded.</items>
      </items>
      <items code="at1032">
        <items id="text">Palpaatio</items>
        <items id="description">Löydökset havaitaan havaitsijan koskettaessa tutkittavaa fyysisesti.</items>
      </items>
      <items code="at1033">
        <items id="text">Auskultaatio</items>
        <items id="description">Löydökset havaitaan jonkin laitteen avulla, esimerkiksi stetoskoopilla.</items>
      </items>
      <items code="at1034">
        <items id="text">Automaattinen, kajoamaton</items>
        <items id="description">Löydökset havaitaan kajoamattomasti jonkin laitteen avulla, esimerkiksi pulssioksimetrilla tai stetoskoopilla.</items>
      </items>
      <items code="at1036">
        <items id="text">Korkein</items>
        <items id="description">Korkein rasituksen aikana havaittu syke.</items>
      </items>
      <items code="at1037">
        <items id="text">Kehon kohta</items>
        <items id="description">Kehon kohta, josta pulssi tai syke havaittiin.</items>
      </items>
      <items code="at1038">
        <items id="text">Värttinävaltimo – vasen</items>
        <items id="description">Vasen värttinävaltimo.</items>
      </items>
      <items code="at1039">
        <items id="text">Värttinävaltimo – oikea</items>
        <items id="description">Oikea värttinävaltimo.</items>
      </items>
      <items code="at1040">
        <items id="text">Sydän</items>
        <items id="description">Sydämen alue.</items>
      </items>
      <items code="at1041">
        <items id="text">Kaulavaltimo – vasen</items>
        <items id="description">Vasen kaulavaltimo.</items>
      </items>
      <items code="at1042">
        <items id="text">Kaulavaltimo – oikea</items>
        <items id="description">Oikea kaulavaltimo.</items>
      </items>
      <items code="at1043">
        <items id="text">Reisivaltimo – vasen</items>
        <items id="description">Vasen reisivaltimo.</items>
      </items>
      <items code="at1044">
        <items id="text">Reisivaltimo – oikea</items>
        <items id="description">Oikea reisivaltimo.</items>
      </items>
      <items code="at1047">
        <items id="text">Sormi</items>
        <items id="description">Tarkemmin määrittämätön sormi.</items>
      </items>
      <items code="at1048">
        <items id="text">Olkavarsivaltimo - vasen</items>
        <items id="description">Vasen olkavarsivaltimo.</items>
      </items>
      <items code="at1049">
        <items id="text">Olkavarsivaltimo - oikea</items>
        <items id="description">Oikea olkavarsivaltimo.</items>
      </items>
      <items code="at1050">
        <items id="text">Automaattinen, kajoava</items>
        <items id="description">Löydökset havaitaan kajoavasti jonkin laitteen avulla, kuten valtimokatetrilla.</items>
      </items>
      <items code="at1051">
        <items id="text">Korvalehti</items>
        <items id="description">Tarkemmin määrittämätön korvalehti.</items>
      </items>
      <items code="at1054">
        <items id="text">Varvas</items>
        <items id="description">Tarkemmin määrittämätön varvas.</items>
      </items>
      <items code="at1055">
        <items id="text">Tyypiltään epäsäännöllinen</items>
        <items id="description">Epäsäännöllisen pulssin tai sykkeen tarkempi luonnehdinta.</items>
        <items id="comment">Selection of a value from this value set is only valid if 'Irregular' is selected from the 'Regularity' data element.</items>
      </items>
      <items code="at1056">
        <items id="text">Laajennus</items>
        <items id="description">Lisätiedot, joita tarvitaan paikallisen sisällön kirjaamiseksi tai yhtenäistämiseksi muiden viitemallien tai formalismien kanssa.</items>
        <items id="comment">For example: local information requirements or additional metadata to align with FHIR or CIMI equivalents.</items>
      </items>
      <items code="at1057">
        <items id="text">Kliininen tulkinta</items>
        <items id="description">Yleinen otsikko, jonka alle voidaan kirjata jokin tai kaikki lausunnot pulssista tai sykkeestä.</items>
      </items>
      <items code="at1058">
        <items id="text">Rytmi</items>
        <items id="description">Nimenomainen johtopäätös pulssin tai sykkeen rytmistä, perustuu sykkeeseen, sykkeen ominaisuuksiin ja muihin tutkimuksessa havaittuihin ominaispiirteisiin.</items>
      </items>
      <items code="at1059">
        <items id="text">Kommentti</items>
        <items id="description">Pulssi- tai sykelöydösten kertomusmuodossa olevat lisätiedot, joita ei voida ilmoittaa muissa kentissä.</items>
      </items>
    </term_definitions>
    <term_definitions language="nb">
      <items code="at0000">
        <items id="text">Puls/Hjertefrekvens</items>
        <items id="description">Måling av puls/hjertefrekvens, eller eksplisitt puls eller hjertefrekvens, og beskrivelse av tilhørende egenskaper.</items>
      </items>
      <items code="at0001">
        <items id="text">structure</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0002">
        <items id="text">history</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0003">
        <items id="text">Uspesifisert hendelse</items>
        <items id="description">Standard, uspesifisert tidspunkt eller tidsintervall som kan defineres mer eksplisitt i en template eller i en applikasjon.</items>
      </items>
      <items code="at0004">
        <items id="text">Frekvens</items>
        <items id="description">Puls- eller hjertefrekvens, målt i støt/slag per minutt.</items>
        <items id="comment">Det er spesifisert begrensninger i navn for å gjøre det lettere å eksplisitt merke dette elementet som Pulsfrekvens eller Hjertefrekvens ved behov.</items>
      </items>
      <items code="at0005">
        <items id="text">Rytme</items>
        <items id="description">Observert regularitet av puls- eller hjerteslag.</items>
      </items>
      <items code="at0006">
        <items id="text">Regelmessig</items>
        <items id="description">Rytmen er regelmessig.</items>
      </items>
      <items code="at0007">
        <items id="text">Regelmessig uregelmessig</items>
        <items id="description">Rytmen er uregelmessig på en regelmessig måte.</items>
      </items>
      <items code="at0008">
        <items id="text">Uregelemessig uregelmessig</items>
        <items id="description">Mønsteret er uregelmessig på en kaotisk og ikkeforutsigbar måte. For eksempel, atrieflimmer.</items>
      </items>
      <items code="at0010">
        <items id="text">List</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0012">
        <items id="text">List</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0013">
        <items id="text">Stilling</items>
        <items id="description">Individets stilling ved tidspunktet for målingen.</items>
