All | OperationalTemplate [rootArchetypeId=openEHR-EHR-COMPOSITION.registereintrag.v1, otherContributors=Sarah Ballout, tshis=[ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1], code=at0000, itemType=COMPOSITION, level=0, text=Befund der Blutgasanalyse, description=Generic compilation to represent a data set for research purposes., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=COMPOSITION, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=null, code=null, itemType=UNSUPPORTEDTOPLEVELATTRIBUTE, level=1, text=Other Context, description=null, comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=UNSUPPORTEDTOPLEVELATTRIBUTE, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/context/other_context[at0001]/items[at0004], code=at0004, itemType=ELEMENT, level=2, text=Status, description=Status of the supplied data for the register entry. Note: This is not the status of individual components., comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=- registered
- preliminary
- final
- amended
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/context/other_context[at0001]/items[at0005], code=at0005, itemType=ELEMENT, level=2, text=Category, description=The classification of the register entry (e.g. type of observation of the FHIR profile)., comment=null, uncommonOntologyItems=null, occurencesFormal=1..*, occurencesText=Mandatory, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1], code=at0000, itemType=OBSERVATION, level=1, text=Laboratory test result, description=The result, including findings and the laboratory's interpretation, of an investigation performed on specimens collected from an individual or related to that individual., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=OBSERVATION, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001], code=at0001, itemType=UNSUPPORTEDTOPLEVELATTRIBUTE, level=2, text=Data, description=, comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=UNSUPPORTEDTOPLEVELATTRIBUTE, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001]/events[at0002], code=at0002, itemType=EVENT, level=3, text=Any event, description=Default, unspecified point in time or interval event which may be explicitly defined in a template or at run-time., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=EVENT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001]/events[at0002]/data[at0003], code=at0003, itemType=UNSUPPORTEDTOPLEVELATTRIBUTE, level=4, text=Data, description=, comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=UNSUPPORTEDTOPLEVELATTRIBUTE, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001]/events[at0002]/data[at0003]/items[at0005], code=at0005, itemType=ELEMENT, level=5, text=Test name, description=Name of the laboratory investigation performed on the specimen(s)., comment=A test result may be for a single analyte, or a group of items, including panel tests. It is strongly recommended that 'Test name' be coded with a terminology, for example LOINC or SNOMED CT. For example: 'Glucose', 'Urea and Electrolytes', 'Swab', 'Cortisol (am)', 'Potassium in perspiration' or 'Melanoma histopathology'. The name may sometimes include specimen type and patient state, for example 'Fasting blood glucose' or include other information, as 'Potassium (PNA blood gas)'., uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Mandatory, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values= Terminology: http://loinc.org- Gas panel - Blood
- Gas panel - Arterial blood
- Gas panel - Capillary blood
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001]/events[at0002]/data[at0003]/items[openEHR-EHR-CLUSTER.laboratory_test_analyte.v1 and name/value='Kohlendioxidpartialdruck'], code=at0000, itemType=CLUSTER, level=5, text=Kohlendioxidpartialdruck, description=The result of a laboratory test for a single analyte value., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001]/events[at0002]/data[at0003]/items[openEHR-EHR-CLUSTER.laboratory_test_analyte.v1 and name/value='Kohlendioxidpartialdruck']/items[at0024], code=at0024, itemType=ELEMENT, level=6, text=Analyte name, description=The name of the analyte result., comment=The value for this element is normally supplied in a specialisation, in a template or at run-time to reflect the actual analyte. For example: 'Serum sodium', 'Haemoglobin'. Coding with an external terminology is strongly recommended, such as LOINC, NPU, SNOMED CT, or local lab terminologies., uncommonOntologyItems={fhir_mapping=Observation.code, hl7v2_mapping=OBX.3}, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values= Terminology: http://loinc.org Value set: terminology://fhir.hl7.org/ValueSet/$expand?url=https://www.netzwerk-universitaetsmedizin.de/fhir/ValueSet/blood-gas-analysis-pco2- 2019-8 | Carbon dioxide [Partial pressure] in Arterial blood
- 11557-6 | Carbon dioxide [Partial pressure] in Blood
- 2020-6 | Carbon dioxide [Partial pressure] in Capillary blood
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001]/events[at0002]/data[at0003]/items[openEHR-EHR-CLUSTER.laboratory_test_analyte.v1 and name/value='Kohlendioxidpartialdruck']/items[at0001], code=at0001, itemType=ELEMENT, level=6, text=Analyte result, description=The value of the analyte result., comment=For example '7.3 mmol/l', 'Raised'. The 'Any' data type will need to be constrained to an appropriate data type in a specialisation, a template or at run-time to reflect the actual analyte result. The Quantity data type has reference model attributes that include flags for normal/abnormal, reference ranges and approximations - see https://specifications.openehr.org/releases/RM/latest/data_types.html#_dv_quantity_class for more details., uncommonOntologyItems={fhir_mapping=Observation.value[x], hl7v2_mapping=OBX.2, OBX.5, OBX.6, OBX.7, OBX.8}, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_QUANTITY, bindings=null, values=Units: mmHg, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001]/events[at0002]/data[at0003]/items[openEHR-EHR-CLUSTER.laboratory_test_analyte.v1 and name/value='Kohlendioxidpartialdruck']/items[at0005], code=at0005, itemType=ELEMENT, level=6, text=Result status, description=The status of the analyte result value., comment=The values have been specifically chosen to match those in the HL7 FHIR Diagnostic report, historically derived from HL7v2 practice. Other local codes/terms can be used via the Text 'choice'.