      </items>
      <items code="at1000">
        <items id="text">Liggende</items>
        <items id="description">Liggende flatt ved tidspunkt for målingen.</items>
      </items>
      <items code="at1001">
        <items id="text">Sittende</items>
        <items id="description">Sittende (for eksempel på en stol eller på en seng med føttene på gulvet) ved tidspunktet for målingen.</items>
      </items>
      <items code="at1002">
        <items id="text">Tilbakelent</items>
        <items id="description">Sittende tilbakelent ca 45º og med beina hevet til hoftehøyde ved tidspunkt for målingen.</items>
      </items>
      <items code="at1003">
        <items id="text">Stående</items>
        <items id="description">Stående, gående eller løpende ved tidspunktet for målingen.</items>
      </items>
      <items code="at1005">
        <items id="text">Tilstedeværelse</items>
        <items id="description">Tilstedeværelse av puls eller hjerteslag.</items>
        <items id="comment">Det er spesifisert begrensninger i navn for å gjøre det lettere å eksplisitt merke dette elementet som tilstedeværelse av Puls eller Hjertefrekvens ved behov.</items>
      </items>
      <items code="at1013">
        <items id="text">Måleapparat</items>
        <items id="description">Detaljer om måleapparatet brukt for å observere pulsen eller hjerteslagene.</items>
      </items>
      <items code="at1017">
        <items id="text">Fysisk anstrengelse</items>
        <items id="description">Detaljer om fysisk aktivitet på tidspunkt for målingen.</items>
      </items>
      <items code="at1018">
        <items id="text">Konfunderende faktorer</items>
        <items id="description">Tekstlig beskrivelse av eventuelle andre faktorer som kan påvirke tolkningen av funnene.</items>
        <items id="comment">Eksempel: pacemaker, nervøsitet, smerte, feber, gråt og annen uro, sedativa eller andre medikamenter.</items>
      </items>
      <items code="at1019">
        <items id="text">Målemetode</items>
        <items id="description">Metode brukt for å observere pulsen eller hjerteslagene.</items>
        <items id="comment">For eksempel palpasjon, auskultasjon eller elektronisk monitorering.</items>
      </items>
      <items code="at1022">
        <items id="text">Klinisk beskrivelse</items>
        <items id="description">Tekstlig beskrivelse av puls- eller hjerteslag.</items>
      </items>
      <items code="at1023">
        <items id="text">Klinisk tolkning</items>
        <items id="description">Kort beskrivelse av den kliniske betydningen av funnene.</items>
        <items id="comment">Koding med en terminologi er en fordel, hvis mulig. Eksempel: Bradykardi, ekstrasystoler, sinusrytme. Flere registreringer er tillatt.</items>
      </items>
      <items code="at1024">
        <items id="text">Tilstede</items>
        <items id="description">Puls eller hjerteslag finnes.</items>
      </items>
      <items code="at1025">
        <items id="text">Fraværende</items>
        <items id="description">Puls eller hjerteslag kan ikke finnes.</items>
      </items>
      <items code="at1028">
        <items id="text">Uregelmessig</items>
        <items id="description">Rytmen er uregelmessig.</items>
      </items>
      <items code="at1030">
        <items id="text">Karakter</items>
        <items id="description">Tekstlig beskrivelse av pulsens eller hjerteslag karakter.</items>
        <items id="comment">Koding med en terminologi er en fordel der det er mulig. Flere svar skal kunne registreres. Eksempler: Tydelig, svak, overfladisk.</items>
      </items>
      <items code="at1032">
        <items id="text">Palpasjon</items>
        <items id="description">Funnene observeres ved at observatøren med fingertuppene kjenner på pulsen eller hjerteslagene til individet.</items>
      </items>
      <items code="at1033">
        <items id="text">Auskultasjon</items>
        <items id="description">Funnene er observert ved hjelp av et hjelpemiddel som f.eks. et stetoskop.</items>
      </items>
      <items code="at1034">
        <items id="text">Automatisk, non-invasivt</items>
        <items id="description">Funnene er observert non-invasivt ved hjelp av en maskin, som f.eks. et pulsoksimeter eller et skop.</items>
      </items>
      <items code="at1036">
        <items id="text">Maksimum</items>
        <items id="description">Maksimumsfrekvens observert i løpet av et intervall med anstrengelse.</items>
      </items>
      <items code="at1037">
        <items id="text">Målested</items>
        <items id="description">Anatomisk sted hvor pulsen eller hjerteslagene ble observert.</items>
      </items>
      <items code="at1038">
        <items id="text">Radialisarterien, venstre</items>
        <items id="description">Den venstre radialisarterien.</items>
      </items>
      <items code="at1039">
        <items id="text">Radialisarterien, høyre</items>
        <items id="description">Den høyre radialisarterien.</items>
      </items>
      <items code="at1040">
        <items id="text">Hjertet</items>
        <items id="description">Hjerteregionen.</items>
      </items>
      <items code="at1041">
        <items id="text">Carotisarterien, venstre</items>
        <items id="description">Den venstre carotisarterien.</items>
      </items>
      <items code="at1042">
        <items id="text">Carotisarterien, høyre</items>
        <items id="description">Den høyre carotisarterien.</items>
      </items>
      <items code="at1043">
        <items id="text">Femoralisarterien, venstre</items>
        <items id="description">Den venstre femoralisarterien.</items>
      </items>
      <items code="at1044">
        <items id="text">Femoralisarterien, høyre</items>
        <items id="description">Den høyre femoralisarterien.</items>
      </items>
      <items code="at1047">
        <items id="text">Finger</items>
        <items id="description">En uspesifisert finger.</items>
      </items>
      <items code="at1048">
        <items id="text">Brachialisarterien, venstre</items>
        <items id="description">Den venstre brachialisarterien.</items>
      </items>
      <items code="at1049">
        <items id="text">Brachialisarterien, høyre</items>
        <items id="description">Den høyre brachialisarterien.</items>
      </items>
      <items code="at1050">
        <items id="text">Automatisk, invasivt</items>
        <items id="description">Funnene er observert invasivt ved hjelp av en maskin, som f.eks. et arteriekateter.</items>
      </items>
      <items code="at1051">
        <items id="text">Øreflipp</items>
        <items id="description">Øreflippen.</items>
      </items>
      <items code="at1054">
        <items id="text">Tå</items>
        <items id="description">En uspesifisert tå.</items>
      </items>
      <items code="at1055">
        <items id="text">Type uregelmessighet</items>
        <items id="description">Mer spesifikt mønster for en uregelmessig puls eller hjerteslag.</items>
        <items id="comment">Dette dataelementet er kun relevant dersom "Uregelmessig" er valgt fra dataelementet "Regelmessighet.</items>
      </items>
      <items code="at1056">
        <items id="text">Tilleggsinformasjon</items>
        <items id="description">Ytterligere informasjon som trengs for å kunne registrere lokalt definert innhold eller for å tilpasse til andre referansemodeller/formalismer.</items>
        <items id="comment">For eksempel lokale informasjonsbehov eller ytterligere metadata for å kunne tilpasse til tilsvarende konsepter i FHIR eller CIMI.</items>
      </items>
      <items code="at1057">
        <items id="text">Klinisk tolkning</items>
        <items id="description">Generisk elementnavn for å tillate øvrige eller alle utsagn om puls og hjerteslag.</items>
      </items>
      <items code="at1058">
        <items id="text">Rytme</items>
        <items id="description">Spesifik konklusjon om pulsrytme eller hjerteslag, hentet fra en kombinasjon av hjertefrekvens, mønster og andre karakteristika som observeres.</items>
      </items>
      <items code="at1059">
        <items id="text">Kommentar</items>
        <items id="description">Ytterligere fritekst om målingen som ikke er dekket av andre felt.</items>
      </items>
    </term_definitions>
    <term_definitions language="nl">
      <items code="at0000">
        <items id="text">Pols/Hartfrequentie</items>
        <items id="description">De frequentie en bijbehorende eigenschappen van de pols- of hartfrequentie.</items>
      </items>
      <items code="at0001">
        <items id="text">structure</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0002">
        <items id="text">history</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0003">
        <items id="text">Elke gebeurtenis</items>
        <items id="description">Standaard, ongespecificeerd punt in de tijd, of een interval dat gespecifieerd kan worden in een template of tijdens het lopen van de applicatie.</items>
      </items>
      <items code="at0004">
        <items id="text">Frequentie</items>
        <items id="description">De frequentie van pols- of hartslag, gemeten in slagen per minuut.</items>
      </items>
      <items code="at0005">
        <items id="text">Regulariteit.</items>
        <items id="description">Regulariteit van de pols- of hartslag.</items>
      </items>
      <items code="at0006">
        <items id="text">Regulair.</items>
        <items id="description">Het patroon is regulair.</items>
      </items>
      <items code="at0007">
        <items id="text">Regelmatig irregulair</items>
        <items id="description">Het patroon is onregelmatig in een regulair patroon. Bijvoorbeeld, een gemiste slag elke 'n' slagen.</items>
      </items>
      <items code="at0008">
        <items id="text">Onregelmatig irregulair.</items>
        <items id="description">Het patroon is onregelmatig op een chaotisch en onvoorspelbare manier. Bijvoorbeeld atrium fibrilleren.</items>
      </items>
      <items code="at0010">
        <items id="text">List</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0012">
        <items id="text">List</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0013">
        <items id="text">Houding</items>
        <items id="description">De lichaamshouding van de onderzochte tijdens de observatie.</items>
      </items>
      <items code="at1000">
        <items id="text">Liggend</items>
        <items id="description">De onderzochte lag plat.</items>
      </items>
      <items code="at1001">
        <items id="text">Zittend</items>
        <items id="description">De onderzochte zat (bijvoorbeeld op bed of in een stoel).</items>
      </items>
      <items code="at1002">
        <items id="text">Achteroverhellend</items>
        <items id="description">De onderzochte helde achterover in een hoek van ongeveer 45 graden, met de benen omhoog op het niveau van het bekken. Bijvoorbeeld in een bed of ligstoel.</items>
      </items>
      <items code="at1003">
        <items id="text">Staand/rechtop</items>
        <items id="description">De onderzochte stond, liep of was aan het rennen.</items>
      </items>
      <items code="at1005">
        <items id="text">Aanwezigheid</items>
        <items id="description">Aanwezigheid van een pols- of hartslag.</items>
        <items id="comment">Er mag afgeleid worden dat een pols- of hartslag aanwezig is bij frequentie van &gt;0/min.</items>
      </items>
      <items code="at1013">
        <items id="text">Apparaat</items>
        <items id="description">Details over het apparaat dat gebruikt is om de pols- of hartslag te meten.</items>
      </items>
      <items code="at1017">
        <items id="text">Inspanning</items>
        <items id="description">Details over de fysieke inspanning ondernomen tijdens het onderzoek.</items>
      </items>
      <items code="at1018">
        <items id="text">Beïnvloedende factoren</items>
        <items id="description">Verhalende beschrijving van incidentele factoren die de interpretatie van de bevindingen kan beïnvloeden.</items>
        <items id="comment">Bijvoorbeeld: aanwezigheid van een pacemaker, angst, pijn of koorts etc.</items>
      </items>
      <items code="at1019">
        <items id="text">Methode</items>
        <items id="description">De gebruikte methode voor het observeren van de pols- of hartslag.</items>
        <items id="comment">Bijvoorbeeld: auscultatie of elektronische monitoring.</items>
      </items>
      <items code="at1022">
        <items id="text">Klinische beschrijving</items>
        <items id="description">Verhalende beschrijving van de pols- of hartslag.</items>
      </items>
      <items code="at1023">
        <items id="text">Klinische interpretatie.</items>
        <items id="description">Een enkel woord, een uitdruking of een korte beschrijving die de klinische betekenis weergeeft van de gevonden pols- of hartslag, inclusief het ritme.</items>
        <items id="comment">Coderen met een terminologie verdient de voorkeur, waar mogelijk, Bijvoorbeeld: bradycard, extrasystolen of sinus ritme. Meerdere uitspraken toegestaan.</items>
      </items>
      <items code="at1024">
        <items id="text">Aanwezig</items>
        <items id="description">Een pols- of hartslag kan worden waargenomen.</items>
      </items>
      <items code="at1025">
        <items id="text">Niet waargenomen</items>
        <items id="description">Een pols- of hartslag kan niet worden waargenomen.</items>
      </items>
      <items code="at1028">