This element allows multiple occurrences to support use cases where more than one type of status need to be implemented., uncommonOntologyItems={fhir_mapping=Observation.status, hl7v2_mapping=OBX.11}, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=- registriert
- vorläufig
- final
- geändert
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001]/events[at0002]/data[at0003]/items[openEHR-EHR-CLUSTER.laboratory_test_analyte.v1 and name/value='Sauerstoffpartialdruck'], code=at0000, itemType=CLUSTER, level=5, text=Sauerstoffpartialdruck, description=The result of a laboratory test for a single analyte value., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001]/events[at0002]/data[at0003]/items[openEHR-EHR-CLUSTER.laboratory_test_analyte.v1 and name/value='Sauerstoffpartialdruck']/items[at0024], code=at0024, itemType=ELEMENT, level=6, text=Analyte name, description=The name of the analyte result., comment=The value for this element is normally supplied in a specialisation, in a template or at run-time to reflect the actual analyte. For example: 'Serum sodium', 'Haemoglobin'. Coding with an external terminology is strongly recommended, such as LOINC, NPU, SNOMED CT, or local lab terminologies., uncommonOntologyItems={fhir_mapping=Observation.code, hl7v2_mapping=OBX.3}, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values= Terminology: http://loinc.org Value set: terminology://fhir.hl7.org/ValueSet/$expand?url=https://www.netzwerk-universitaetsmedizin.de/fhir/ValueSet/blood-gas-analysis-po2- 2703-7 | Oxygen [Partial pressure] in Arterial blood
- 11556-8 | Oxygen [Partial pressure] in Blood
- 2704-5 | Oxygen [Partial pressure] in Capillary blood
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001]/events[at0002]/data[at0003]/items[openEHR-EHR-CLUSTER.laboratory_test_analyte.v1 and name/value='Sauerstoffpartialdruck']/items[at0001], code=at0001, itemType=ELEMENT, level=6, text=Analyte result, description=The value of the analyte result., comment=For example '7.3 mmol/l', 'Raised'. The 'Any' data type will need to be constrained to an appropriate data type in a specialisation, a template or at run-time to reflect the actual analyte result. The Quantity data type has reference model attributes that include flags for normal/abnormal, reference ranges and approximations - see https://specifications.openehr.org/releases/RM/latest/data_types.html#_dv_quantity_class for more details., uncommonOntologyItems={fhir_mapping=Observation.value[x], hl7v2_mapping=OBX.2, OBX.5, OBX.6, OBX.7, OBX.8}, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_QUANTITY, bindings=null, values=Units: mmHg, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001]/events[at0002]/data[at0003]/items[openEHR-EHR-CLUSTER.laboratory_test_analyte.v1 and name/value='Sauerstoffpartialdruck']/items[at0005], code=at0005, itemType=ELEMENT, level=6, text=Result status, description=The status of the analyte result value., comment=The values have been specifically chosen to match those in the HL7 FHIR Diagnostic report, historically derived from HL7v2 practice. Other local codes/terms can be used via the Text 'choice'.