        <items id="text">Irregulair.</items>
        <items id="description">Het patroon is irregulair.</items>
      </items>
      <items code="at1030">
        <items id="text">Karakter</items>
        <items id="description">Beschrijving van het karakter van een pols- of hartslag.</items>
        <items id="comment">Coderen met een terminologie is gewenst, waar mogelijk. Bijvoorbeeld: vol, zwak, collaberend, 	&#xD;
traag stijgend of instortend. Er kunnen meerdere termen worden vastgelegd.</items>
      </items>
      <items code="at1032">
        <items id="text">Palpatie</items>
        <items id="description">De bevindingen werden geobserveerd middels fysieke aanraking door de onderzoeker van de onderzochte.</items>
      </items>
      <items code="at1033">
        <items id="text">Auscultatie</items>
        <items id="description">De bevindingen werden geobserveerd via een apparaat zoals een stethoscoop.</items>
      </items>
      <items code="at1034">
        <items id="text">Automatisch, noninvasief</items>
        <items id="description">De bevindingen zijn noninvasief geobserveerd met een apparaat zoals een pulsoximeter of een stethoscoop.</items>
      </items>
      <items code="at1036">
        <items id="text">Maximum</items>
        <items id="description">Maximum pols- of hartslag geobserveerd tijdens een periode van inspanning</items>
      </items>
      <items code="at1037">
        <items id="text">Lichaamslocatie</items>
        <items id="description">De lichaamslocatie waar de pols- of hartslag geobserveerd werden.</items>
      </items>
      <items code="at1038">
        <items id="text">Arteria radialis sinistra</items>
        <items id="description">De linker arteria radialis.</items>
      </items>
      <items code="at1039">
        <items id="text">Ateria radialis dextra</items>
        <items id="description">De rechter arteria radialis.</items>
      </items>
      <items code="at1040">
        <items id="text">Hart</items>
        <items id="description">De regio van het hart.</items>
      </items>
      <items code="at1041">
        <items id="text">Arteria carotis sinistra</items>
        <items id="description">De linker arteria carotis.</items>
      </items>
      <items code="at1042">
        <items id="text">Arteria carotis dextra</items>
        <items id="description">De rechter arteria carotis.</items>
      </items>
      <items code="at1043">
        <items id="text">Arteria femoralis sinistra</items>
        <items id="description">De linker arteria femoralis.</items>
      </items>
      <items code="at1044">
        <items id="text">Arteria femoralis dextra</items>
        <items id="description">De rechter arteria femoralis.</items>
      </items>
      <items code="at1047">
        <items id="text">Vinger</items>
        <items id="description">Een niet nader omschreven vinger.</items>
      </items>
      <items code="at1048">
        <items id="text">Arteria brachialis sinistra</items>
        <items id="description">De linker arteria brachialis.</items>
      </items>
      <items code="at1049">
        <items id="text">Arteria brachialis dextra</items>
        <items id="description">De rechter arteria brachialis.</items>
      </items>
      <items code="at1050">
        <items id="text">Automatisch, invasief</items>
        <items id="description">De bevindingen zijn invasief geobserveerd met een apparaat zoals een arteriele catheter.</items>
      </items>
      <items code="at1051">
        <items id="text">Oorlel</items>
        <items id="description">Het lelletje van een ongespecificeerd oor.</items>
      </items>
      <items code="at1054">
        <items id="text">Teen</items>
        <items id="description">Een niet nader omschreven vinger.</items>
      </items>
      <items code="at1055">
        <items id="text">Irregulair type.</items>
        <items id="description">Specifieker patroon van een irregulaire pols- of hartslag.</items>
        <items id="comment">Selectie van een waarde van deze codelijst is alleen valide indien 'irregulair' gekozen is bij het 'regulariteit' element.</items>
      </items>
      <items code="at1056">
        <items id="text">Uitbreiding</items>
        <items id="description">Extra informatie benodigd voor het vastleggen van lokale content of voor het verbinden met andere referentie modellen.</items>
        <items id="comment">Bijvoobeeld lokale informatiebehoefte of extra metadata om te verbinden met FHIR of CIMI.</items>
      </items>
      <items code="at1057">
        <items id="text">Klinische interpretatie</items>
        <items id="description">Algemeen label om uitspraken over de pols- of hartslag toe te staan.</items>
      </items>
      <items code="at1058">
        <items id="text">Ritme</items>
        <items id="description">Specifieke conclusies over het ritme van de pols- of hartslag, getrokken uit een combinatie van hartfrequentie, patroon en andere eigenschappen waargenomen bij onderzoek.</items>
      </items>
      <items code="at1059">
        <items id="text">Opmerking</items>
        <items id="description">Extra beschrijving van pols- of hartfrequentie bevindingen die niet passen binnen andere velden.</items>
      </items>
    </term_definitions>
    <term_definitions language="el">
      <items code="at0000">
        <items id="text">Παλμός/Καρδιακός παλμός</items>
        <items id="description">*The rate and associated attributes for a pulse or heart beat.(en)</items>
      </items>
      <items code="at0001">
        <items id="text">structure</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0002">
        <items id="text">history</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0003">
        <items id="text">*Any event(en)</items>
        <items id="description">*Default, unspecified point in time or interval event which may be explicitly defined in a template or at run-time.(en)</items>
      </items>
      <items code="at0004">
        <items id="text">Ρυθμός</items>
        <items id="description">*The rate of the pulse or heart beat, measured in beats per minute.(en)</items>
      </items>
      <items code="at0005">
        <items id="text">Κανονικότητα</items>
        <items id="description">*Regularity of the pulse or heart beat.(en)</items>
      </items>
      <items code="at0006">
        <items id="text">Τακτικός</items>
        <items id="description">*The pattern is regular.(en)</items>
      </items>
      <items code="at0007">
        <items id="text">Τακτικά ακανόνιστο</items>
        <items id="description">Το μοτίβο είναι ακανόνιστο σε κανονικό μοτίβο,. Για παράδειγμα, ένας ρυθμός που πέφτει μία φορά κάθε 'n' χτυπάει.</items>
      </items>
      <items code="at0008">
        <items id="text">Ακανόνιστα</items>
        <items id="description">Το μοτίβο είναι ακανόνιστο με χαοτικό και απρόβλεπτο τρόπο. Για παράδειγμα, κολπική μαρμαρυγή.</items>
      </items>
      <items code="at0010">
        <items id="text">List</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0012">
        <items id="text">List</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0013">
        <items id="text">Τοποθεσία</items>
        <items id="description">Η θέση του σώματος του υποκειμένου κατά τη διάρκεια της παρατήρησης.</items>
      </items>
      <items code="at1000">
        <items id="text">Ξαπλωμένη</items>
        <items id="description">*The subject was lying flat.(en)</items>
      </items>
      <items code="at1001">
        <items id="text">Καθιστή</items>
        <items id="description">*The subject was sitting (for example on bed or chair).(en)</items>
      </items>
      <items code="at1002">
        <items id="text">Σε ανάκλιση</items>
        <items id="description">*The subject was reclining at an approximate angle of 45 degrees, with the legs elevated to the level of the pelvis.(en)</items>
      </items>
      <items code="at1003">
        <items id="text">Ορθοστασία</items>
        <items id="description">*The subject was standing, walking or running.(en)</items>
      </items>
      <items code="at1005">
        <items id="text">Παρουσία</items>
        <items id="description">Παρουσία παλμού ή καρδιακού παλμού.</items>
        <items id="comment">Μπορεί να υπονοηθεί ότι ο παλμός ή ο καρδιακός παλμός είναι παρών εάν Ρυθμός &gt;0 / λεπτό.</items>
      </items>
      <items code="at1013">
        <items id="text">Συσκευή</items>
        <items id="description">Λεπτομέρειες σχετικά με τη συσκευή που χρησιμοποιείται για τη μέτρηση του παλμού ή του καρδιακού ρυθμού.</items>
      </items>
      <items code="at1017">
        <items id="text">Άσκηση</items>
        <items id="description">Λεπτομέρειες σχετικά με τη σωματική άσκηση που πραγματοποιείται κατά τη διάρκεια της εξέτασης.</items>
      </items>
      <items code="at1018">
        <items id="text">Συγχυτικοί παράγοντες</items>
        <items id="description">Αφηγηματική περιγραφή τυχόν τυχαίων παραγόντων που μπορεί να επηρεάσουν την ερμηνεία των φυσικών ευρημάτων.</items>
        <items id="comment">Για παράδειγμα, παρουσία βηματοδότη, επίπεδο άγχους. πόνος ή πυρετός κ. λπ.</items>
      </items>
      <items code="at1019">
        <items id="text">Μέθοδος</items>
        <items id="description">Μέθοδος που χρησιμοποιείται για την παρατήρηση του παλμού ή του καρδιακού παλμού.</items>
        <items id="comment">Για παράδειγμα, ακρόαση ή ηλεκτρονική παρακολούθηση.</items>
      </items>
      <items code="at1022">
        <items id="text">Κλινική Περιγραφή</items>
        <items id="description">Αφηγηματική περιγραφή σχετικά με τον παλμό ή τον καρδιακό παλμό.</items>
      </items>
      <items code="at1023">
        <items id="text">Κλινική ερμηνεία</items>
        <items id="description">Μία λέξη, φράση ή σύντομη περιγραφή που αντιπροσωπεύει την κλινική σημασία και σημασία των ευρημάτων παλμού ή καρδιακού παλμού, συμπεριλαμβανομένου του ρυθμού.</items>
        <items id="comment">Προτιμάται η κωδικοποίηση με ορολογία, όπου είναι δυνατόν. Για παράδειγμα: Βραδυκαρδία, Εξωσυστολές ή Φλεβοκομβικός ρυθμός. Επιτρέπονται πολλαπλές δηλώσεις.</items>
      </items>
      <items code="at1024">
        <items id="text">Παρών</items>
        <items id="description">Μπορεί να ανιχνευθεί παλμός ή καρδιακός παλμός.</items>
      </items>
      <items code="at1025">
        <items id="text">Δεν εντοπίστηκε</items>
        <items id="description">*A pulse or heart beat cannot be detected.(en)</items>
      </items>
      <items code="at1028">
        <items id="text">Ακανόνιστος</items>
        <items id="description">*The pattern is irregular.(en)</items>
      </items>
      <items code="at1030">
        <items id="text">Χαρακτηριστικό</items>
        <items id="description">Περιγραφή του χαρακτήρα του παλμού ή του καρδιακού παλμού.</items>
        <items id="comment">Η κωδικοποίηση με ορολογία είναι επιθυμητή, όπου είναι δυνατόν. Για παράδειγμα: πλήρης, με σπείρωμα, οριοθέτηση, αργή άνοδος ή σύμπτυξη. Μπορούν να καταγραφούν πολλαπλοί όροι.</items>
      </items>
      <items code="at1032">
        <items id="text">Ψηλάφιση</items>
        <items id="description">*The findings are observed by physical touch of the observer on the subject.(en)</items>
      </items>
      <items code="at1033">
        <items id="text">Ακρόαση</items>
        <items id="description">*The findings are observed with the assistance of a device, such as a stethoscope.(en)</items>
      </items>
      <items code="at1034">
        <items id="text">Αυτόματο , Μη επεμβατικό</items>
        <items id="description">*The findings are observed non-invasively using a device such as a pulse oximeter or a stethoscope.(en)</items>
      </items>
      <items code="at1036">
        <items id="text">Μέγιστο</items>
        <items id="description">*Maximum pulse rate or heart rate observed during a period of exertion.(en)</items>
      </items>
      <items code="at1037">
        <items id="text">Μέρος σώματος</items>
        <items id="description">*Body site where the pulse or heart beat were observed.(en)</items>
      </items>
      <items code="at1038">
        <items id="text">Κερκιδική αρτηρία - αριστερά</items>
        <items id="description">*The left radial artery.(en)</items>
      </items>
      <items code="at1039">
        <items id="text">Κερκιδική αρτηρία - Δεξιά</items>
        <items id="description">*The right radial artery.(en)</items>
      </items>
      <items code="at1040">
        <items id="text">Καρδιά</items>
        <items id="description">*The region of the heart.(en)</items>
      </items>
      <items code="at1041">
        <items id="text">Καρωτιδική αρτηρία - αριστερά</items>
        <items id="description">*The left carotid artery.(en)</items>
      </items>
      <items code="at1042">
        <items id="text">Καρωτίδα - Δεξιά</items>
        <items id="description">*The right carotid artery.(en)</items>
      </items>
      <items code="at1043">
        <items id="text">Μηριαία αρτηρία - Αριστερά</items>
        <items id="description">*The left femoral artery.(en)</items>
      </items>
      <items code="at1044">
        <items id="text">Μηριαία αρτηρία - Δεξιά</items>
        <items id="description">*The right femoral artery.(en)</items>
      </items>
      <items code="at1047">
        <items id="text">Δάχτυλο</items>
        <items id="description">*An unspecified finger.(en)</items>
      </items>
      <items code="at1048">
        <items id="text">Βραχιονική αρτηρία - Αριστερά</items>
        <items id="description">*The left brachial artery.(en)</items>