This element allows multiple occurrences to support use cases where more than one type of status need to be implemented., uncommonOntologyItems={fhir_mapping=Observation.status, hl7v2_mapping=OBX.11}, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=- registered
- preliminary
- final
- amended
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001]/events[at0002]/data[at0003]/items[openEHR-EHR-CLUSTER.laboratory_test_analyte.v1 and name/value='pH-Wert'], code=at0000, itemType=CLUSTER, level=5, text=pH-Wert, description=The result of a laboratory test for a single analyte value., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001]/events[at0002]/data[at0003]/items[openEHR-EHR-CLUSTER.laboratory_test_analyte.v1 and name/value='pH-Wert']/items[at0024], code=at0024, itemType=ELEMENT, level=6, text=Analyte name, description=The name of the analyte result., comment=The value for this element is normally supplied in a specialisation, in a template or at run-time to reflect the actual analyte. For example: 'Serum sodium', 'Haemoglobin'. Coding with an external terminology is strongly recommended, such as LOINC, NPU, SNOMED CT, or local lab terminologies., uncommonOntologyItems={fhir_mapping=Observation.code, hl7v2_mapping=OBX.3}, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values= Terminology: http://loinc.org Value set: terminology://fhir.hl7.org/ValueSet/$expand?url=https://www.netzwerk-universitaetsmedizin.de/fhir/ValueSet/blood-gas-analysis-ph- 2753-2 | pH of Serum or Plasma
- 2746-6 | pH of Venous blood
- 2745-8 | pH of Capillary blood
- 2744-1 | pH of Arterial blood
- 19213-8 | pH of Mixed venous blood
- 11558-4 | pH of Blood
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001]/events[at0002]/data[at0003]/items[openEHR-EHR-CLUSTER.laboratory_test_analyte.v1 and name/value='pH-Wert']/items[at0001], code=at0001, itemType=ELEMENT, level=6, text=Analyte result, description=The value of the analyte result., comment=For example '7.3 mmol/l', 'Raised'. The 'Any' data type will need to be constrained to an appropriate data type in a specialisation, a template or at run-time to reflect the actual analyte result. The Quantity data type has reference model attributes that include flags for normal/abnormal, reference ranges and approximations - see https://specifications.openehr.org/releases/RM/latest/data_types.html#_dv_quantity_class for more details., uncommonOntologyItems={fhir_mapping=Observation.value[x], hl7v2_mapping=OBX.2, OBX.5, OBX.6, OBX.7, OBX.8}, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_QUANTITY, bindings=null, values=Units: pH, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001]/events[at0002]/data[at0003]/items[openEHR-EHR-CLUSTER.laboratory_test_analyte.v1 and name/value='pH-Wert']/items[at0005], code=at0005, itemType=ELEMENT, level=6, text=Result status, description=The status of the analyte result value., comment=The values have been specifically chosen to match those in the HL7 FHIR Diagnostic report, historically derived from HL7v2 practice. Other local codes/terms can be used via the Text 'choice'.
This element allows multiple occurrences to support use cases where more than one type of status need to be implemented., uncommonOntologyItems={fhir_mapping=Observation.status, hl7v2_mapping=OBX.11}, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=- registered
- preliminary
- final
- amended
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001]/events[at0002]/data[at0003]/items[openEHR-EHR-CLUSTER.laboratory_test_analyte.v1 and name/value='Sauerstoffsättigung'], code=at0000, itemType=CLUSTER, level=5, text=Sauerstoffsättigung, description=The result of a laboratory test for a single analyte value., comment=null, uncommonOntologyItems=null, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001]/events[at0002]/data[at0003]/items[openEHR-EHR-CLUSTER.laboratory_test_analyte.v1 and name/value='Sauerstoffsättigung']/items[at0024], code=at0024, itemType=ELEMENT, level=6, text=Analyte name, description=The name of the analyte result., comment=The value for this element is normally supplied in a specialisation, in a template or at run-time to reflect the actual analyte. For example: 'Serum sodium', 'Haemoglobin'. Coding with an external terminology is strongly recommended, such as LOINC, NPU, SNOMED CT, or local lab terminologies., uncommonOntologyItems={fhir_mapping=Observation.code, hl7v2_mapping=OBX.3}, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values= Terminology: http://loinc.org Value set: terminology://fhir.hl7.org/ValueSet/$expand?url=https://www.netzwerk-universitaetsmedizin.de/fhir/ValueSet/blood-gas-analysis-sO2- 2708-6 | Oxygen saturation in Arterial blood
- 20564-1 | Oxygen saturation in Blood
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001]/events[at0002]/data[at0003]/items[openEHR-EHR-CLUSTER.laboratory_test_analyte.v1 and name/value='Sauerstoffsättigung']/items[at0001], code=at0001, itemType=ELEMENT, level=6, text=Analyte result, description=The value of the analyte result., comment=For example '7.3 mmol/l', 'Raised'. The 'Any' data type will need to be constrained to an appropriate data type in a specialisation, a template or at run-time to reflect the actual analyte result. The Quantity data type has reference model attributes that include flags for normal/abnormal, reference ranges and approximations - see https://specifications.openehr.org/releases/RM/latest/data_types.html#_dv_quantity_class for more details., uncommonOntologyItems={fhir_mapping=Observation.value[x], hl7v2_mapping=OBX.2, OBX.5, OBX.6, OBX.7, OBX.8}, occurencesFormal=null, occurencesText=null, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_QUANTITY, bindings=null, values=Units: %, extendedValues=null], ResourceSimplifiedHierarchyItem [path=[openEHR-EHR-COMPOSITION.registereintrag.v1]/content[openEHR-EHR-OBSERVATION.laboratory_test_result.v1]/data[at0001]/events[at0002]/data[at0003]/items[openEHR-EHR-CLUSTER.laboratory_test_analyte.v1 and name/value='Sauerstoffsättigung']/items[at0005], code=at0005, itemType=ELEMENT, level=6, text=Result status, description=The status of the analyte result value., comment=The values have been specifically chosen to match those in the HL7 FHIR Diagnostic report, historically derived from HL7v2 practice. Other local codes/terms can be used via the Text 'choice'.
This element allows multiple occurrences to support use cases where more than one type of status need to be implemented., uncommonOntologyItems={fhir_mapping=Observation.status, hl7v2_mapping=OBX.11}, occurencesFormal=0..*, occurencesText=Optional, repeating, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=- registered
- preliminary
- final
- amended
, extendedValues=null]], templateType=normal] |