      </items>
      <items code="at1049">
        <items id="text">Βραχιονική αρτηρία - Δεξιά</items>
        <items id="description">*The right brachial artery.(en)</items>
      </items>
      <items code="at1050">
        <items id="text">Αυτόματο, επεμβατικό</items>
        <items id="description">*The findings are observed invasively using a device such as an arterial catheter.(en)</items>
      </items>
      <items code="at1051">
        <items id="text">Λοβός αυτιού</items>
        <items id="description">*The lobe of an unspecified ear.(en)</items>
      </items>
      <items code="at1054">
        <items id="text">Δάχτυλο ποδιού</items>
        <items id="description">*An unspecified toe.(en)</items>
      </items>
      <items code="at1055">
        <items id="text">Ακανόνιστος τύπος</items>
        <items id="description">Πιο συγκεκριμένο μοτίβο ακανόνιστου παλμού ή καρδιακού ρυθμού.</items>
        <items id="comment">Η επιλογή μιας τιμής από αυτό το σύνολο τιμών είναι έγκυρη μόνο εάν έχει επιλεγεί «Ακανόνιστη» από το στοιχείο δεδομένων «Κανονικότητα».</items>
      </items>
      <items code="at1056">
        <items id="text">*Extension(en)</items>
        <items id="description">*Additional information required to capture local content or to align with other reference models/formalisms.(en)</items>
      </items>
      <items code="at1057">
        <items id="text">Κλινική ερμηνεία</items>
        <items id="description">Γενική ετικέτα που επιτρέπει οποιαδήποτε ή όλες τις δηλώσεις σχετικά με τον παλμό ή τον καρδιακό παλμό.</items>
      </items>
      <items code="at1058">
        <items id="text">Ρυθμός</items>
        <items id="description">Ειδικό συμπέρασμα σχετικά με το ρυθμό του παλμού ή του καρδιακού παλμού, που αντλείται από ένα συνδυασμό του καρδιακού ρυθμού, του προτύπου και άλλων χαρακτηριστικών που παρατηρήθηκαν κατά την εξέταση.</items>
      </items>
      <items code="at1059">
        <items id="text">Σχόλιο</items>
        <items id="description">*Additional narrative about the pulse or heart beat findings not captured in other fields.(en)</items>
      </items>
    </term_definitions>
    <term_definitions language="zh-cn">
      <items code="at0000">
        <items id="text">脉搏/心跳</items>
        <items id="description">脉搏或心跳的速率以及相关的特征属性/特性/属性。</items>
      </items>
      <items code="at0001">
        <items id="text">structure</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0002">
        <items id="text">history</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0003">
        <items id="text">任何事件</items>
        <items id="description">可在模板之中或运行时明确定义的默认的、未明确指定的时间点型/时间型或时间区间型/时间间隔型事件。</items>
      </items>
      <items code="at0004">
        <items id="text">速率</items>
        <items id="description">脉搏或心跳的速率，且以每分钟脉搏搏动或心脏跳动的次数为单位。完整的名称分别为脉搏[速]率或心率</items>
      </items>
      <items code="at0005">
        <items id="text">规律性</items>
        <items id="description">脉搏或心跳的规律性。</items>
      </items>
      <items code="at0006">
        <items id="text">规律</items>
        <items id="description">脉搏或心跳的变化模式规律齐整。</items>
      </items>
      <items code="at0007">
        <items id="text">规律性不齐</items>
        <items id="description">模式属于是规律齐整的不齐/不规则。例如，每 'n' 次心跳会出现一次心跳脱漏（dropped beat）。</items>
      </items>
      <items code="at0008">
        <items id="text">不规律性不齐</items>
        <items id="description">模式不规则，混乱/杂乱且不可预测。例如，心房颤动（房颤）。</items>
      </items>
      <items code="at0010">
        <items id="text">List</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0012">
        <items id="text">List</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0013">
        <items id="text">体位</items>
        <items id="description">观察期间服务/记录对象（患者）的体位/身体姿势。</items>
      </items>
      <items code="at1000">
        <items id="text">平卧位</items>
        <items id="description">服务/记录对象（患者）当时的体位为平卧/平躺。</items>
      </items>
      <items code="at1001">
        <items id="text">坐位</items>
        <items id="description">服务/记录对象（患者）当时的体位为坐位/坐姿（如坐着床上或椅子上）。</items>
      </items>
      <items code="at1002">
        <items id="text">倾斜位</items>
        <items id="description">服务/记录对象（患者）当时的体位是角度大约 45 度的身体倾斜，且双腿抬高至骨盆水平。</items>
      </items>
      <items code="at1003">
        <items id="text">站立位/直立位</items>
        <items id="description">服务/记录对象（患者）当时的体位为站立、行走或跑步。</items>
      </items>
      <items code="at1005">
        <items id="text">存在情况</items>
        <items id="description">脉搏或心跳的存在情况或者说存在与否。</items>
        <items id="comment">如果脉搏[速]率或心率 &gt; 0 /min，则可能暗示着存在脉搏或心跳。</items>
      </items>
      <items code="at1013">
        <items id="text">设备</items>
        <items id="description">关于用来测量脉搏率或心率的设备/装置的详细信息。</items>
      </items>
      <items code="at1017">
        <items id="text">体力消耗</items>
        <items id="description">关于检查期间所进行的体力消耗/用力[动作]的详细信息。</items>
      </items>
      <items code="at1018">
        <items id="text">干扰因素</items>
        <items id="description">关于任何可能影响体格检查所见/结果解释的偶然因素的叙述性描述。又可称为“混杂因素”。</items>
        <items id="comment">例如，存在起搏器、焦虑程度、疼痛或发烧等等。</items>
      </items>
      <items code="at1019">
        <items id="text">方法</items>
        <items id="description">用于观察/测量/检测脉搏或心跳的方法。</items>
        <items id="comment">例如，听诊或电子监测。</items>
      </items>
      <items code="at1022">
        <items id="text">临床描述</items>
        <items id="description">关于脉搏或心跳的叙述性描述。</items>
      </items>
      <items code="at1023">
        <items id="text">临床解释</items>
        <items id="description">用来表示脉搏或心跳结果（包括心律/节律）的临床含义和意义的单个单词、短语或简要描述。</items>
        <items id="comment">尽可能采用术语标准来进行编码。例如：心动过缓（Bradycardia）、期外收缩（Extrasystoles）或窦性心律（Sinus rhythm）。允许同时采用多项陈述或者说多条术语。</items>
      </items>
      <items code="at1024">
        <items id="text">存在</items>
        <items id="description">可以检测到脉搏或心跳。</items>
      </items>
      <items code="at1025">
        <items id="text">未检测到</items>
        <items id="description">无法检测到脉搏或心跳。</items>
      </items>
      <items code="at1028">
        <items id="text">不规律</items>
        <items id="description">脉搏或心跳的变化模式不规律/不齐整。</items>
      </items>
      <items code="at1030">
        <items id="text">特征</items>
        <items id="description">关于脉搏或心跳特征/特点的描述。</items>
        <items id="comment">尽可能采用术语标准来进行编码。例如：完整（full）、细小（thready）、跳跃性（bounding）、缓慢升高（slow rising）或 衰退（collapsing）。可以同时采用多条术语来记录。</items>
      </items>
      <items code="at1032">
        <items id="text">触诊</items>
        <items id="description">观察者通过触摸服务/记录对象（患者）的身体来获得检查所见/观察结果。</items>
      </items>
      <items code="at1033">
        <items id="text">听诊</items>
        <items id="description">在借助于听诊器等设备/装置的情况下来获得检查所见/观察结果。</items>
      </items>
      <items code="at1034">
        <items id="text">自动无创式</items>
        <items id="description">利用脉搏血氧仪或听诊器等设备/装置进行无创式/非侵入式的观察所获得的所见/发现/结果。</items>
      </items>
      <items code="at1036">
        <items id="text">最大值</items>
        <items id="description">关于特定的体力消耗/用力[动作]期间所观察到的最大脉搏[速]率或心率。</items>
      </items>
      <items code="at1037">
        <items id="text">身体部位</items>
        <items id="description">观察脉搏或心跳时所采用的身体部位。</items>
      </items>
      <items code="at1038">
        <items id="text">桡动脉 - 左侧</items>
        <items id="description">左侧桡动脉。</items>
      </items>
      <items code="at1039">
        <items id="text">桡动脉 - 右侧</items>
        <items id="description">右侧桡动脉。</items>
      </items>
      <items code="at1040">
        <items id="text">心脏</items>
        <items id="description">心脏区域。</items>
      </items>
      <items code="at1041">
        <items id="text">颈动脉 - 左侧</items>
        <items id="description">左侧颈动脉。</items>
      </items>
      <items code="at1042">
        <items id="text">颈动脉 - 右侧</items>
        <items id="description">右侧颈动脉。</items>
      </items>
      <items code="at1043">
        <items id="text">股动脉 - 左侧</items>
        <items id="description">左侧股动脉。</items>
      </items>
      <items code="at1044">
        <items id="text">股动脉 - 右侧</items>
        <items id="description">右侧股动脉。</items>
      </items>
      <items code="at1047">
        <items id="text">手指</items>
        <items id="description">未明确说明的手指。</items>
      </items>
      <items code="at1048">
        <items id="text">肱动脉 - 左侧</items>
        <items id="description">左侧肱动脉。</items>
      </items>
      <items code="at1049">
        <items id="text">肱动脉 - 右侧</items>
        <items id="description">右侧肱动脉。</items>
      </items>
      <items code="at1050">
        <items id="text">自动有创式</items>
        <items id="description">利用动脉导管等设备/装置进行有创式/侵入式的观察所获得的所见/发现/结果。</items>
      </items>
      <items code="at1051">
        <items id="text">耳垂</items>
        <items id="description">未明确说明的耳朵的耳垂。</items>
      </items>
      <items code="at1054">
        <items id="text">脚趾</items>
        <items id="description">未明确说明的脚趾。</items>
      </items>
      <items code="at1055">
        <items id="text">不齐类型</items>
        <items id="description">不规则的脉搏或心跳的更为具体的模式。</items>
        <items id="comment">只有当从规律性数据元“Regularity”之中选择了取值“不规律” （Irregular）时，才能合理有效地选择本取值集合当中的取值。</items>
      </items>
      <items code="at1056">
        <items id="text">扩展</items>
        <items id="description">采集本地内容或与其他参考模型/形式保持一致时所需的其他信息。</items>
        <items id="comment">例如：本地信息要求，或者是与 FHIR 等效项保持一致时所需的其他元数据。</items>
      </items>
      <items code="at1057">
        <items id="text">临床解释</items>
        <items id="description">通用标签，旨在用于记录任何或所有关于脉搏或心跳的陈述。</items>
      </items>
      <items code="at1058">
        <items id="text">节律</items>
        <items id="description">关于脉搏或心跳节律的具体结论，而其依据则是相应的心率、模式以及检查时所观察到的其他特征的组合。</items>
      </items>
      <items code="at1059">
        <items id="text">备注</items>
        <items id="description">其他字段当中并未采集/记录的关于脉搏或心跳所见/发现的附加叙述。</items>
      </items>
    </term_definitions>
    <term_definitions language="ca">
      <items code="at0000">
        <items id="text">Pols / Batec cardíac</items>
        <items id="description">La freqüència i els atributs associats per a un pols o batec cardíac.</items>
      </items>
      <items code="at0001">
        <items id="text">estructura</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0002">
        <items id="text">història</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0003">
        <items id="text">Qualsevol esdeveniment</items>
        <items id="description">Per defecte, un punt no especificat en l'esdeveniment de temps o interval que es pot definir explícitament en una plantilla o en temps d'execució.</items>
      </items>
      <items code="at0004">
        <items id="text">Taxa</items>
        <items id="description">La velocitat del pols o batec del cor, mesurada en batecs per minut.</items>
      </items>
      <items code="at0005">
        <items id="text">Regularitat</items>
        <items id="description">Regularitat del pols o batec cardíac.</items>
      </items>
      <items code="at0006">
        <items id="text">Regular</items>
        <items id="description">El patró és regular.</items>
      </items>
      <items code="at0007">
        <items id="text">Regularment irregular</items>
        <items id="description">El patró és irregular en un patró regular. Per exemple, un batec caigut una vegada que cada 'n' batega.</items>
      </items>
      <items code="at0008">
        <items id="text">Irregular</items>
        <items id="description">El patró és irregular de manera caòtica i impredictible. Per exemple, la fibril·lació auricular.</items>
      </items>
      <items code="at0010">
        <items id="text">Llista</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0012">
        <items id="text">Llista</items>
        <items id="description">@ internal @</items>
      </items>
      <items code="at0013">
        <items id="text">Posició</items>
        <items id="description">La posició corporal del subjecte durant l'observació.</items>
      </items>
      <items code="at1000">
        <items id="text">mentida</items>
        <items id="description">El tema estava estirat.</items>
      </items>
      <items code="at1001">
        <items id="text">Assegut</items>
        <items id="description">El tema estava assegut (per exemple en llit o cadira).</items>
      </items>
      <items code="at1002">
        <items id="text">Reclinació</items>
        <items id="description">El tema estava reclinat en un angle aproximat de 45 graus, amb les cames elevades al nivell de la pelvis.</items>
      </items>
      <items code="at1003">
        <items id="text">En peu/alt</items>
        <items id="description">El tema estava de peu, caminant o corrent.</items>
      </items>
      <items code="at1005">
        <items id="text">Presència</items>
        <items id="description">Presència d'un pols o batec cardíac.</items>
        <items id="comment">Es pot implicar que el pols o batec cardíac està present si Tarifa the0 /min.</items>
      </items>
      <items code="at1013">
        <items id="text">Dispositiu</items>
        <items id="description">Detalls sobre el dispositiu utilitzat per mesurar la freqüència de pols o freqüència cardíaca.</items>
      </items>
      <items code="at1017">
        <items id="text">Exerció</items>
        <items id="description">Detalls sobre l'esforç físic que s'està realitzant durant l'examen.</items>
      </items>
      <items code="at1018">
        <items id="text">Factors de confusió</items>
        <items id="description">Descripció narrativa sobre qualsevol factor incidental que pugui afectar la interpretació de les troballes físiques.</items>
        <items id="comment">Per exemple, presència d'un marcapassos, nivell d'ansietat; dolor o febre, etc.</items>
      </items>
      <items code="at1019">
        <items id="text">Mètode</items>
        <items id="description">Mètode utilitzat per observar el pols o batec cardíac.</items>
        <items id="comment">Per exemple, l'auscultació o el monitoratge electrònic.</items>
      </items>
      <items code="at1022">
        <items id="text">Descripció clínica</items>
        <items id="description">Descripció narrativa sobre el pols o batec cardíac.</items>
      </items>
      <items code="at1023">
        <items id="text">Interpretació clínica</items>
        <items id="description">Paraula única, frase o breu descripció que representa el significat clínic i la significació de les troballes del pols o del batec cardíac, inclòs el ritme.</items>
        <items id="comment">Es prefereix la codificació amb una terminologia, sempre que sigui possible. Per exemple: Bradycardia, Extrasystoles o Sinus rhythm. Es permeten múltiples declaracions.</items>
      </items>
      <items code="at1024">
        <items id="text">Present</items>
        <items id="description">Es pot detectar un pols o batec cardíac.</items>
      </items>
      <items code="at1025">
        <items id="text">No detectat</items>
        <items id="description">No es pot detectar un pols o batec cardíac.</items>
      </items>
      <items code="at1028">
        <items id="text">Irregular</items>
        <items id="description">El patró és irregular.</items>
      </items>
      <items code="at1030">
        <items id="text">Caràcter</items>
        <items id="description">Descripció del caràcter del pols o batec cardíac.</items>
        <items id="comment">Es prefereix la codificació amb una terminologia, sempre que sigui possible. Per exemple: ple, filós, delimitador, lent ascendent o col·lapsant. Es poden registrar múltiples termes.</items>
      </items>
      <items code="at1032">
        <items id="text">Palpació</items>
        <items id="description">Els resultats s'observen mitjançant el contacte físic de l'observador sobre el tema.</items>
      </items>
      <items code="at1033">
        <items id="text">Auscultació</items>
        <items id="description">Les troballes s'observen amb l'ajuda d'un dispositiu, com un estetoscopi.</items>
      </items>
      <items code="at1034">
        <items id="text">Automàtic, no invasiu</items>
        <items id="description">Els resultats s'observen de manera no invasiva utilitzant un dispositiu com un oxidant de pols o un estetoscopi.</items>
      </items>
      <items code="at1036">
        <items id="text">Màxim</items>
        <items id="description">Freqüència màxima de pols o freqüència cardíaca observada durant un període d'esforç.</items>
      </items>
      <items code="at1037">
        <items id="text">Lloc del cos</items>
        <items id="description">Lloc corporal on es va observar el pols o batec cardíac.</items>
      </items>
      <items code="at1038">
        <items id="text">Artèria radial - Esquerra</items>
        <items id="description">L'artèria radial esquerra.</items>
      </items>
      <items code="at1039">
        <items id="text">Artèria radial - Dreta</items>
        <items id="description">L'artèria radial dreta.</items>
      </items>
      <items code="at1040">
        <items id="text">Cor</items>
        <items id="description">La regió del cor.</items>
      </items>
      <items code="at1041">
        <items id="text">Artèria caròtida - Esquerra</items>
        <items id="description">L'artèria caròtida esquerra.</items>
      </items>
      <items code="at1042">
        <items id="text">Artèria caròtida - Dreta</items>
        <items id="description">L'artèria caròtida dreta.</items>
      </items>
      <items code="at1043">
        <items id="text">Artèria Femoral - Esquerra</items>
        <items id="description">L'artèria femoral esquerra.</items>
      </items>
      <items code="at1044">
        <items id="text">Artèria Femoral - Dreta</items>
        <items id="description">L'artèria femoral dreta.</items>
      </items>
      <items code="at1047">
        <items id="text">Dit</items>
        <items id="description">Un dit no especificat.</items>
      </items>
      <items code="at1048">
        <items id="text">Artèria braquial - Esquerra</items>
        <items id="description">L'artèria braquial esquerra.</items>
      </items>
      <items code="at1049">
        <items id="text">Artèria braquial - Dreta</items>
        <items id="description">L'artèria braquial dreta.</items>
      </items>
      <items code="at1050">
        <items id="text">Automàtic, invasiu</items>
        <items id="description">Els resultats s'observen de manera invasiva utilitzant un dispositiu com un catèter arterial.</items>
      </items>
      <items code="at1051">
        <items id="text">Lòbul de l'or</items>
        <items id="description">El lòbul d'una orella no especificada.</items>
      </items>
      <items code="at1054">
        <items id="text">To</items>
        <items id="description">Un dit del peu no especificat.</items>
      </items>
      <items code="at1055">
        <items id="text">Tipus irregular</items>
        <items id="description">Patró més específic d'un pols irregular o batec cardíac.</items>
        <items id="comment">La selecció d'un valor d'aquest conjunt de valors només és vàlida si se selecciona «Irregular» des de l'element de dades «Regularitat».</items>
      </items>
      <items code="at1056">
        <items id="text">Extensió</items>
        <items id="description">Informació addicional requerida per capturar contingut local o per alinear-se amb altres models de referència/formalismes.</items>
        <items id="comment">Per exemple: requisits d'informació local o metadades addicionals per alinear-se amb equivalents FHIR o CIMI.</items>
      </items>
      <items code="at1057">
        <items id="text">Interpretació clínica</items>
        <items id="description">Etiqueta genèrica per permetre qualsevol o totes les declaracions sobre el pols o el batec del cor.</items>
      </items>
      <items code="at1058">
        <items id="text">Rhythm</items>
        <items id="description">Conclusió específica sobre el ritme del pols o batec cardíac, extret d'una combinació de la freqüència cardíaca, patró i altres característiques observades en l'examen.</items>
      </items>
      <items code="at1059">
        <items id="text">Comentari</items>
        <items id="description">Narrativa addicional sobre els resultats del pols o del batec cardíac no capturats en altres camps.</items>
      </items>
    </term_definitions>
  </ontology>
</archetype>
